Loading…
Loading…
3,897 results • Best match
PEAKMOUNT--PEAKMOUNT STAR PRIVATE LIMITED Potable water purification system with inbuilt water cooler. RO +UV Brand: PEAKMOUNT--PEAKMOUNT STAR PRIVATE LIMITED (Detailed Description/Specification as pe
PEAKMOUNT--PEAKMOUNT STAR PRIVATE LIMITED Potable water purification system with inbuilt water cooler. RO +UV Brand: PEAKMOUNT--PEAKMOUNT STAR PRIVATE LIMITED (Detailed Description/Specification as pe
Servicing and replacement of spare parts of Air Conditioning system, water cooler installed at Satyakam Bhawan , Arts faculty , Commerce Department , DSE etc at University of Delhi
Custom Bid for Services - 800062715 Maintenance contract for AC Water cooler Fridge RO at BTPS Eco Park Similar Category Operation and Maintenance Power House/Power Plant
ANNUAL MAINTENANCE SERVICES FOR WATER PURIFICATION AND CONDITIONING SYSTEM (Version 2) - RO Water Plant For Hemodialysis; upto 3; PACKAGE-5 : Water purifier and conditioning system maintenance involving basic servicing, filters, membranes, All electr..
ANNUAL MAINTENANCE SERVICES FOR WATER PURIFICATION AND CONDITIONING SYSTEM (Version 2) - WATER PURIFICATION SYSTEM UV BASED; upto 3; PACKAGE- 4 : Water purifier and conditioning system maintenance involving basic servicing, filters, membranes, All ele..
ANNUAL MAINTENANCE SERVICES FOR WATER PURIFICATION AND CONDITIONING SYSTEM (Version 2) - RO Water Plant For Hemodialysis; upto 3; PACKAGE-5 : Water purifier and conditioning system maintenance involving basic servicing, filters, membranes, All electr..
ANNUAL MAINTENANCE SERVICES FOR WATER PURIFICATION AND CONDITIONING SYSTEM (Version 2) - RO Water Plant For Hemodialysis; upto 3; PACKAGE-4 : Water purifier and conditioning system maintenance involving basic servicing, filters, membranes, All electr..
ANNUAL MAINTENANCE SERVICES FOR WATER PURIFICATION AND CONDITIONING SYSTEM (Version 2) - RO Water Plant For Hemodialysis; upto 3; PACKAGE-5 : Water purifier and conditioning system maintenance involving basic servicing, filters, membranes, All electr..
REPAIR REPLACEMENT OF DEFECTIVE PARTS OF HULL PAINTING PLANT DEGREASING PLANT AND EFFLUENT TREATMENT PLANT LOCATED AT VARIOUS LOCATIONS AND REPAIR MAINT OF RO WATER PURIFIERS INSTALLED AT VARIOUS UNITS AT DELHI CANTT UNDER GE U P and M DELHI CANTT
ANNUAL MAINTENANCE SERVICES FOR WATER PURIFICATION AND CONDITIONING SYSTEM (Version 2) - WATER FILTERS; 5 to 7; PACKAGE-2 : Water purifier and conditioning system maintenance involving basic servicing with maintenance of filters
MOEI and Fans and other electrical accessories of HMPs Flats/Bungalows/Duplex Flats under North Avenue, SD-4, DED-201, New Delhi. (SH : Comprehensive maintenance of existing R.O. water purifier system)
MOEI & Fans and other electrical accessories of HMPs Bungalows under North Avenue, DED-201, New Delhi. (SH : Comprehensive maintenance of existing R.O. water purifier system including replacement of spare parts etc.)
MOEI & Fans and other electrical accessories of HMPs Bungalows under South Avenue, DED-201, New Delhi. (SH : Comprehensive maintenance of existing R.O. water purifier system including replacement of spare parts etc.)
Provision and installation (wall hung) of reverse osmosis type water purifier suitable for purification of water having high TDS and salty/brakish taste compatible for input water with low pressure be
RMO of IEI, Fire extinguisher, CCTV System, Intercom/EPBAX system, Invertor Battery Set, Compound Light, servicing of water cooler, RO System, desert cooler, fans etc. at office building Subhash Nagar.
Potable water purification system Potable Water Purification System ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values EQUIPMENT TYPE & FEATURES Type Electrically Operated Reverse ... based water purifier Electrically ... based water purifier , ... operated water purifier , ... purifier, Water Purifier electro- ... of RO system Conforming ...
Supplying, Installation, Testing and Commissioning of water dispenser, refrigerator, wall fan, HDMI cable, VGA cable, cordless mic and other electrical works in Auditorium, old lecture theater New LT at MAMC, New Delhi.
SURE N PURE Floor Mounted Hot, Cold and Normal Water Dispenser Brand: SURE N PURE (Detailed Description/Specification as per Product # 1 of GeM Contract No. GEMC-511687767102401 dt.07/08/2023)
Running, Maintenance and Operation of 11/0.415 KV Sub-Station equipments ,DG set ,Internal, External and high mast lighting, submersible pump, refiiling of fire extinguisher and AMC Air Conditioning ,water cooler and RO units at MDCSC ,DDA.
Running, Maintenance and Operation of 11/0.415 KV Sub-Station equipments ,DG set ,Internal, External and high mast lighting, submersible pump, refiiling of fire extinguisher and AMC Air Conditioning ,water cooler and RO units at RSKP, DDA.
Running, Maintenance and Operation of 11/0.415 KV Sub-Station equipments, DG set, Internal, External and high mast lighting, Submersible pump, Fire equipments, Air Conditioning, Water cooler and RO units at Rohini Sport Complex Sec-14, DDA.
SH- Operation and maintenance of existing 80 HP capacity VRV Airconditioning plant installed at conference hall 12th floor
REPAIR MAINT OF EXTERNAL WATER SUPPLY SERVICES INCLUDING REPAIR/ REPLACEMENT OF VARIOUS TYPES OF MOTORS PUMP SETS PIPE LINES CLEANING AND SUMPS REPLACEMENT OF VARIOUS TYPE VALVES AND OTHER CONNECTED WORK AND REPAIR MAINT OF RO SYSTEMS WITH CONNECTED
ANNUAL MAINTENANCE SERVICES FOR WATER PURIFICATION AND CONDITIONING SYSTEM (Version 2) - Potable Water Purification System Reverse Osmosis Or UV Based; 5 to 7; PACKAGE-4 : Water purifier and conditioning system maintenance involving basic servicing, ... : Water purifier and ...
ANNUAL MAINTENANCE SERVICES FOR WATER PURIFICATION AND CONDITIONING SYSTEM (Version 2) - Potable Water Purification System Reverse Osmosis Or UV Based; 5 to 7; PACKAGE-5 : Water purifier and conditioning system maintenance involving basic servicing, ... : Water purifier and ...
ANNUAL MAINTENANCE SERVICES FOR WATER PURIFICATION AND CONDITIONING SYSTEM (Version 2) - Potable Water Purification System Reverse Osmosis Or UV Based; 3 to 5; PACKAGE-5 : Water purifier and conditioning system maintenance involving basic servicing, ... : Water purifier and ...
ANNUAL MAINTENANCE SERVICES FOR WATER PURIFICATION AND CONDITIONING SYSTEM (Version 2) - Potable Water Purification System Reverse Osmosis Or UV Based; 5 to 7; PACKAGE-4 : Water purifier and conditioning system maintenance involving basic servicing, ... : Water purifier and ...
Desert Cooler powder coated body of size 25 inch x 25 inch x 36 inch height with side panels 03 Nos fabricated out of 20 SWG PGI Sheet, Self supporting stand for evaporative air cooler Desert Cooler of size 25inch x 25 inch x 3inch, SITC stainless ... body RO Water Purifier system ... SITC RO Water Purifier system ...
RMO of Electrical and Mechanical installations at Delhi Secretariat, New Delhi during 2021 22. SH Maintenance and Operation of Package, tower type AC Units, water coolers and Pressurization and vetilation System.
R.M.O. Specialized Electrical and Mechanical Services of Tis Hazari Court Complex, Delhi. (SH Servicing and operation and comprehensive, maintenance of WTAC , STAC, Cassette type Tower type AC units and Water Coolers).
RMO EI and fans, lifts, Sub Station, DG Set, fire alarm, fire fighting system, split Acs and Water Coolers etc. installed at NCC Bhawan, Rohini, Delhi. (SH Comprehensive maintenance of lifts)
Name of works 1 to 3 Running Maintenance, Operation , Comprehensive Maintenance of Split AC/ Window AC/ Cassette AC units , Water Coolers in Vikas Bhawan, IP Estate, New Delhi as per NIT
RMO Specialized Electrical and Mechanical Services of Tis Hazari Court Complex, Delhi. (SH Servicing and operation and comprehensive, maintenance of WTAC/STAC/Cassette type/Tower type AC units and Water Coolers)
RMO various E and M Services installed at Guru Gobind Singh Govt. Hospital, Raghubir Nagar, New Delhi (SH Annual Comprehensive Maintenance of Water Coolers with Inbuilt Purifiers (Make Eureka Forbes /BIOCHEM)
R.M.O. Specialized Electrical and Mechanical Services of Tis Hazari Court Complex, Delhi. (SH Servicing and operation and comprehensive, maintenance of WTAC/STAC/Cassette type/Tower type AC units and Water Coolers).
RMO various E and M Services installed at Guru Gobind Singh Govt. Hospital, Raghubir Nagar, New Delhi (SH Annual Comprehensive Maintenance of Water Coolers with Inbuilt Purifiers (Make Eureka Forbes/ Biochem)
RMO AC Appliances, (ACs, DCs, Refrigerators & water Coolers etc.) installed at the R/o HMPS (LS&RS) bungalows under AC Section SD-III, DED-201, New Delhi. (SITC of Desert Cooler)
Maintenance of various E&M services at Dr. KSSR Stadium, Tughalkabad, New Delhi during 2024-25. (SH- Comprehensive and annual routine maintenance of Industrial RO water filtration units and Water Coolers)
ANNUAL MAINTENANCE SERVICES FOR WATER PURIFICATION AND CONDITIONING SYSTEM (Version 2) - As per tender documents; 5 to 7; PACKAGE-5 : Water purifier and conditioning system maintenance involving basic servicing, filters, membranes, All electrical par..
hot or cold water dispenser Hot Or Cold Water Dispenser ( 10 ) Technical Specifications Specification Specification Name Values Allowed Values Type and Function Type Floor Mounted - Function Hot, Cold and Normal - Test Report Details Availability of test reports from Central Govt./NABL/ILAC accredited Lab covering all the parameters Yes - Test Report No. 35412 - Test Report date 5/8/16 - Name of Test lab USHA - Address of the Test lab. BANGALORE - Material Material of Cabinet ABS FOOD GRADE - Material of cooling water chamber SS - Material of heating chamber SS - Flow Rate and Capacity Flow rate (Litres/hr.) 3.3 Cold water storage capacity (Litres) 2.5 Cooling capacity (litres/hr.) 3 1/3 Hot water storage capacity (Litres) 1 Heating capacity (litres/hr.) 5 Power Consumption Power supply (volts) 230 - Cooling power consumption (Watts) 80 Heating power consumption (Watts) 500 Energy saving mode true Temperature Cooling temperature levels (Degree celsius) 8 Heating temperature levels (Degree celsius) 85 Other Physical Characteristics Tough, durable and corrosion resistant cabinet Yes - CFC free Eco friendly Refrigerant Type Yes - Child lock for hot water for faucet true Drip Tray true true Overheat protection true true Hot and cold water ready indicators Yes - Number of faucets (Nos.) 3 3, 3.0 Over all dimensions (mmXmmXmm) 310 315 934 Net weight (Kgs.) 15.65 Warranty (Years) 1 1, 1.0 * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sunil Kumar 110003, RAJIV GANDHI BHAVAN 10 15 EMD Required No 2/3 ePBG Required No
hot or cold water dispenser Hot Or Cold Water Dispenser ( 25 ) Technical Specifications Specification Specification Name Values Allowed Values Type and Function Type Floor Mounted - Function Hot, Cold and Normal - Test Report Details Availability of test reports from Central Govt./NABL/ILAC accredited Lab covering all the parameters Yes - Test Report No. Re123 - Test Report date 14/07/2018 - Name of Test lab Republic - Address of the Test lab. jammu - Material Material of Cabinet PLASTIC - Material of cooling water chamber PLASTIC - Material of heating chamber PLASTIC - Flow Rate and Capacity Flow rate (Litres/hr.) 5 Cold water storage capacity (Litres) 3.2 Cooling capacity (litres/hr.) 2.5 1/3 Hot water storage capacity (Litres) 0.9 Heating capacity (litres/hr.) 5 Power Consumption Power supply (volts) 230 - Cooling power consumption (Watts) 86 Heating power consumption (Watts) 500 Energy saving mode false true, false Temperature Cooling temperature levels (Degree celsius) 12 Heating temperature levels (Degree celsius) 45 Other Physical Characteristics Tough, durable and corrosion resistant cabinet Yes - CFC free Eco friendly Refrigerant Type Yes - Child lock for hot water for faucet true true, false Drip Tray true true, false Overheat protection false true, false Hot and cold water ready indicators Yes - Number of faucets (Nos.) 3 Over all dimensions (mmXmmXmm) 347x375x990 Net weight (Kgs.) 18.2 Warranty (Years) 1 1, 2, 3, 4 * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Govind Kumar Thakur 110047, O/O The Commandant, 25th Bn SSB Delhi, Ghitorni 25 15
RMO Various E & M Services at West Block - 4 & 5 (Navy), R.K.Puram, New Delhi. (SH :- Supply and installation of RO with water cooler for IHQ - MoD (Navy) offices at West Block -5) Subwork/Packages: Supplying and installation of RO with water cooler for IHQ - MoD (Navy) offices at West Block - 5
Providing electrical staff for day to day maintenance work
SITC of Solar Photo Voltaic power generation system for street light at BDO office
ARMO Intl. EI & Fans, P/Sets., Lifts, S/Stn., DG Set, Fire Fighting, Fire Alarm, PA System, AC Units & Water Coolers at IP Bhawan, New Delhi Subwork/Packages: Supplying & fixing of passive infrared (PIR) technology based occupancy sensor
ANNUAL MAINTENANCE SERVICES FOR WATER PURIFICATION AND CONDITIONING SYSTEM (Version 2) - RO Water Plant For Hemodialysis; 3 to 5; PACKAGE-4 : Water purifier and conditioning system maintenance involving basic servicing, filters, membranes, All electr..
ANNUAL MAINTENANCE SERVICES FOR WATER PURIFICATION AND CONDITIONING SYSTEM (Version 2) - RO Water Plant For Hemodialysis; 7 to 9; PACKAGE-4 : Water purifier and conditioning system maintenance involving basic servicing, filters, membranes, All electr..()
ANNUAL MAINTENANCE SERVICES FOR WATER PURIFICATION AND CONDITIONING SYSTEM (Version 2) - May be refer ATC documents; 5 to 7; PACKAGE-5 : Water purifier and conditioning system maintenance involving basic servicing, filters, membranes, All electrical ..
hot or cold water dispenser Hot Or Cold Water Dispenser ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values Type and Function Type Floor Mounted Table Top, Floor Mounted Function Hot, Cold and Normal Hot and Normal, Cold and Normal, Hot, Cold and Normal Test Report Details Availability of test reports from Central Govt./NABL/ILAC accredited Lab covering all the parameters Yes - Test Report No. URS/TEE/EID/17-18/101 9 - Test Report date 29/12/2017 - Name of Test lab URS Certification Limited - Address of the Test lab. F-3, Sector 6, Noida-201301 India - Material Material of Cabinet plastic Material of cooling water chamber Metal Material of heating chamber metal Flow Rate and Capacity Flow rate (Litres/hr.) 10 1/3 Cold water storage capacity (Litres) 3.5 Cooling capacity (litres/hr.) 5 Hot water storage capacity (Litres) 0.75 Heating capacity (litres/hr.) 5 Power Consumption Power supply (volts) 230 - Cooling power consumption (Watts) 110 Heating power consumption (Watts) 500 Energy saving mode true Temperature Cooling temperature levels (Degree celsius) 10 Heating temperature levels (Degree celsius) 85 Other Physical Characteristics Tough, durable and corrosion resistant cabinet Yes - CFC free Eco friendly Refrigerant Type Yes - Child lock for hot water for faucet true Drip Tray true Overheat protection true Hot and cold water ready indicators Yes - Number of faucets (Nos.) 3 Over all dimensions (mmXmmXmm) 310X345X940 Net weight (Kgs.) 16.7 Warranty (Years) 1 1, 2, 3, 4 * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Suman Lal 110066, East Block-7, Level -6, R.K.Puram New Delhi - 110066 1 15 2/3 EMD Required No ePBG Required No