Loading…
Loading…
644 live235 closing this weekmost from South Coast Railway and Indian Railways
644 results • Latest
Repairs to road surfaces at Level crossing gate approaches and Railway Colonies between IPM-VZM section under the jurisdiction of Sr.DEN/East/VSKP
GTL div: Modification of OHE arrangement at loop lines and crossovers in view of eligibility improvement of OHE in GTL-RU section
GTL div: Up-gradation of OHE/PSI infrastructure to improve reliability and safety in GY-DMM, GTL-RU section-POH of Transformers
Custom Bid for Services - Schedule A Hiring of material transport vehicle Lorry of 6 to 7 point 5 Tonne pay load capacity with 1800 km per month per vehicle with long steel body in good working condition of Two nos for OGL and RJY depots each for a .., Custom Bid for Services - Schedule B Hiring of material pickup multi utility vehicle of 1 to 1 point 25 tonne pay load capacity of Four nos for BZA BPP NLR TUNI depots each for a period of two years Similar Category Goods Transportation service - Monthly Based Service Monthly Basis Cab & Taxi Hiring Services
Digital Electronic Spirit Level (Digilevelor Digitalinclinometer) (Q3)
Monthly Basis Cab & Taxi Hiring Services - SUV; 2000 KM PER MONTH AND 24000 CUMMULATIVE KM PER YEAR; Outstation 24*7
ROH attention of 200 wagons at the premises of wagon workshop, Guntupalli, South Coast Railway.
Set of items, set consists of two items asdetailed below: 1) BOLT HEX HEAD 3/8-24 x 3/4 to EMD Partno. 454911 Alt"B" or latest, DLW Part no.19012299. Qty - 1000Nos. 2) WASHER SPECIAL: 3/8, as per EMD Part no. 8373316Alt"B" or latest, DLW Part No. 19394147. Qty - 600 Nos.
BOLT HEX HEAD, SIZE: 1/4 -20 X 3/4 OILLINE TO EMD PART NO. 179795 Alt "E" OR LATEST
Set of 02 items as detailed: (1) Bolt tosize: 9/16 -18 x 3-1/2" to BLW part no:19011260 and EMD DrgNo. 181465 Rev C or latest, Qty-100 Nos. (2) NUT HEX Lock9/16-18 to BLW part no. 19354230 and EMD Drg No. 9416519Rev- B or latest, Qty-100 Nos.
BOLT Hex head 1/4-28 x 5/8 -Oil line toRocker Arm Shaft as per EMD Pt.No.181311 Alt"Da" or latest and BLW Pt.No.19010059
BOLT Hex head 1/2-13 x 1-1/2 to EMD Drawing No. 179885 Alt-E or latest.
AIR CIRCUIT BREAKER(ACB) SUITABLE FOR LHB POWER CAR OF SYSTEM VOLTAGE- 750 V , CAPACITY-800 AMP , BREAKING CAPACITY - 50KA , FREQUENCY- 50 HZ, 3 POLE MF( WITH INBUILT UV PROTECTION , THERMAL ,MAGNETIC RELEASE, 6 NO+ 6 NC AUX CONTACT BLOCK AND DRAW-OUT ACBS TERMINAL ADAPTORS) SIMILAR TO L&T MAKE ACB TYPE : CN-CS 800C CONFORMING TO RCF SPECIFICATION NO : EDTS 103 , REV-D, AM-07 OR LATEST, MAKE- LAURITZ KNUDSEN FORMELY L&T /ABB /GE ONLY. Note: Sample should be got approved before bulk supply. ONLY OEM or its authorized dealers to participate
Comprehensive Annual Maintenance Contract of M/s. Laxven make Microprocessor based control and Fault Diagnostic System (MPCS) version "V3" fitted in Conventional Electric Locomotives for a period of 02 Years through OEM at Electric Loco Shed, Guntakal
GNT Division- Replacement of rusted cantilevers, over-aged insulators and composite insulators.
GNT Division-Replacement of Leaning/critical and less contact wire height OHE structures due to raising of track with new OHE structure.
Electrification works in connection with "Raising of High level platforms 02,03&4 and 05 platforms at ALM and KPL stations over Main line
Provision of 11KV/750V Sub-stations, 2Nos. for extending power supply for maintenance of LHB rakes at Coaching Depot, Visakhapatnam
HRC fuse link (low voltage), Din type, current rating 100A, 500V AC, breaking cap 100KA, Conforming to to IS:13703 pt.2 & RDSO Spec.No.RDSO/PE/SPEC/AC0184- 2015 (Rev.1)
Supply of Cylindrical HRC Fuse link 2 Amps, 500V AC, size 10x38 mm breaking capacity 120KA confirming to IEC 60269-2 suitable for secondary circuit of 100VA Control transformer of Non-AC LHB Coaches conf to RDSO Spec.No. RDSO/PE/SPEC/ AC/0203-2020 (Rev.0) Makes: Bussmaan (Eaton), L & T, Siemens, Siba, Ferraz, , EFEN, ETI and ABB Note:- One sample to be got approved before bulk supply
Retro-Fitment type 5W LED lamp in place of 11W CFL wash basin conforming to ICF Specification no. ICF/Elec/960 Rev.0 or latest.
Periodical maintenance by providing Distempering, painting, emulsion to Staff Quarters , Service buildings, platform shelters, FOB's, water tanks etc from PDU to KUK stations on Main Line under the jurisdiction of Sr.DEN/East/VSKP.
Miscellaneous P.way works like improvement of drainage, section & yards ambiance, standardization of level crossings, updating of track and road sign indicator boards, ballast profiling, Stacking of released materials for the purpose of scrap offer, machine tamping operations, greasing of assets etc., under the jurisdiction of Sr.ADEN/VZM of VSKP division.
Miscellaneous P.way works like improvement of drainage, section & yards ambiance, standardization of level crossings, updating of track and road sign indicator boards, ballast profiling, Stacking of released materials for the purpose of scrap offer, machine tamping operations, greasing of assets etc., under the jurisdiction of ADEN/PSA of VSKP division.
Anti-corrosive painting of rail on running track with Bituminous paint as per IRPWM from IPM-PSA under the jurisdiction of ADEN/PSA of VSKP Division.
Monthly Basis Cab & Taxi Hiring Services - MUV; Guntakal Division Hiring of Non AC base Model Pickup Van (MUV) of 1 tonne & above capacity to SSE/TRD/HGI Depot for OHE/PSI Breakdowns and Inspections for a period of 24 Months; Outstation 24*7
Goods Transportation service - Monthly Based Service - Outside state; Railway Goods; Open Body LCV Truck
Monthly Basis Cab & Taxi Hiring Services - SUV; Hiring of Road vehicle for official use of SrDEE/TRD/GTL for a period of 36 months; Outstation 24*7
Monthly Basis Cab & Taxi Hiring Services - MUV; Guntakal Division Hiring of Non AC base Model Pickup Van (MUV) of 1 tonne & above capacity to SSE/TRD/RJP Depot for OHE/PSI Breakdowns and Inspections for a period of 24 Months; Outstation 24*7
Monthly Basis Cab & Taxi Hiring Services - MUV; Guntakal Division Hiring of Non AC base Model Pickup Van (MUV) of 1 tonne & above capacity to SSE/TRD/DHNE Depot for OHE/PSI Breakdowns and Inspections for a period of 24 Months; Outstation 24*7
Online Dissolved Gas Analysis (DGA) Monitor for Transformer Oil
Fire extinguisher - 6kg capacity , ABC dry chemical powder SS body with stored pressure (without anti-theft mechanism) conforming to RCF Specification No. MDTS-46270 Rev- no: 06, Corrigendum-1 along with hanging brackets on fire extinguisher as per RCF Drg. no. CC64262, Item-2, alt-f.
S&T portion of work in connection with proposed ROB/LHS at various LC Gates ML- 456, ML-453, ML-460, ML-466, ML-469, RV-278, RV-274, ML-442, RV-290, RV-291, RV-292, RV-317, VM-4, ML-446 & ML-447 and RUB/LHS at Km 862/29A-31A.