Loading…
Loading…
2,711 results • Best match
24V, 62.5A (1.5kw), Rectifier+ converter with integral DCDB, SMPS Based, Floor Mounted, 42 AH, 4 Blocks of 12 V SMF Battery ( Make Amara Raja/Excide/HBL), Supervision of I & C support for 6 working days in split of two visits of 3 days for each DC UPS
Emergency lighting and accessories (Portable Emergency Lighting System Tower type with Battery Bank) (Q3) MSE Exemption for Years Of Experience and Turnover Yes Startup Exemption for Years Of Experience and Turnover Yes Document required from seller OEM Authorization Certificate, Additional Doc 1 (Requested in ATC) *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer Do you want to show documents uploaded by bidders to all bidders participated in bid? No Bid to RA enabled Yes RA Qualification Rule 50% Lowest Priced Technically Qualified Bidders Type of Bid Two Packet Bid Bid Number ( ) : GEM/2024/B/5763974 Dated : 31-12-2024 Bid Document 1/7 Time allowed for Technical Clarifications during technical evaluation 2 Days Inspection Required (By Empanelled Inspection Authority/Agencies pre- registered with GeM) No Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Required No ePBG Detail Advisory Bank State Bank of India ePBG Percentage(%) (%) 3.00 Duration of ePBG required (Months) ( ) . 14 (a). EMD & Performance security should be in favour of Beneficiary, wherever it is applicable., Beneficiary : SENIOR ACCOUNTS OFFICER Finance & Accounts Division, Satish Dhawan Space Centre SHAR, Department of Space, indian space research organization, Department of Space (Senior Accounts Officer) MII Purchase Preference MII Purchase Preference No MSE Purchase Preference MSE Purchase Preference Yes 1. If the bidder is a Micro or Small Enterprise as per latest definitions under MSME rules, the bidder shall be exempted from the requirement of "Bidder Turnover" criteria and "Experience Criteria" subject to meeting of quality and technical specifications. If the bidder is OEM of the offered products, it would be exempted from the 2/7 "
Construction of 0.50 units Boys hostel, 0.5 units Girls hostel, Residential Quarters 27 Nos (Principal Residence - 1 No, Type ll -10 Nos, Type lll - 15 Nos, 1 No guest house )including, water supply, Sanitary installations, Drainage and Development ... KVA online UPS etc.. ...
Construction of 0.5 Units Boys Hostel , 0.50 Units girls hostel , residential Quarters 27 Nos (Principal residence - 1 No, type ll - 10 Nos, Type lll 15 Nos, 1 no Guest house ) including water supply , Sanitary installations , drainage and ... KVA online UPS etc. ...
Construction of 0.50 Units Boys Hostel, 0.50 Units Girls Hostel, Principal Quarter, 16 nos Type III, 10 nos Type II including water supply, sanitary installations, drainage and sports facilities and development works including providing IEI & Fans, ... KVA online UPS etc. ...
Construction of 0.5 Units Girls Hostel, Residential Quarters 27 Nos ( Principal Residence -1 No., Type II-10 Nos., Type III - 15 and 1No Guest House ) including water supply, Sanitary installations, Drainage and Development works including providing ... 5KVA online UPS ,etc ...
Replacement of ongrid solar inverter for 35kWp SPP at EPCC Gollapudi
Infrared thermal imaging system (Thermal imaging camera) as per SCR specification Lr.No.E.207/TRD/Genl.Corr. dated 14.12.2023, having touch screen, temperature range from - 20 degree celsius to 650 degree Celsius, with thermal sensitivity 80mk ... rechargeable battery bank , ...
Infrared thermal imaging system (Thermal imaging camera) as per SCR specification Lr.No.E.207/TRD/Genl.Corr. dated 14.12.2023, having touch screen, temperature range from - 20 degree celsius to 650 degree Celsius, with thermal sensitivity 80mk ... rechargeable battery bank , ...
Supply, Installation, Testing and Commissioning of 268 Nos. of 2 Ton, 5 star, Inverter type split Air Conditioning (AC) units along with 5kVA Stabilizers and 14 Nos. of 4 HP Industrial VRV type AC unit (1 No outdoor unit and 2 Nos. Indoor units)
MOEI & Fans, Mtce & operation of 160 KVA DG Set, Passenger lifts, sub-station, fire alarm system, wet riser system, UPS system, EPABX and AC Units for G.S.I at Marripalem, Visakhapatnam during 2022-23. SH: Providing Services for Operation and Maintenance of IEI & Fans, Substation, Fire Fighting with wet riser system and fire alarm system, and AMC for 160 KVA DG set and Split/Window AC Units. Subwork/Packages: One
MOEI & Fans, Mtce & Operation of 160 KVA DG set, passenger Lifts, Sub-station, fire alarm system, wet riser system, UPS system, EPABX and AC units for GSI at Marripalem, Visakhapatnam during 2023-24. SH: Providing Services for Operation and Maintenance of IEI & Fans, Substation, Fire Fighting with wet riser system and fire alarm system, and AMC for 160 KVA DG set and Split/Widnow AC Units. Subwork/Packages: One
Construction of New Office Building G plus 1 storeyed including internal water supply, sanitary installations, drainage, IEI and Fans, split AC system, fire fighting with down comer system, manual fire alarm system, UPS system, LAN networking system, CC tv system, EPABX system, UPS and development works like external water supply connection, UG sump, internal roads, borewells with pump sets, rain water harvesting etc for Directorate of Mines Safety at Nellore, AP
Inverter based 600 Amps,3 phase DC welding machine including power saver, welding cable(20 meters) with electrode holder, earthing clamp with earth lead(20 meters) fast plug to model no.Tornado 601 of M/s.Ador Fontech make or its equivalent. Detailed technical specification as per attached annexure.
Inverter based 600 Amps,3 phase DC welding machine including power saver, welding cable(20 meters) with electrode holder, earthing clamp with earth lead(20 meters) fast plug to model no.Tornado 601 of M/s.Ador Fontech make or its equivalent. Detailed technical specification as per attached annexure.
6 KVA UPS in Parallel configuration, Batteries, Battery Rack, MCB Enclosure box, 64 Amp MCB, 32 Amp MCB, Power cable, Laptop, RCMS Software, LAN Cable, Perforated PVC duct, Power Strip, Installation and Commissioning, Training
Custom Bid for Services - Maintenance Contract of Wipro RC, Hitachi RC items (Computers and its peripherals, Printers, UPS Systems, Laptops, Scanners etc) and other IT maintenance activities at BHEL-HPVP, Visakhapatnam Similar Category Support Services
Construction of Research Building for National Centre for Coastal Research (NCCR) at Dolphin Nose, Visakhapatnam including internal and external water supply, sanitary installations, drainage, IEI and Fans, Street lighting, Pump sets, Fire Fighting ... set, UPS system , ... Set, UPS system , ...
hand held search light Hand Held Search Light ( 15 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Type of lamp LED Halogen, Xenon, LED Battery capacity (AH) 2 - CONSTRUCTIONAL Dia of search light (mm) 50 to ... SMF, Lithium ion Battery Voltage ... (SMF Lead acid battery ) ... (SMF Lead acid battery ), ... (SMF Lead acid battery ), ... (SMF Lead acid battery ), ...
Construction of 0.5 Units Boys Hostel , 0.50 Units Girls Hostel, Residential Quarters 27 No.s ( Principal Residence - 1 No., Type II -10 Nos., Type III -15 plus 1No Guest House ) including , water supply, Sanitary installations , Drainage, and ... KVA online UPS , ...
Construction of Administrative Building for Punjab National Bank at Amaravati Andhra Pradesh including IWS, SI, drainage, IES and fans fire fighting System with Wet Riser, Automatic Fire Alarm System, DG Set, Sub-Station, Passeneger Lifts, UPS System, HVAC System, Roof Top Solar Power Generation System, STP, ELV Systems (LAN, CCTV and IP PBX), Building Management System (BMS), Mechanical Ventilation System, Street Lighting, Borewell Pump Sets, EV Charging System and Horticulture Works Etc.
Design, Supply, Installation, and commissioning of IGBT INVERTER BASED AIR PLASMA CUTTING MACHINES a
Air Conditioner Experience with Gov. Required 5 Year (s) Air Conditioner ( 10 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values CAPACITY/GENERIC Type of Air conditioner High wall ... AC Inverter (Variable ... Speed) Inverter (Variable ...
i S and F 3 Phase input 110V DC output 20A float cum boost charger with DCDB 4Nos ii S and F 110V 100AH Battery bank set of 55 batteries Each 2V 100AH VLRA batteries with rack mounting Make Exide
Construction of Academic block-2 including internal Water supply, Sanitary, Drainage and development works like UG sump, CC Roads, External sewerage, water supply lines, storm water drains etc. and providing IEI & Fans, Street lighting, Pump Sets, ... set, UPS System , ...
Integrated IR, HD Megapixel, IR IP PTZ Dome Camera, Layer 2 Managed Stackable Switch, 6 Core single mode armoured OFC cable, 3 Core armoured power cable, 25 mm casing capping, HDPE pipe for underground cabling, 25 mm PVC conduit pipe, Flexible Pipe, ... 2X10KVA online UPS for ... individual battery bank of ... of SMF batteries , ...
Construction of Laboratory for BSL3 Facility and for Model systems in Biology at IISER, Tirupati, Permanent Campus in EPC mode -I (Design and Build Basis) SH: (a) Building portion i/c Internal Water supply, Sanitary installations, External Service ... KVA Online UPS , ...
Construction of Administrative Building for Bank of Baroda at Amaravati, Andhra Pradesh including Internal water supply, sanitary installations, drainage, Internal Electrical Installations and Fans, Fire Fighting System with Wet Riser, Automatic Fire ... Lifts, UPS System , ...
Supply of 1.5 TR 5 star and 1.8/2.0 Ton split type inverter model A.C units to A.E-I in ESD-II,Tirupati for the work of AME for repairs and servicing of A.C units available in Central Hospital of A.E-I section in ESD-II,Tirupati for the year 2018-19 (Part - C).
REFRIGERATOR SINGLE DOOR 183 LTR capacity, Direct Cool, 5 Star Rated with operating Voltage 230V,50HZ, Rated Power Input:60W, Rated Current:1.0A, With Digital Inverter Compressor of 20 Years Minimum Warranty, with Eco- Friendly Refrigerant preferably R-600a, Confirm to IS:17550( Part1) of Make: SAMSUNG Model.No.RR20D2825CR/NL of Makes: SAMSUNG, Whirlpool, LG, ONLY
NEUTRAL POINT CLAMPED INVERTER BASED THREE PHASE INDUCTION MOTOR DRIVE SETUP, 5 PHASE 5 LEVEL CASCADED H BRIDGE INVERTER MODULE, 6 PHASE PMSM WITH DC MACHINE LOAD SETUP, DESIGN AND IMPLEMENTATION OF GATE DRIVER CIRCUIT FOR A MOSFET AND SCR AND GATE ... LEVEL INVERTER
Construction of 17 Court Building complex at Vizianagaram Andhra Pradesh including water supply sanitary installations drainage IEI Fans water coolers UPS System Fire Fighting with wet riser system Addressable Fire Alarm System 7 Nos 13 Passenger lift VRF VRV AC System CCTV System LAN networking system AV System UG Sump Internal roads Storm Water drains septic tank Steet lighting Pump Sets Substation DG set and EV Charger SH Providing Man power Services for carrying out works in sub division office CPWD at Vizianagaram
Average Turn Over of Last 3 Years 4 Lakh (s) Online UPS ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 5.0 KVA 5.0 KVA Technology IGBT-PWM with inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer, IGBT- PWM with inbuilt isolation transformer, IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave, 50Hz single phase 160V - 260V sinewave, 50Hz, Three phase 300 V - 450V sinewave, 50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz, 3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 60 60 1/4 Minimum VAH (VAH) 8193 400-640000 Warranty for UPS (Years) 2 1, 2, 3, 4, 5 Movable trolly for Batteries Without trollery but with rack With, Without, Without trollery but with rack Warranty for battery 2 1, 2 Degree of Protection IP21 IP21, IP20 Cabling 5 meters for input and out put With With, Without Paralleling kit for synchronising Without With, Without Installation and Commissioning Yes * CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 * Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I, II&III) * FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 * Voltage Regulation from no load to full load (%) /= 3% * 20% Overload limit for minimum 10 minutes Yes * Overall Efficiency (%) >/=90% * Total Harmonic Distortion(THD) (%) Maximum 3% * 50% Overload limit for minimum 1 minutes Yes * PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes * Protection of Over voltage, Short Circuit & over load at UPS output terminal Yes * METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage, Output AC Volt age, Current, Frequency, Battery Voltage and Current Yes * Indicators for mains Yes * 2/4 presence, Battery charging and discharging, Output Over Load, Low Battery Voltage REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C, two cycles of (12+12) hours each 2007) Yes * Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes * Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes * Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes * Type Test Certificate No. - * Type Test Certificate date - * Name of Lab - * Address of Lab - * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Namala Soma Sekhara Rao 515801, O/o Superintendent, RMS AG, Modinabad, Near Telephone Exchange, 1 15 3/4 Guntakal
Camera for CCTV System, Video Recorder For Cctv System-IS 9000, Layer 2 Access Switch, Liquid Crystal Display LCD Panel or Monitors, Add on GATEWAYS and Accessories for PABX System, Power Cable For Direct Burial Xlpe Ugac Cable-IS: 10418, Online Ups-IS:9000, Wireless Access Point
Supply, Installation, Testing, Configuration and Training of Software Defined - Wide Area Network (SD-WAN) devices along with necessary Hardware, Bandwidth Licenses, IPS and IDS security and 1 KVA UPS at the locations of APSPDCL in 9 circles with 5 Years warranty and support.
Construction of 17 Court Building complex at Vizianagaram, Andhra Pradesh including internal water supply ,sanitary installations, drainage, IEI & Fans ,Water Coolers, UPS System, Fire Fighting with wet riser system, Addressable Fire Alarm system,7 No s 13 passenger Lift, VRF/VRV AC system, LAN Networking system, IP Based PBX System, AV System, UG Sump, Internal roads, storm water drains, septic tank, street lighting, pump sets, substation, DG Set and EV Charger. SH: Providing manpower services for carrying out works in subdivision office, CPWD, at Vizianagaram.
AME for Temporary Illuminations, AMF Panels, APFC Panels, UPS system etc. in SV Temple at Kanyakumari in Tamilnadu State pertaining to AE-I section in ESD-III, Tirupati for the year 2026-27
Replacement of piano switches with new modular switches, switch boards, power outlets along with GI Box, Dbs , MCBs , fluorescent fittings with LED fittings, mercury/sodium vapour lamps with LED street lights and point wiring for call bell points, ... & inverter supply ...
Inverter (V2) (Q2) MSE Relaxation for Years of Experience and Turnover No Startup Relaxation for Years of Experience and Turnover No Minimum number of bids required to disable automatic bid extension 1, -- Number of days for which Bid would be auto -- extended 3 Number of Auto Extension count 1 Bid to RA enabled No Type of Bid Single Packet Bid Time allowed for Technical Clarifications during technical evaluation 2 Days Bid Number : GEM/2026/B/7152247 Dated : 27-01-2026 Bid Document 1/7 ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) Yes Inspection to be carried out by Buyers own empanelled agency Yes Type Of Inspection Pre Dispatch Name of the Empanelled Inspection Agency/Authority RITES Estimated Bid Value 1104972 Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Required No ePBG Detail Required No
MBSRE CENTRAL CONTROL UNIT, BOX LOUDSPEAKER 4W NWT, HORN LOUDSPEAKER 1 to 15W WT, VOLUME CONTROL UNIT, EXP HORN LOUDSPEAKER, ANNOUNCEMENT STATION, ANNOUNCEMENT STATION FLUSH, FLASHER, FLASHER EX TYPE, JUNCTION BOX, LOUD SPEAKER, UPS, BATTERIES, FOOT PUSH SWITCH, MAN OVERBOARD ALARM, INSTALLATION AND COMMISSIONING MATERIAL, ON BOARD SPARES, DRAWINGS AND DOCUMENTATION, INSPECTION CHARGES, TRAINING, SERVICE Engineer charges, EXTENDED WARRANTY
Construction of Single Court Building (Junior Division) at Srungavarapukota, Vizianagaram District, Andhra Pradesh inlcuding internal water supply, sanitary installations, drainage, IEI & Fans, Street lighting, Pump Sets, water coolers, LT Panels, DG ... set, UPS system , ...
SITC of 05 KVA UPS with Battery Bank 2Years warranty and 4 Years CAMC, Battery Banks with Battery stand and accessories, UPS Output Surge Protectors, Power cable 3 core, 6 sq.mm, Power Cable Single core, Black 6 sq.mm, Power Cable Single core, Red 6 sq.mm, PVC insulated 16 sq.mm Single core earthing cable, Earth strip size 25X6 sq.cm length 30cm, Battery Isolators for Equipment batteries, Circuit breaker 32A, 3 pole, Circuit breaker 16A, 2pole, 6A, 16A sockets Boxes, Each box -5 Sockets, Distribution boxes for placing 2 Nos of 32A 3P and 1 No of 16A 2P MCB, Distribution boxes for placing 8 No 16A 2P MCB, CAT 6 LAN cable of industrial standard, RJ 45 connectors, PVC CASING and CAPING 2 INCH, Installation and Integration Charges, Training, Manuals
Supply and Installation of Five Phase PMSM Motor Coupled DC Machine Setup (Q3), Supply and Installation of Five Phase Multi Level Inverter (Q3)
SUPPLY OF WINDOW A/C, 1.5 T, 5 STAR INVERTER FOR SEA WATER PUMP HOUSE STAGE-II SDSTPS FOR THE YEAR 2026-27
Construction of Girls Hostel (G plus 2) floors for 100 trainees or SRFMT and TI Tractor Nagar at Garladinne Anantapur Andhra Pradesh including internal and external water supply lines sanitary installations drainage internal and external Electrical ... system UPS system LAN ...
Structural Design and Construction of New Office Building (Basement plus G plus 4 including water supply, sanitary installations, Drainage, storm water drains, terrace water tanks, underground sump, levelling, internal roads and paths, compound wall, ... Set, UPS System , ...
Construction of Girls Hostel (G plus 2) floors for 100 trainees or SRFMT and TI Tractor Nagar at Garladinne Anantapur Andhra Pradesh including internal and external water supply lines sanitary installations drainage internal and external electrical ... system UPS system LAN ...
Providing Air Conditioning System (Inverter type Cassette AC Units) & Audio Video System to Kalam Hall at ACSR Govt. Medical College, Nellore in SPSR Nellore District
Supply, installation, and commissioning of Lobby TSS equipment set for CMS (KIOSK), with 02 years onsite comprehensive Warranty and certificate with complete fitment of accessories in numbers of sets as per CRIS specification No. ... 1 KVA UPS with ...
1) Structural Design and Construction of New Office Building (Basement G 4) for Mercantile Marine Department (MMD) at Harbour Road, Visakhapatnam. 2) Design and Construction of New office building for MSME, Visakhapatnam. SH: Building Portion ... KVA Online UPS , ...