Loading…
Loading…
9,427 results • Latest
Chlorpheniramine Maleate 2 mg + Levodropropizine30 mg per 5 ml
Coller for direct mounted roller bearing
Parallel shank jobber series twist drill with 4.2 mm.Diameter of %u2018Tool type %u2019 and for right hand cutting. Specification as per IS: 5101/1991 Rev-01. Chemical composition of twist drill shoul
Traction lever to RCF drg. No. 1267508 Ver. 01R3 & specn. No. EN1. 0572. 10025/29 , S355 J2 G3F & Seamless Tube Din 2448, Din1630, St52.4 or Alternate material IS: 1161-79 HFS yst-310 for Drg.No. 1268
Class-III DSC Digital signature certificate along with USB Token for digital signing of documents with validity 02 years.
572500670034- Supply and installation of Digital Signature Certificate (DSC Token) with crypto USB E-Token with validity 02 years to the name of staff mentioned in the authorization letter.
CBC Height Gauge ( Specification As per attached Annexure)
HEAVY DUTY SWITCH DISCONNECTOR 63 AMP DIN TYPE SIEMENS 3KL 8151-3TA10 WITH 63 AMP. FUSE (3 NOS) MODEL 3NA 78 220 RC 500VOLTS OR SIMILAR, AC BREAKING CAPACITY 120 KA CONFIRMING TO IS:13947-3 IS/IEC 609
Supply installation, testing & commissioning of GPS based OHE monitoring & Current collection system Oliver-G. as per RDSO spec No IS/RDSO-TI/0001:2023 or latest along with all accessories/authentic s
COOLED RADIO FREQUENCY TREATMENT ELECTRODE FOR JOINT PAIN RELIEF
COOLED RADIO FREQUENCY TREATMENT ELECTRODE FOR JOINT PAIN RELIEF
Auto Drain Valve
Feeder Junction Box for LHB Type
Supply, installation, testing & commissioning of 08 Ft dia HVLS gearless fan.
Vent Pipe (Hose, Flexible) for Water Line to CIL Part No. AK8060SSfor DEMU & DETC Rolling Stocks.
Procurement of Reference Stanard Samples as per attached technical Annexure-A
Rubber Hose Nominal Dia 70 mm Type B.
Side Sill of LHB coaches
Rubber pad for roof water tank
Parallel clamp assembly 150/160 (consisting of parts parallel clamp 150/160 part No. 1051-3 Qty 02 Nos., Stainless steel M-16X50X38 with nut 1 No., phosphor bronze spring washer B-16. Qty - 1 No.) as per RDSO Drg. No. ETI/OHE/P/1050-3 Mod-A or latest . Make:- CORE/RDSO approved only.
Motor for Machine Room Blower as per CLW Spec. No. CLW/ES/3/0020 or latest
SET OF HARDWARE FOR GEAR CASE
Heavy duty alkaline degreasing agent to IS:6005/98.
Set Of Elastomeric Sealing Rubber
Hex socket head cap screw M12x45 high tensile
Adjuster for brake block BG
BATTERY BOX ASSEMBLY
Mirror holder for LHB coaches as per RCF drg. no. LW62125 Alt-b for LH and RCF drg. no. LW62126 Alt-b for RH ( Quantity 50 % for LH & 50 % for RH ) Matl.&Spec. As per drg.
Inhibitor Corrosion (Compleat EG 50:50 Premixed Coolant) in 205 Litre Container to Cummins Part No. 3816981 or Fleetguard Part No. CC2774 for 1600HP DEMU/DPC.
HQ_Med_(PH NO.8048) LEVETIRACETAM 1 GM TAB
Thin walled flexible elastomeric cable single core etc.
Fastak II suture anchor anchor with Fibe [Fastak II suture anchor anchor with Fiber wire set for bankart surgery - 4 ]
SUTURE LASSO SD -1 , TWIST IN CANNULA-2
Sealing Brush of Length 1905 mm. as per drg. no. 310113.0.21.500.119
MINIATURE CIRCUIT BREAKER, 2.5 AMPS etc.
XLPE Cable for Working Voltage up to and Including 1.1 KV Marked To IS 7098 (Part 1) (Q2) (3 (3 ))
Ajmer Division: Provision of Automatic Fire Detection and Alarm System (AFDAS) at Independent Interlocked LC gates over Ajmer division
JU/Gen-Rewiring of staff quarters, service buildings, station buildings and LC gates & other important locations under SMR & BME power depot of JU Division.
JU/Gen-Rewiring of staff quarters, service buildings, station buildings and LC gates & other important locations under MTD & DNA power depot of JU Division.
Work in c/w provision of S&T service building for interlocking of 08 Nos. of manned LC gates i.e. LC-143, 147A, 147, 137 in MTD- JU Section, LC-25, 18,16 in LN-MJ section and LC-80 in RTGH- DNA section over Jodhpur Division.
ADEN/HQ/II Subdivision - Bank protection work like toe wall, pitching and cess repair works in DO-GGC section.
JU/Gen-Rewiring of staff quarters, service buildings, station buildings and LC gates & other important locations under BGKT power depot of JU Division
Replacement of Bearings & Other miscellaneous Work of Bridge No. 124 (PSC Span-169x18.30m) and ROR 214LA (3x18.30m) Welded Composite in JP division.
Annual Repair Contract (ARC) of FOGPRO make automatic smoke/fire detection system in AC coaches & Automatic fire detection & Automatic/manual Fire Suppression system in Power cars/Pantry cars at coach care complex JU & BME for a period of 03 Years on single tender basis through OEM
Running contract for Manufacturing and Supply of Rail Screw RDSO Drg.No.T- 4153.
9 KVA, 750V/415V/190V AC 3-PHASE, Star Star Star (Yyy), DRY TYPE & AIR COOLED, POWR DISTRIBUATION TRANSFORMER (TYPE-I), SUITABLE FOR USE IN LHB TYPE NON AC EOG COACHES, AS PER RDSO SPECIFICATION No. RDSO/PE/SPEC/TL/0158- 2010 REV(Rev-Nil).