Loading…
Loading…
3,396 results • Best match
godrej Cooling Only 1 Ton 3 Star (ISEER value from 3.8 to 4.39) Inverter, godrej Cooling Only 1 Ton 3 Star (ISEER value from 3.8 to 4.39) Inverter AC - Variable Speed Wall Mount Split AC
LG Cooling Only 1.5 Ton 3 Star (ISEER value from 3.8 to 4.39) Inverter, LG Cooling Only 1.5 Ton 3 Star (ISEER value from 3.8 to 4.39) Inverter AC - Variable Speed Wall Mount Split AC
godrej Cooling Only 1 Ton 3 Star (ISEER value from 3.8 to 4.39) Inverter, godrej Cooling Only 1 Ton 3 Star (ISEER value from 3.8 to 4.39) Inverter AC - Variable Speed Wall Mount Split AC
intec Cooling Only 2 Ton 2 Star (ISEER value from 3.5 to 3.79) Inverter, intec Cooling Only 2 Ton 2 Star (ISEER value from 3.5 to 3.79) Inverter AC - Variable Speed Wall Mount Split AC
godrej Cooling Only 2 Ton 3 Star (ISEER value from 3.8 to 4.39) Inverter, godrej Cooling Only 2 Ton 3 Star (ISEER value from 3.8 to 4.39) Inverter AC - Variable Speed Wall Mount Split AC
godrej Cooling Only 2 Ton 3 Star (ISEER value from 3.8 to 4.39) Inverter, godrej Cooling Only 2 Ton 3 Star (ISEER value from 3.8 to 4.39) Inverter AC - Variable Speed Wall Mount Split AC
LG Cooling Only 1.5 Ton 3 Star (ISEER value from 3.8 to 4.39) Inverter, LG Cooling Only 1.5 Ton 3 Star (ISEER value from 3.8 to 4.39) Inverter AC - Variable Speed Wall Mount Split AC
intec Cooling Only 2 Ton 3 Star (ISEER value from 3.8 to 4.39) Inverter, intec Cooling Only 2 Ton 3 Star (ISEER value from 3.8 to 4.39) Inverter AC - Variable Speed Wall Mount Split AC
godrej Cooling Only 1 Ton 3 Star (ISEER value from 3.8 to 4.39) Inverter, godrej Cooling Only 1 Ton 3 Star (ISEER value from 3.8 to 4.39) Inverter AC - Variable Speed Wall Mount Split AC
LG Cooling Only 1.5 Ton 3 Star (ISEER value from 3.8 to 4.39) Inverter, LG Cooling Only 1.5 Ton 3 Star (ISEER value from 3.8 to 4.39) Inverter AC - Variable Speed Wall Mount Split AC
intec Cooling Only 1.5 Ton 3 Star (ISEER value from 3.8 to 4.39) Inverter, intec Cooling Only 1.5 Ton 3 Star (ISEER value from 3.8 to 4.39) Inverter AC - Variable Speed Wall Mount Split AC
intec Cooling Only 1.5 Ton 3 Star (ISEER value from 3.8 to 4.39) Inverter, intec Cooling Only 1.5 Ton 3 Star (ISEER value from 3.8 to 4.39) Inverter AC - Variable Speed Wall Mount Split AC
godrej Cooling Only 2 Ton 3 Star (ISEER value from 3.8 to 4.39) Inverter, godrej Cooling Only 2 Ton 3 Star (ISEER value from 3.8 to 4.39) Inverter AC - Variable Speed Wall Mount Split AC
godrej Cooling Only 2 Ton 3 Star (ISEER value from 3.8 to 4.39) Inverter, godrej Cooling Only 2 Ton 3 Star (ISEER value from 3.8 to 4.39) Inverter AC - Variable Speed Wall Mount Split AC
LG Cooling Only 1.5 Ton 3 Star (ISEER value from 3.8 to 4.39) Inverter, LG Cooling Only 1.5 Ton 3 Star (ISEER value from 3.8 to 4.39) Inverter AC - Variable Speed Wall Mount Split AC
Optical Fiber Cable 12 Core, Media Converter 4 x Ethernet Port ., Power Adopter for PTZ Camera 24 V Output ., Power Adopter for PTZ Camera 12 V Output ., OFC Joint Closure, Online UPS 3 KVA, UPS 2 KVA, Patch Cord 10 mtr length
lead acid battery Lead Acid Battery ( 6 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Types of Lead Acid of Battery Lead-Acid Storage Batteries for Motor Vehicles with Light weight and High Cranking Performance conforming to IS:14257/1995 Lead-Acid Storage Batteries for Motor Vehicles with Light weight and High Cranking Performance conforming to IS:14257/1995 Nominal Voltage of Battery (volts) 12.0 Volt 12.0 Volt Material of container Polypropylene Polypropylene Rated Capacity at C20 discharge (AH) 180 180 Warranty (Years) 3 Years 3 Years, 4 Years, 2 Years Battery Condition Charged * CONSTRUCTIONAL Dimensions (L x W x H) (mm x mm x mm) As per relevant IS Specifications * Volume of Electrolyte (ml) 15900 * Weight of Dry Battery Yes. * 1/3 (Kg) shall be as per relevant IS: Specn., corresponding Ah No.of cells per Battery (No.) 6 Cells for 12 Volt battery * CERTIFICATIONS Availability of Test Reports from Central Govt./NABL/ILAC accrediated Lab showing conformity to the specifications Yes * Address of the Lab KOLKATA * Name of the Lab EXIDE INDUSTRIES LTD * Test Report No. T 0256398 * Test Report Date 21/05/2017 * Compulsory Registration (CRS) of BIS for safety as per IS 16046 as applicable. Secondary Cells and (Batteries containing Alkaline or other non- acid Electrolytes-Safety Requirements for Portable sealed secondary cells, and for Batteries made from them for use in portable applications YES * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Rajendra Kumar Sahu 382045, DIG HQ, SECTOR HEADQUARTER BSF GANDHINAGAR, CHILODA ROAD, GANDHINAGAR, GUJARAT PIN 382045 6 15
Supply and installation of 8TR Inverter Type Packaged Air Conditioner as per attached specs (Q3)
DESIGN SUPPLY INSTALLATION TESTING&COMMISSIONING OF OFF-GRID SOLAR POWER PLANT WITH HYBRID INVERTER (Q3)
Annual Maintenance Service - Desktops, Laptops and Peripherals - UPS (Online 10 KVA); Vertiv Online UPS, Laptops and Peripherals - UPS (Online 6 KVA); Vertiv Online UPS
Server (Q2), Online UPS (V2) (Q2), Desktop Computers (Q2)
Workstation ( PAC Only ), Online Ups-IS:9000 ( PAC Only )
IFB Cooling Only 1 Ton 3 Star (ISEER value from 3.8 to 4.39) Inverter AC, IFB Cooling Only 1 Ton 3 Star (ISEER value from 3.8 to 4.39) Inverter AC - Variable Speed Wall Mount Split AC
01 No sine wave 24 V inverter UPS of 2KVA, with 24 months warranty and 02 Nos Tubular inverter battery model no. Inva Gold IGST1500 12V 150 AH with 36 months warranty with installation Make:- Exid
Supply of BATTERY OPERATED SS 304 AUTOMATIC SOAP/SANITIZER DISPENSOR 1100ML HAVING DOLPHY MODEL NO. DSDR0112-S OR EQUIVALENT suitable for VANDE BHARAT Accepted Make/Brand:DOLPHY
Vocational Training Services - Version 2 - offline; 4; Service providers location; Inverter Installation Training With Equipment Kit
VFD Inverter [ Especially for EOT Cranes various motions .Specification as per annexure A ACCEPTED MAKE--ANGEL
Please refer tender documents
Please refer tender documents
Desktop Computers (Q2), Computer Printers (Q2), Online UPS (V2) (Q2)
Comprehensive annual maintenance contract CAMC of Riello make 2 x 160 KVA PICF building and 2 x 30 KVA LTVC building UPS system for two year at Bopal, Ahmedabad
Lead Acid Storage Batteries for Motor Vehicles as per IS 7372 (Q3), Lead Acid Batteries for Motor Vehicles with Light Weight and High Cranking Performance as per IS 14257:2019 (Q3)
Lead Acid Storage Batteries for Motor Vehicles as per IS 7372 (Q3), Lead Acid Batteries for Motor Vehicles with Light Weight and High Cranking Performance as per IS 14257:2019 (Q3)
Lead Acid Storage Batteries for Motor Vehicles as per IS:7372 (Q3), Buy Back Battery 12 V, 220 AH (Q3), Stationary Value Regulated Lead Acid Batteries as per IS:15549 (Q3)
Entry and Mid Level Desktop Computer (Q2), Online UPS (V2) (Q2)
Desktop Computers (Q2), Online UPS (V2) (Q2), Multifunction Machines MFM (Q2)
Supply, Installation, Testing and Commissioning of UPS Battery (Q3)
SITC OF CENTRALIZED 250KVA, 3-PHASE MODULAR UPS SYSTEM WITH 210 AH BATTERY BANK & ASSOCIATED ACCESSO, CAMC 3RD YEAR -AFTER COMPLETION OF WARRANTEE PERIOD, CAMC 4TH YEAR -AFTER COMPLETION OF WARRANTEE PERIOD, CAMC 5TH YEAR -AFTER COMPLETION OF WARRANTEE PERIOD
Repairing 03 Nos of 5 decimal 5 MVA Inverter Duty Transformer IR07 Sl No PTD 1121 10 IR 14 Sl No PTD 1121 09 and IR 20 Sl No PTD 1121 16 of 100 MW GSECL Raghanesda I
Lead Acid Storage Batteries for Motor Vehicles as per IS 7372 (Q3), Lead Acid Batteries for Motor Vehicles with Light Weight and High Cranking Performance as per IS 14257:2019 (Q3) (3 (3 ))
PROVN OF COMPACT INVERTER ROOM, CONTROL ROOM AND SECURITY CABIN FOR SOLAR POWER PLANT AT AF STATION SAMANA
(1) MOEI and Fans i/c RMO compound light and pump set of Special Bureau colony, University Road, Rajkot. SH: Providing Services of 01 no. Wireman cum operator and 01 no Khalasi. (2) MOEI and Fans i/c RMO compound light and pump set of Special Bureau ... 100 KVA UPS system at ...
Product Maintenance Service for 2 TON INVERTER AC (Hitachi) (RMB524HBEA), Product Maintenance Service for SPLIT AC VOLTAS 1.5TON, Product Maintenance Service for 1.5 Ton 3 Star Kaze Plus RAW518KUDZ1 Hitachi Window Air conditioner
Battery Secondary Lead Acid MT Type (Defence) (Q2), Lead Acid starter Batteries (Q3), Lead Acid Batteries for Motor Vehicles with Light Weight and High Cranking Performance as per IS 14257:2019 (Q3) (3 (3 ))
Online UPS Online UPS ( 2 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 5.0 KVA 5.0kva Technology IGBT-PWM with inbuilt isolation transformer igbt-pwmwithinbuiltisol ationtransformer Input Power single phase 160V - 260V sinewave, 50Hz singlephase160v-260vs inewave50hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz, 3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 60 60 Minimum VAH (VAH) 8000 Warranty for UPS (Years) 2 1, 2, 3, 4, 5 Movable trolly for Batteries Without trollery but with rack With, Without, Without trollery but with rack Warranty for battery 2 2 Degree of Protection IP20 ip20 Cabling 5 meters for input and out put Without With, Without Paralleling kit for Without With, Without 1/5 synchronising Installation and Commissioning Yes N/A CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.0 N/A Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I, II&III) N/A FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 N/A Voltage Regulation from no load to full load (%) /= 3% N/A 20% Overload limit for minimum 10 minutes Yes N/A Overall Efficiency (%) >/=90% N/A Total Harmonic Distortion(THD) (%) Maximum 3% N/A 50% Overload limit for minimum 1 minutes Yes N/A PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes N/A Protection of Over voltage, Short Circuit & over load at UPS output terminal Yes N/A METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage, Output AC Volt age, Current, Frequency, Battery Voltage and Current Yes N/A Indicators for mains presence, Battery charging and discharging, Output Over Load, Low Battery Voltage Yes N/A REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C, two cycles of (12+12) hours each 2007) Yes N/A 2/5 Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes N/A Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes N/A Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes N/A Type Test Certificate No. NTH(SR)NMIS/2016/006 C N/A Type Test Certificate date 07/11/16 N/A Name of Lab NTH N/A Address of Lab CHENNAI N/A As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes N/A * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Arun Aeri 382721, Air Force Station Vadsar, 2 15 EMD Required No ePBG Required No
Sir, Pl. approve. OK
SUPPLY INSTALLATION, TESTING & COMMISSIONING OF BATTERY BANK FOR WAGHODIA UPS WITH BUY BACK UNDERA., INSTALLATION TESTING AND CONFIGURATION COMMISSIONING OF BATTERY BANK FOR WAGHODIA UPS WITH BUY BACK
Desktop PC, Mobile jammer, Bio Metric System, Podium Control, Online UPS 1 KVA
Line Interactive UPS with AVR (Version 2.0) (Q2), Online UPS (Version 2.0) (Q2)
High End Desktop Computer (Q2), Online UPS (V2) (Q2), Computer Printer (V2) (Q2)