Custom Bid for Services - Installation commissioning of Solar inverter, Custom Bid for Services - Supply Fabriation installation of GI Structure, Custom Bid for Services - Supply installation of Cable DCDB ACDB DC Cable including earthing Lighting arrestor, Custom Bid for Services - Installation commissioning
Customized AMC/CMC for Pre-owned Products - Comprehensive Annual Maintenance Services; Synergy make; Comprehensive Maintenance Contract (CMC); Hiring of Comprehensive Annual Maintenance Services for o Synergy make UPS system for Bhubaneswar and Cutta..
High Configuration Rack Server, Desktop PC, Monochrome Printer, Online UPS, Scanner, Click Scanner
Server (Q2), Entry and Mid Level Desktop Computer (Q2), Online UPS (V2) (Q2)
Supply, Installation and commissioning of Online UPS with Inbuilt Isolation transformer suitable for single phase AC input and Single phase AC output,Floor mounted type.rating of UPS 5.0 KVA,indicative back up time :120 minutes including all accessories and input,output power cables with 03 years warranty including battery.
UPS, SYSTEM, 3KVA, 1PHASE (Q3)
UPS, SYSTEM, 3KVA, 1PHASE (Q3)
UPS, SYSTEM, 3KVA, 1PHASE (Q3)
Online UPS (V2) (Q2) MSE Exemption for Years Of Experience and Turnover Yes Startup Exemption for Years Of Experience and Turnover Yes Document required from seller OEM Authorization Certificate, Additional Doc 1 (Requested in ATC) *In case any ... category Online UPS (V2) ...
Inverter with sine wave output ( PAC Only ) Bidder Turnover (Last 3 Years) 1 Lakh (s) Experience Criteria 1 Year (s)
SUPPLY OF INVERTER FOR FUEL PUMP MOTOR EQUIVALENT TO EMD / PARAGON, TO EMD PART NO:40122943. MAKE-Greentech Labs LLP,
Standby Inverter Electronic card along with Installation Kit suitable to AC-3 Phase fuel pump motor to EMD Part.No: 40122943
1) RALLIWOLF Corded Small Angle Grinders, Power 220-240V AC, 50/60 Hz Brand: RALLIWOLF or similar. 2) Portable Electric Cut off Saw, specification as per Annexure-I attached, Make: Bosch or IBELL or INGCO or Dewalt or Equivalent. 3) Thermal ... built-in Lithium -ion ... Lithium- ion Battery Operating ...
Laptop i3 Required with Windows 10 Home and MSO, Laptop i5 Required with Windows 10 Professional and MSO, Laptop i7 Required with Windows 10 Professional and MSO, desktop required as per buyer, HP 1020 Printer Required, Projector with Screen & Smart ... KVA Online ups & ... & Batteries as ... Requirement, Inverter Batteries ...
Server, All in One PC, Online UPS 10 KVA, OFC Cable, UTP Cable, Installation
Video Conferencing End Point (Q2), Online UPS (V2) (Q2), High End Desktop Computer (Q2)
DESKTOP COMPUTER ( 7 box ), 10 KVA ONLINE UPS ( 1 box ), QUICKHEAL ANTIVIRUS ( 3 box )
interactive panels and accessories, Online Ups-IS:9000, USB Camera for Video Conferencing System
Online UPS Experience with Gov. Required 1 Year (s) Online UPS ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 3.0 KVA 3.0 KVA Technology MOSFET-PWM with inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer, IGBT- PWM with inbuilt isolation transformer, IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave, 50Hz single phase 160V - 260V sinewave, 50Hz, Three phase 300 V - 450V sinewave, 50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz, 3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 15 15, 30, 60, 90, 120, 180, 240 Minimum VAH (VAH) 21600 Warranty for UPS (Years) 1 1, 2, 3, 4, 5 1/4 Movable trolly for Batteries Without With, Without, Without trollery but with rack Warranty for battery 1 1, 2 Degree of Protection IP21 IP21, IP20 Cabling 5 meters for input and out put Without With, Without Paralleling kit for synchronising Without With, Without Installation and Commissioning Yes - CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.0 - Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I, II&III) - FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 - Voltage Regulation from no load to full load (%) /= 3% - 20% Overload limit for minimum 10 minutes Yes - Overall Efficiency (%) >/=90% - Total Harmonic Distortion(THD) (%) Maximum 3% - 50% Overload limit for minimum 1 minutes Yes - PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes - Protection of Over voltage, Short Circuit & over load at UPS output terminal Yes - METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage, Output AC Volt age, Current, Frequency, Battery Voltage and Current Yes - Indicators for mains presence, Battery charging and discharging, Output Over Load, Low Battery Yes - 2/4 Voltage REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C, two cycles of (12+12) hours each 2007) Yes - Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes - Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes - Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes - Type Test Certificate No. TC245-7895 - Type Test Certificate date 21st May, 2016 - Name of Lab APC Bangalore - Address of Lab APC Bangalore - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Not applicable presently - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sanjaya Kumar Patro 752050, National Institute of Science Education and Research NISER Campus Post Office Jatani 1 15
Material Code -26304001100 -Kinet5700 Inverter Cat 2198 D020 ERS3, Material Code - 86505502160 - Servo Motor Cat No MPL B540D MJ74AA, Material Code - 26304001090 - Kinet5700 Power supply Cat 2198 P031, Material Code - 00000000001 - DUMMY - PLEASE DO NOT QUOTE THIS ITEM, Material Code -00000000002 - DUMMY - PLEASE DO NOT QUOTE THIS ITEM
Inverter (V2) (Q2) MSE Relaxation for Years of Experience and Turnover No Startup Relaxation for Years of Experience and Turnover No
STANDBY INVERTER ELECTRONIC CARD ALONG WITH INSTALLATION KIT SUITABLE TO AC- 3 PHASE FUEL PUMP MOTOR TO EMD PART NO 40122943
Inverter (V2) (Q2) MSE Relaxation for Years of Experience and Turnover No Startup Relaxation for Years of Experience and Turnover No
Supply and Installation of Cassette Air Conditioners (Inverter type) at New Board Room of Administrative Building.Make- Blue Star/ Carrier /Hitachi/Mitsubishi.
Custom Bid for Services - NONCOMPREHENSIVE BMC FOR 2X2 KVA 2X3 KVA 2 X 10 KVA 2 X 15 KVA HIREL MAKE UPS SYSTEM OF CPPII NSPCL ROURKELA Similar Category Customized AMC/CMC for Pre-owned Products
Layer 2 Access Switch (V2) (Q2), Online UPS (V2) (Q2), Professional Large Format Display (Q2)
Provision of UPS system for emergency lights and SITC of Water Coolers cum Purifiers system for ATC Tower Technical Block Fire Station EM Workshop ESS Hangar CCR for new ATC Tower cum Technical Block New Fire Station
SITC of 48V, 800AH LFP battery bank with racks and accessories at PHBMPL SV06
Inverter control PCB for CEA series Matrix 400 AC/DC Machine Part No: 376948 Make: CEA, Primary IGBT Transistor for CEA series Matrix 400 AC/DC Machine Part No: 286030 Make: CEA
Microscope Camera (Q3), Microscope Light Source (Q3), Computer Printer (Q3), Graphics Tablet (Q3), Online UPS (Q3)
Entry and Mid Level Desktop Computer (Q2), Multifunction Machine MFM (V2) (Q2), Online UPS (V2) (Q2)
PY9755484043, PY9755484051.1, PY9755484051.2, PY9755484027, PY9855484035
Custom Bid for Services - Supply Installation and Commissioning of 10 KVA UPS without battery of 2 nos as per Technical Specification, Custom Bid for Services - Supply Installation and Commissioning of 10 KVA UPS with battery of 2 nos as per Technical Specification, Custom Bid for Services - Supply Installation and Commissioning of Automatic Transfer Switch and its accessories of 1 number as per Technical Specification, Custom Bid for Services - Supply Installation and Commissioning of Network Rack with its fitting accessories for Automatic Transfer Switch of 1 nos as per Technical Specification, Custom Bid for Services - Supply of Junction Box A of 12 nos as per Technical Specification, Custom Bid for Services - Supply of Junction Box B of 20 nos as per Technical Specification, Custom Bid for Services - Supply of Junction Box C of 20 nos as per Technical Specification, Custom Bid for Services - Installation and Commissioning of Junction Boxes A B and C Type of 52 nos as per Detailed Erection and Commissioning Specification, Custom Bid for Services - Supply of Cable of 1000 meter as per Technical Specification, Custom Bid for Services - Laying Dressing Termination and Commissioning of Cable sizes of 2000 meter as per Detailed Erection Commissioning Specification, Custom Bid for Services - Supply of FRP Cable Tray of 300 mm width with fitting accessories of 300 meter as per Technical Specification, Custom Bid for Services - Supply of FRP Cable Tray of 200 mm width with fitting accessories of 300 meter as per Technical Specification, Custom Bid for Services - Laying Fixing and Commissioning of FRP Cable Trays of Size 300 mm and 200 mm width of 600 meter as per detailed Erection and Commissioning Specification, Custom Bid for Services - Supply of FRP LADDER TYPE 90 degree HORIZONTAL BEND 300 mm 10 Nos and HORIZONTAL BEND 200 mm 10 Nos with fitting accessories of 20 nos as per Technical Specification, Custom Bid for Services - Supply of FRP LADDER TYPE 90 degree VERTICAL INSIDE BEND 300
Inverter (V2) (Q2), Entry and Mid Level Desktop Computer (Q2), Portable Water Purifiers or Filters (Q3) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No Document required from seller ... category Inverter (V2) ...
SUPPLYING, FITTING AND FIXING OF 1.0T A.C. AND 1.5T A.C. INVERTER AND ACCESSORIES FOR OFFICE OF THE SUPERINTENDING ENGINEER, SORO CANAL DIVISION, SORO.
KALORIE Inverter 5.5 KVA Brand: KALORIE (Detailed Description/Specification as per Product # 1 of GeM Contract No. GEMC-511687738819590 dt.13/07/2026)
microtek Inverter 1.5 KVA Brand: microtek (Detailed Description/Specification as per Product # 1 of GeM Contract No. GEMC-511687749602758 dt.13/04/2026)
microtek Inverter 2 KVA Brand: microtek (Detailed Description/Specification as per Product # 1 of GeM Contract No. GEMC-511687780248347 dt.13/04/2026)
microtek Inverter 1.5 KVA Brand: microtek (Detailed Description/Specification as per Product # 1 of GeM Contract No. GEMC-511687703562712 dt.10/04/2026)
microtek Inverter 2.5 KVA Brand: microtek (Detailed Description/Specification as per Product # 1 of GeM Contract No. GEMC-511687714129642 dt.13/04/2026)
microtek Inverter 2 KVA Brand: microtek (Detailed Description/Specification as per Product # 1 of GeM Contract No. GEMC-511687788963390 dt.03/06/2026)
Inverter (V2) (Q2) ( PAC Only ) MSE Relaxation for Years of Experience and Turnover No Startup Relaxation for Years of Experience and Turnover No
Online UPS ( PAC Only ) Online UPS ( 1 ) ( Under PAC ) Make numeric Model numeric10kva31hpmaxfmi60min Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 10.0 KVA 10.0 KVA Technology IGBT-PWM with inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer, IGBT- PWM with inbuilt isolation transformer, IGBT-PWM without inbuilt isolation transformer Input Power Three phase 300 V - 450V sinewave, 50Hz Three phase 300 V - 450V sinewave, 50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz Backup time (Minutes) 60 60 Minimum VAH (VAH) 18720 18720 1/4 Warranty for UPS (Years) 3 3 Movable trolly for Batteries Without trollery but with rack With, Without, Without trollery but with rack Warranty for battery 2 2 Degree of Protection IP20 IP21, IP20 Cabling 5 meters for input and out put Without With, Without Paralleling kit for synchronising Without With, Without Installation and Commissioning Yes * CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 * Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I, II&III) * FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 * Voltage Regulation from no load to full load (%) /= 3% * 20% Overload limit for minimum 10 minutes Yes * Overall Efficiency (%) >/=90% * Total Harmonic Distortion(THD) (%) Maximum 3% * 50% Overload limit for minimum 1 minutes Yes * PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes * Protection of Over voltage, Short Circuit & over load at UPS output terminal Yes * METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage, Output AC Volt age, Current, Frequency, Battery Voltage and Current Yes * Indicators for mains presence, Battery charging and Yes * 2/4 discharging, Output Over Load, Low Battery Voltage REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C, two cycles of (12+12) hours each 2007) Yes * Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes * Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes * Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes * Type Test Certificate No. - * Type Test Certificate date - * Name of Lab - * Address of Lab - * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sukanta Kumar Mohanty 751001, OFFICE OF THE PRINCIPAL ACCOUNTANT GENERAL(A&E), ODISHA, BHUBANESWAR 1 15 3/4
LAPTOP PCs, DESKTOP PCs, MFD Printer, Photo Copier Machine, Microsoft Office, 1 KVA UPS
Online UPS ( PAC Only ) Online UPS ( 1 ) ( Under PAC ) Make apc Model apcmakesrc5kuxiwithoutbattery Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 5.0 KVA 5.0 KVA Technology IGBT-PWM without inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer, IGBT- PWM with inbuilt isolation transformer, IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave, 50Hz single phase 160V - 260V sinewave, 50Hz, Three phase 300 V - 450V sinewave, 50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz, 3 Phase 400V +/-1% with alternative user setable setting of 380V 1/4 +/-1% 50 Hz Backup time (Minutes) 15 15 Minimum VAH (VAH) 2000 400-640000 Warranty for UPS (Years) 2 1, 2, 3, 4, 5 Movable trolly for Batteries Without With, Without, Without trollery but with rack Warranty for battery 2 1, 2 Degree of Protection IP21 IP21, IP20 Cabling 5 meters for input and out put Without With, Without Paralleling kit for synchronising Without With, Without Installation and Commissioning Yes * CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 * Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I, II&III) * FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 * Voltage Regulation from no load to full load (%) /= 3% * 20% Overload limit for minimum 10 minutes Yes * Overall Efficiency (%) >/=90% * Total Harmonic Distortion(THD) (%) Maximum 3% * 50% Overload limit for minimum 1 minutes Yes * PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes * Protection of Over voltage, Short Circuit & over load at UPS output terminal Yes * METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage, Output AC Volt age, Current, Frequency, Yes * 2/4 Battery Voltage and Current Indicators for mains presence, Battery charging and discharging, Output Over Load, Low Battery Voltage Yes * REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C, two cycles of (12+12) hours each 2007) Yes * Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes * Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes * Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes * Type Test Certificate No. - * Type Test Certificate date - * Name of Lab - * Address of Lab - * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 3/4 1 Sanjaya Kumar Patro 752050, National Institute of Science Education and Research NISER Campus Post Office Jatani 1 15
Supply, Retro-fitment and commissioning of CAB MOUNTED COMPACT HVAC UNIT WITH BUILT IN INVERTER (1.75 TR cooling capacity) for HHP diesel electric locomotive.
Supply, Retro-fitment and commissioning of CAB MOUNTED COMPACT HVAC UNIT WITH BUILT IN INVERTER (1.75 TR cooling capacity) for HHP diesel electric locomotive.
Refer tender specifications and BoQ for details.
Online UPS ( PAC Only ) Online UPS ( 1 ) ( Under PAC ) Make rspower Model 5000-ol-2 Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 5.0 KVA 5.0 KVA Technology IGBT-PWM with inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer, IGBT- PWM with inbuilt isolation transformer, IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave, 50Hz single phase 160V - 260V sinewave, 50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz, 3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz 1/4 Backup time (Minutes) 60 60 Minimum VAH (VAH) 8000 400-640000 Warranty for UPS (Years) 2 1, 2, 3, 4, 5 Movable trolly for Batteries Without trollery but with rack With, Without, Without trollery but with rack Warranty for battery 2 1, 2 Degree of Protection IP21 IP21, IP20 Cabling 5 meters for input and out put With With, Without Paralleling kit for synchronising Without With, Without Installation and Commissioning Yes * CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 * Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I, II&III) * FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 * Voltage Regulation from no load to full load (%) /= 3% * 20% Overload limit for minimum 10 minutes Yes * Overall Efficiency (%) >/=90% * Total Harmonic Distortion(THD) (%) Maximum 3% * 50% Overload limit for minimum 1 minutes Yes * PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes * Protection of Over voltage, Short Circuit & over load at UPS output terminal Yes * METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage, Output AC Volt age, Current, Frequency, Battery Voltage and Yes * 2/4 Current Indicators for mains presence, Battery charging and discharging, Output Over Load, Low Battery Voltage Yes * REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C, two cycles of (12+12) hours each 2007) Yes * Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes * Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes * Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes * Type Test Certificate No. - * Type Test Certificate date - * Name of Lab - * Address of Lab - * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 3/4 1 AKSHAYA KUMAR REDDY N 751024, Central Tool Room & Training Centre, B-36 CNI Complex, Patia, Near Infocity, Bhubaneswar. 1 15
Repair, Maintenance, and Installation of Plant Systems/Equipments (Version 2) - Industry Unit; Battery Bank; Service Provider