Loading…
Loading…
298 results • Recent activity
lead acid battery Lead Acid Battery ( 32 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Types of Lead Acid of Battery Small sized Valve Regulated Lead -Acid Batteries (SMF) conforming to JISC: 8702/1998 (Part 1, 2 & 3) with latest amendments Small sized Valve Regulated Lead -Acid Batteries (SMF) conforming to JISC: 8702/1998 (Part 1, 2 & 3) with latest amendments Nominal Voltage of Battery (volts) 12.0 Volt 12.0 Volt Material of container Polypropylene Polypropylene Rated Capacity at C20 discharge (AH) 75 75 Warranty (Years) 2 Years 2 Years Battery Condition Charged - CONSTRUCTIONAL Dimensions (L x W x H) (mm x mm x mm) As per relevant IS Specifications - Volume of Electrolyte (ml) 4710 ML 1.120 Sp.Gr - Weight of Dry Battery (Kg) shall be as per relevant IS: Specn., corresponding Ah Yes. - No.of cells per Battery (No.) 6 Cells for 12 Volt battery - 1/3 CERTIFICATIONS Availability of Test Reports from Central Govt./NABL/ILAC accrediated Lab showing conformity to the specifications Yes - Address of the Lab AHMEDABAD - Name of the Lab EXIDE BANGLORE - Test Report No. 12345678 - Test Report Date 21/12/2017 - Compulsory Registration (CRS) of BIS for safety as per IS 16046 as applicable. Secondary Cells and (Batteries containing Alkaline or other non- acid Electrolytes-Safety Requirements for Portable sealed secondary cells, and for Batteries made from them for use in portable applications YES - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 AMIT SHARMA 462001, Old Secretriate, Collector Office Bhopal 32 15
lighting pole or post and hardware- tubular street light poles Average Turn Over of Last 3 Years 50 Lakh (s) Experience with Gov. Required 2 Year (s) Lighting Pole Or Post And Hardware- Tubular Street Light Poles ( 40 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Tubular steel poles shall be conforming to IS 2713/80(Part-1& 2) with amdt No-1 latest Yes - Designation of Tubular steel poles as per table 2 of IS 2713/80 Part-2 with amdt No 1 410SP-80 As per GeM Catalogue. Length of Tubular steel poles (Metre) 7.5 7, 7.5, 8, 8.5, 9, 9.5, 10, 11 Coating on the tubular steel poles Bitumen coated as per clause 13.1 of IS:2713 part 1/1980 Galvanised min. Mass of Zinc coating 360 Gms. sq. Mtr., Bitumen coated as per clause 13.1 of IS:2713 part 1/1980 BIS Marked No Yes, No If Yes, Declare BIS License Number, If No Write Not Applicable - - CONSTRUCTIONAL Type of steel poles Swaged (SP) - 1/3 Finials, Base plates and taper plug shall be as per clause 15 of IS 2713(Part-1)/1980 YES - Grade of steel tube, as per IS:1161/1998 YST 240 - CERTIFICATIONS Availability of Type Test Reports of the product from Central Govt/NABL/ILAC accredited Lab showing compliance to the specification YES - Test Reports No. - - Test Reports Date - - Name of the Labs - - Test report and approvals to be furnished to the buyer on demand. YES - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Manoj Kumar Malav 325220, NAGAR PALIKA CHHABRA 40 15
OEM Cartridge/Consumable OEM Cartridge/Consumable ( 50 ) Technical Specifications Specification Specification Name Values Allowed Values Specification Product Class OEM - Brand HP - Type of Cartridge/Consumable Toner - Colour of Cartridges/Consumable s Black - Ink/Toner/Drum Model number HP 88A Black Original LaserJet Toner Cartridge - Corresponding Part number/code CC388AC - Printer Model number/numbers for which Cartridge is suitable HP LaserJet M1136 MFP Printer, HP LaserJet M1136 MFP Value Bundle, HP LaserJet M1213nf MFP Printer, HP LaserJet M1216nfh MFP Printer, HP LaserJet P1007 Printer, HP LaserJet P1008 Printer, HP LaserJet P1106 Printer, HP LaserJet P1108 - 1/3 Printer, HP LaserJet Pro M1218nfs MFP Printer, HP LaserJet Pro M202dw Printer, HP LaserJet Pro M202n Printer, HP LaserJet Pro MFP M126nw Printer, HP LaserJet Pro MFP M128fn Printer, HP LaserJet Pro MFP M128fw Printer, HP LaserJet Pro MFP M226dn Printer, HP LaserJet Pro MFP M226dw Printer Yield of the Cartridge as per ISO/IEC:19752/2 004(E)for BK & ISO/IEC:19798/2007(E) for colour (Numbers) 1500 - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 irfan siddiui 226016, SIHFW Campus, Training Block-2, C- Block Indira Nagar 50 15
Line Intractive UPS with AVR Line Intractive UPS With AVR ( 10 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 2.0/800 As per GeM Catalogue. Technology MOSFET-PWM MOSFET-PWM, IGBT- PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1, 2 &3 SMF-VRLA confirming to JISC-8702 Pt 1, 2 &3 Rated Output (Volt) Single Phase Quasi-Sin- wave 230 V AC, 50 Hz Single phase sinewave 230v AC, 50Hz, Single Phase Quasi-Sin-wave 230 V AC, 50 Hz Degree of protection IP-21 IP-21, IP 20 Inverter Efficiency (%) >/= 60% >/= 60%, >/= 70% Warranty for the battery from the date of delivery 1 year 1 year, 3 Years Warranty for Line Interactive UPS 1 Year 1 Year, 2 Years, 5 Years, 3 Years Installation and commissioning instructions No - CONSTRUCTIONAL Type of enclosure Mild steel - AC out put for No Yes, No 1/4 printer (not through inverter) Inverter out put socket AC out put for printer (not through inverter) 2 Three pin 2 Three pin, 3 Three pin, Hard wiring, Not applicable FUNCTIONAL Total harmonic distorsion (%) </= 40% - Input (Volt) Single phase sinewave(160-280v) - Switching over time (Mili sec) Maximum 10 milli seconds - Overload Time (Minutes) >/= 10 minutes - Load power factor >/= 0.6 - Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9%, 50 +/-3 Hz - Overload (%) >/=10% - Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% - Variation on output frequency in battery mode (Hz) </=0.5 - PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 - Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts, the system shall switch over to battery mode Yes - Protection against short circuit of UPS Yes - Protection for over voltage and over load Yes - REPORTS AND CERTIFICATIONS Damp heat Test at 45 degree, RH -95% for 2-cycle as per IS:9000 pt-5/sec-1 Yes - Dry heat Test at 45 Yes - 2/4 degree for 16 Hrs as per IS:9000 pt-3/sec-5 Cold Test as per IS:9000 pt-2/sec-4 Yes - Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes - Type Test certificate no. and date - - Name Of Lab - - Address of Lab - - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Not applicable presently - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Santosh Kumar Khabile 416416, Sangli - Miraj Road 10 15
Vehicle Hiring Service (Long Term)