Loading…
Loading…
647 live291 closing this weekmost from South Coast Railway and Indian Railways
647 results • Latest
Lifting table hydraulic with wheel for Lifting of after cooler as per attached specifications.
Capacitor for rectifier AC damping to part no: ASPR- 38 2598N50, 50.0000 μF +/-10% 900 VAC SIZE: 105MM(W)x155MM(L)x135MM(H)xMETAL BOX WITH CLAMP AND(M8x30) BRASS SCREW TERMINALS TERMINALS PITCH - 50MM.
Supply of Portable Bearing checker with in-built shock pulse probe and infrared temperature sensor complete with 02 Nos. AA batteries and headphone of make SPM Instrument, model BC- 200 or MCM instruments or its similar as per specification details mentioned in the attached document.
Center Roof fixing bolt as per ELS/BZA/S.C.Rly Drg. No. B/TRS/Aux/4/361, Ref nos. 01 to 06(each one number) for 3 phase locos.
Monthly Basis Cab & Taxi Hiring Services - SUV; 3000 KM PER MONTH AND 36000 CUMMULATIVE KM PER YEAR; Outstation 24*7
Goods Transportation service - Monthly Based Service - Outside state; Railway Materials; MUV Pickup van, Goods Transport Service – Per KM Based Service - Railway Materials; Non-AC base Model MUV (Pick up Van) of loading capacity one MT with sitting capacity of 4/6 persons; Non-AC base Model MUV (Pick up Van) of loading capacity one MT with sitting capac..
Set of Rail Guard (One Set consisting of following items) (1).Rail Guard LHS & RHS one each as CLW Drg. No. 03/04/62/67. (2).Make up piece . Qty. 04 Nos. per set as per CLW Drg. No. 03/04/62/82. (3). Bolt size 16x100 m.m. with nut, 01 plane washer & 01 spring washer . Qty. 04 Nos. per set. (4). Bolt size 16x70 m.m. with nut, 01 plane washer & 01 spring washer. Qty. 04 Nos. per set. Material : Bolt -IS : 1364/67, Grade 8.8/10.9 Make LPS/TVS/VIF/Unbrako or its equivalent. Spring Washer IS-3063/94,Plain Washer IS-2016.
"Plasticised polyvinyl chloride (PVC) Non-thermo setting pressure sensitive adhesive Tape (General purpose type) for electrical purpose, size 20mm Width X 0.125mm thickness, in Length of 10 meters, confirming to IS:7809 (Part-1/75, Part.11/77 and Part-III-Sec-1/86) or latest."
HANGER LEVER (END) FOR AIR BRAKE GEAR OF WAG7 LOCO TO CLW'S DRG NO O6/3/19/1O,ALT- 5.WITH BUSHES CONFORMING TO Mn. STEEL IRS R- 65.(As per UVAM ID:2101027).
SET OF CYLINDER LEVER ASSEMBLY CONSISTING OF ONE LH AND ONE RH AS PER CLW DRG.NO.06/3/19/11 ALT.3 (As Per UVAM ID:2101027).
Modified slack adjuster bottom as per Drg. no. ELW/ BSL/ 4/ WAG-7/ 002 (Sheet no. 1/ 2) for providing in Electric locomotives (As per UVAM ID:2101027).
LSGRT LIGHT (RED LED) SUITABLE FOR EXISTING FITMENT IN ELECTRIC LOCO (WAG-5 WAG-7 and WAP-4) OPERATING VOLTAGE RANGE 87V DC TO 140V DC, NORMAL VOLTAGE 110V DC (with Reverse polarity ).ONE SAMPLE TO BE GOT APPROVED BEFORE EFFECTING BULK SUPPLY.
HANGER PIN AS PER CLW DRG. NO.06/4/19/127,FOR WAG-7.(As per UVAM ID:2101026).
HOSE ASSEMBLY. Water inlet vent - Includes swivel fittings to DLW Pt No.17051113 and EMD Pt No.9579999 Alt "b" or latest.
Set of modified sander pipe for WAG9 loco as per Drg. No. ELS/VSKP/2016/24, Alt-b, One set consists of (1) Pipe-RH (Sl.No.-1 of drg)Qty- 1 No/Set (2) Pipe-LH (Sl.No.-1 of drg)Qty- 1 No/Set (3) Jublee Clamp for Hose Pipe(Sl.No.-7 of drg) Qty- 6 nos/Set. (Note: One set of sample approved before bulk supply.)
1/2 INCH FLAT WASHER AS PER EMD PART NO 6101229 Alt "D1" OR LATEST AND DLW PART NO.19393040 .
Signal Zonal work under the jurisdiction of SSE/SIG/CHE in Visakhapatnam Division.
Guntakal Division - SW-(I) :Kadapa: Proposed construction of Type IV Quarters 02 units (01 unit each for ADEN/HX, SSE/PWAY/HX ) . SW-(II):Anantarajupet and Pullampet : Proposed construction of Type-II quarters 8 units for trackmen (4 units at each station).
Guntakal Division - SW-(I) :Nandaluru: Construction of New Running Room (50 beds) with all facilities. SW-(II):Nandaluru: :Construction of Crew Lobby office with all facilities.SW-(III): Construction of RPF outpost building at Rajampeta.
Guntakal Division - SW-(I) :RENIGUNTA - Upgradation of Running Room building by providing all specified facilities with 75 bed capacity (A/c). SW-(II): Renigunta: :Construction of Crew Lobby office with all facilities.
Guntakal Division: Sr.DEN/South Jurisdiction : Proposed Central Drain Between UP & DN Main Lines Tracks at Km: 221/500-222/500 at NRE - MMPL Station in SSE/P.Way/NRE Section.
Guntakal Division : Sr.DEN/South Jurisdiction : Earth work / Cess Repairs in recouping the formation in Isolated stretches for a quantity of 35222.50Cum in SSE/P.Way/HX Section.
GTL Div: Electrical Arrangements- 1. Raising of Platforms to High Level and Provision of New 3m FOB at CCI,TKU,TAT,DCU and KBA stations.2.Raising of Platforms to High Level at MPT,NCE East and PCL stations.
GTL Div: Electrical Arrangements- 1.Raising of Platforms to High Level and Provision of New 3m FOB at LMD,TGL and JKO stations.2. Raising of Platforms to High Level at PDL, JUR and RLO Stations.
Guntakal Division- Electrical arrangements- Marichetal- Raising of Platforms to High level and Provision of New 3M FOB at Marichetal station.
Design, supply, installation, commissioning and testing of no-load
Supply of "Set of Pins for Brake Rigging of WAG-7 Locos. Each set consisting of 9 pins of material as per RDSO Specification IRS:R-65 including item No.3 irrespective of material mentioned in Drawing No. 06/4/19/126 (As Per UVAM ID:2101026)."
Calibration of Inspection, Measuring and Testing Equipments (IMTEs) for a period of Three years in Carriage Repair Shop, Tirupati
Carrying out repairs to Telecom maintenance assets of Vijayawada division for period of one year.
Repairs to Staff Quarters like Roof Leakage, sunshades, Doors, windows, Cup boards, fly proof mesh, Floor tiles ,Periodical paintings etc. under the jurisdiction of ADEN/PSA.
Brake Head for WAP-4 locos as per CLW Drg. No. 03/2/19/3 Alteration-3. (As per UVAM ID:2101027).
Repairs to road surfaces at Level crossing gate approaches and Railway Colonies between IPM-VZM section under the jurisdiction of Sr.DEN/East/VSKP