Loading…
Loading…
2,710 results • Best match
Providing DG Set, Inverter and Electrical Items for NABH Accreditation to Govt. Chest Hospital, Visakhapatnam in Visakhapatnam District
Providing DG Set, Inverter and Electrical Items for NABH Accreditation to Govt. Chest Hospital, Visakhapatnam in Visakhapatnam District
Providing DG Set, Inverter and Electrical Items for NABH Accreditation to Govt. Chest Hospital, Visakhapatnam in Visakhapatnam District
Supply and Installation of SEMINAR HALL AIR CONDITIONERS INVERTER AC 2 Tons for the Department of Mechanical Engineering
Solar on grid Inverter Set for commercial on the top of the Residence of Vice-Chancellor, JNTUA, Ananthapuramu.
Supply and Installation of SEMINAR HALL AIR CONDITIONERS (INVERTER AC-2 Tons))for the Department of Mechanical Engineering
Porividing Entrance CC Widening Railing, Plants and inverter with Batteries for Anna Canteen in 12th ward, Peddapuram Municipality
Supply of inverters to the various temples such as Sri pattabhiramaswamy temple, Valmikipuram, Sri Konetirayswamy temmple, Keelapatla, Sri Prasanna Venkateswara swamy temple, Kosuvaripalli, Sri Lakshmi Narasimhaswamy temple, Chandragiri in SKVST section, Chittoor district of ESD-SBH, Tirupati.
Providing of 10 KVA Inverters with necessary electrical wiring work for uninterrupted power supply to the Laddu counters, Command control room in PAC-4, Nandakam, KKC, Main KKC ticket issue hall and Kalyanavedika at ESD-North,Tirumala
1.SUPPLY AND COMMISSIONING OF 230 VOLTS, 200 AMPS 5 KVA INVERTER MODEL SINGLE PHASE INVERTER BASED WELDING PLANT WITH VRD FEATURE AS PER THE SPECIFICATIONS EENCLOSED IN ANNEXURE-A. 2.Supply and commisioning of Portable 200Amps 230V single phase ... phase inverter based ... KVA INVERTER MODEL, ... PHASE INVERTER BASED ...
Online UPS Online UPS ( 3 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 2.0 KVA As per GeM Catalogue. Technology IGBT-PWM with inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer, IGBT- PWM with inbuilt isolation transformer, IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave, 50Hz single phase 160V - 260V sinewave, 50Hz, Three phase 300 V - 450V sinewave, 50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz, 3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 120 15, 30, 60, 90, 120, 180, 240 Minimum VAH (VAH) 6400 Warranty for UPS (Years) 2 1, 2, 3, 4, 5 Movable trolly for Batteries Without trollery but with rack With, Without, Without trollery but 1/4 with rack Warranty for battery 2 1, 2 Degree of Protection IP20 IP21, IP20 Cabling 5 meters for input and out put With With, Without Paralleling kit for synchronising With With, Without Installation and Commissioning Yes - CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 - Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I, II&III) - FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 - Voltage Regulation from no load to full load (%) /= 3% - 20% Overload limit for minimum 10 minutes Yes - Overall Efficiency (%) >/=90% - Total Harmonic Distortion(THD) (%) Maximum 3% - 50% Overload limit for minimum 1 minutes Yes - PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes - Protection of Over voltage, Short Circuit & over load at UPS output terminal Yes - METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage, Output AC Volt age, Current, Frequency, Battery Voltage and Current Yes - Indicators for mains presence, Battery charging and discharging, Output Over Load, Low Battery Voltage Yes - REPORTS AND Damp Heat : in Yes - 2/4 CERTIFICATION accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C, two cycles of (12+12) hours each 2007) Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes - Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes - Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes - Type Test Certificate No. NTH(SR)/EL(C)/2017/00 413B - Type Test Certificate date 02.12.2017 - Name of Lab NATIONAL TEST HOUSE - Address of Lab TARAMANI, CHENNAI - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Devarapati Ramanaiah 534201, O/o SSPOs Bhimavaram 3 15
All in One PC (V2) (Q2), Online UPS (V2) (Q2) (3 (3 ))
Supply and installation of UPS system for the work of Providing Electrical installations to modification of VQC-II old Luggage deposit centre as CCTV control room in ESD-West, Tirumala(Part-B)
S,I,T,C of Smart lighting LED fixtures for the work of Providing of smart lighting,AC units, UPS system to Annamaiah Bhavan meeting hall in ESD-South,Tirumala(Part-A)
Supply, installation, testing and commissioning of 3ph, 400V, 120 KVA Monolithic UPS with Modular Architecture in parallel redundancy mode by using existing condition batteries in place of existing 2nos. 160 KVA UPS with buy back at Data center, Corporate office, APSPDCL, Tirupati.
Supply of battery chargers and ARD batteries to the 16 passengers Lift of Jhonson make available in TTD Admn.Building in ESD-II,Tirupati for the year 2018-19.(Part-B)
Selection of Agency for Supply and Installation of UPS and Stabilizer
Design, manufacture, supply, erection, testing and commissioning of 1No. dual float cum boost charger as per enclosed techincal specifications and standards for 220V DC 400AH battery bank along with buyback of old charger at 220KV Switchyard of Srisailam Right Bank, Srisailam Project, Kurnool -518102, A.P..
Supply, installation, testing and commissioning of 220V (Ni- Cd) Battery Bank
Urgent repairs to the street lighting system and replacement of inverter batteries in the R&B Inspection Bungalow, Srikakulam.
Providing of Electrification, LED Down Lighter, and Inverter Model cool type split AC Unit of biodiversity centre in Kurnool.
Providing Pivot wall mounting fans (Inverter control AC Motor) to Unjal Mandapam inside of Sri Govindaraja swamy Temple Tirupati
AME for Temporary Illuminations, AMF Panels, APFC Panels, UPS system etc. in SV Temple at Kanyakumari in Tamilnadu State pertaining to AE-I section in ESD-III, Tirupati for the year 2026-27
SITC of LED Fixtures for the work of Providing AC Units, UPS System and smart LED lighting to the newly proposed conference hall and meeting hall in SV Vedic University, Tirupati. (Part-C)
SITC of AC Units for the work of Providing AC Units, UPS System and smart LED lighting to the newly proposed conference hall and meeting hall in SV Vedic University, Tirupati. (Part-A)
132kW Inverter rated SQIM for Cooling tower fan in CWP-5, SQIM 37KW 4P FOR CWP-4, 18.5 KW SQIM 4P FAC AOP MOTOR, 37kW SQIM 2P Chilled Water Pump motor in ASUs of ASP-1
SPL REPAIRS FOR REPLACEMENT OF OLD LT PANELS AND AIR CURTAINS AT TPW AREA INSIDE NAVAL DOCKYARD AND PROVN OF 60 KVA UPS FOR CAT-I APPROACH CIRCUIT I AND II FOR AIR FIELDS LIGHTING SYSTEM AT CCR, INS DEGA UNDER GE (U-I) VISAKHAPATNAM
Supply, Installation, Commissioning and Maintenance 150 Nos of 10 KVA UPS for all BC Welfare hostels of Andhra Pradesh (With Supply of 16 batteries, UPS with rating of 10 KVA with external battery module of capacity of 100AH) in the state of Andhra Pradesh
Supply, Installation, Commissioning and Maintenance 150 Nos of 10 KVA UPS for all BC Welfare hostels of Andhra Pradesh (With Supply of 16 batteries, UPS with rating of 10 KVA with external battery module of capacity of 100AH) in the state of Andhra Pradesh
Procurement, Install, Test and Commissioning of 11 Nos, 5 Star rated, inverter type, 1.5T Split AC units for Office Spaces.
Supply & Installation of 10 KVA lighting Inverter to Minikalyanakatta Halls in Cellar of Nandakam Rest House in ESD-North, Tirumala
Supply Delivery and Installation of 03Nos 2.0TR 5 Star Inverter Split Air Conditioner's in Administrative Section, Third Floor of RMC.
Supply and Installation of 7Nos of inverter units for use in the official residences of honorable judges of high court
Supply and fixing of New Solar Inverter at MEPMA office building in Vizianagaram Municipal Corporation. Est Cost Rs. 2.00 Lakhs.
Custom Bid for Services - Comprehensive Annual Maintenance contract of M/s Medha make 180KVA static inverters through OEM for a period of Three (03) years at Electric loco shed Vijayawada Similar Category Comprehensive Annual Maintenance Services for Precision Air Conditioners
Procurement of HBL NI_CD spare Battery cells for 24VDC Battery bankSystems at NTPC Kudgi
Online UPS Experience with Gov. Required 5 Year (s) Online UPS ( 16 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 1.0 KVA 1.0 KVA Technology MOSFET-PWM with inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer, IGBT- PWM with inbuilt isolation transformer, IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave, 50Hz single phase 160V - 260V sinewave, 50Hz, Three phase 300 V - 450V sinewave, 50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz, 3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 30 30 Minimum VAH (VAH) 800 1000, 1100, 800 Warranty for UPS (Years) 2 1, 2, 3, 4, 5 1/4 Movable trolly for Batteries Without With, Without, Without trollery but with rack Warranty for battery 1 1, 2 Degree of Protection IP21 IP21, IP20 Cabling 5 meters for input and out put Without With, Without Paralleling kit for synchronising With With, Without Installation and Commissioning Yes - CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 - Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I, II&III) - FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 - Voltage Regulation from no load to full load (%) /= 3% - 20% Overload limit for minimum 10 minutes Yes - Overall Efficiency (%) >/=90% - Total Harmonic Distortion(THD) (%) Maximum 3% - 50% Overload limit for minimum 1 minutes Yes - PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes - Protection of Over voltage, Short Circuit & over load at UPS output terminal Yes - METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage, Output AC Volt age, Current, Frequency, Battery Voltage and Current Yes - Indicators for mains presence, Battery charging and discharging, Output Over Load, Low Battery Yes - 2/4 Voltage REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C, two cycles of (12+12) hours each 2007) Yes - Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes - Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes - Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes - Type Test Certificate No. ISO 9000 - 2000 - Type Test Certificate date ISO 9000 - 2000 - Name of Lab ISO Pune - Address of Lab ISO Pune - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Not applicable presently - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Pradeep Khanna 531163, INS KALINGA 16 15
Portable Single Phase Welding Machine, IGBT Inverter Type, 200 Amps output current range as per the specifications mentioned in Annexure I
Supply & Installation of 5.0KVA Inverter with wing to the Office of Dy.EE(Civil) sub-division at Rajahmundry in East Godavari district
Providing Renovation and Repairs works Plumbing, Pannelling, Inverter and other works to Anna Canteen in Ward No.5 in Nagari Municipality
Replacement of Air conditioner in the Superintending Engineer chamber and Inverter in the R&B Circle office ,Srikakulam in Srikakulam District.
Supply and Installation of 3 feet dia Pivot Wall mounting fans (Inverter control A.C.Motor) to Nadaneerajanam stage & inside of Sri.TT, Tirumala
Supply & Installation of 5.0KVA Inverter with wing to the Office of Dy.EE(Civil) sub-division at Rajahmundry in East Godavari district
Portable Single Phase Welding Machine, IGBT Inverter Type, 200 Amps output current range as per the specifications mentioned in Annexure I
Procurement of PCs, Multi functional printer, One Kva Ups, L3 Switch (Q3)
Supply, Installation, Commissioning and Maintenance of 10 KVA UPS for all BC schools and BC Welfare hostels of Andhra Pradesh (With Supply of20 batteries, UPS with rating of 10 KVA with external battery module of capacity of 150 AH/12 volts) in the state of A.P
Supply, Installation, Commissioning and Maintenance of 10 KVA UPS for all BC schools and BC Welfare hostels of Andhra Pradesh (With Supply of20 batteries, UPS with rating of 10 KVA with external battery module of capacity of 150 AH/12 volts) in the state of A.P
Supply of HBL/EXIDE/AMARA RAJA make 220V DC, 330AH, Nickel-Cadmium BATTERY BANK, C5, HIGH DISCHARGE PERFORMANCE, WITH VENT PLUG, INTER CELL CONNECTOR FASTENERS, DC CLAMP METER, WOODEN STILLAGE AND NUMBER PLATE WITH FIXING SCREWS IN DRY AND UNCHARGED CONDITION including Buy Back, Dismantling, Erection, Commissioning & Testing.
Supply of HBL/EXIDE/AMARA RAJA make 220V DC, 330AH, Nickel-Cadmium BATTERY BANK, C5, HIGH DISCHARGE PERFORMANCE, WITH VENT PLUG, INTER CELL CONNECTOR FASTENERS, DC CLAMP METER, WOODEN STILLAGE AND NUMBER PLATE WITH FIXING SCREWS IN DRY AND UNCHARGED CONDITION including Buy Back, Dismantling, Erection, Commissioning & Testing.
Customized AMC/CMC for Pre-owned Products - AMC FOR TWO 90 KVA 400HZ MOBILE TRAILER MOUNTED ROTARY FREQUENCY CONVERTORS AND TWO 200 KVA MOBILE TRAILER MOUNTED UPS SYSTEM; NEE LAB; Annual Maintenance Contract (AMC); DAILY; No