Annual Maintenance of Electrical Installation Works at the Special Correctional Home and Adjacent other Government premises at Jhargram
A.3 Corrective / Breakdown Maintenance The agency shall: Attend and rectify all electrical faults within the scope of work with absolute promptness. Rectification of any abnormality noticed during Preventive maintenance. Repair all types of light fittings and fixtures, all types of fans (excluding rewinding) Replace defective Fans, Fittings & Fixtures and any other Electrical/ Electro-mechanical Items using department-supplied materialsincluding dismantling/ taking down and re-fixing of the same. Replacement of materials either consumable or non-consumable such as fluorescent tubes, lamps, chokes, starters, holders, HRC fuse links, MCB's, isolators, switches, sockets, cable connections & terminations etc. All minors repairs, adjustment of relays, timer etc. Restore power supply in case of breakdowns using available or temporary arrangements, till completion of restoration work. Maintain records of faults, repairs, and restoration time Respond promptly to all complaints and instructions from EIC / AE / JE
Annual Comprehensive On-Site Maintenance of entire Air Conditioning Machines installed within Hospital College Campus of NBMCH, Darjeeling, for one year.
Annual Comprehensive & Preventive Maintenance (all inclusive) of Air-conditioning machines with all type of spare materials like-all type of Referigarent Gas, All type of capacitor , All type of Compressor ,All type of PCB Board & others materials whitch required for maintenance Total no of AC (2T)=62 Nos Total capacity-62x 2 TR.=124TR Time Period=12 Months Total Qty =124x12=1488TR
Repair and maintenance of subordinate rest house at 220kV substation HVPNL colony Rewari.
Repair and maintenance of subordinate rest house at 220kV substation HVPNL colony Rewari.
REPAIR AND MAINTENANCE OF AMMA UNAVAGAM IN PANRUTI MUNICIPALITY
Goods and Service Tax @ 18%
Repair and Upgradation of Maintenance facilities at TKD Yard
Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below,350 RPM (tolerance as per IS : 374-2019), THD 55 (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 or latest fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 1400mm, service value greater then equals to 6.0CM/Min/Watt, air delivery 245 CM/Min (Minimum)
Maintenance and repair of street lights and electrical lines