Loading…
Loading…
2,192 results • Best match
Construction of 2 Nos. Rainwater Harvesting Systems in Sector-3 (near Housing Board and Green Belt opposite CM House), Ward No. 13, MC Thanesar.
[33.19]Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by `V` notch method or any other approved method, measuring static level and draw down etc. by step draw down method, collecting water samples and getting tested in approved laboratory, i/c disinfection of tube well, all complete, including hire and labour charges of air compressor, tools and accessories etc., all as per requirement and direction of Engineer-in-charge. [Through Rate]
BAGA NADI FAIL TUBE WEL KE STHAN PAR NAYE TUBE WEL NIRMAN KARYA GRAM DASNOO GRAM PANCHAYAT RAISAR
Construction of Tube Well up to 100 mtr. depth in all type of rocks by DTH system & over burden to accommodate casing pipe of following sizes in all types of soils & over burden including lowering of casing pipes, (if required) excluding cost of casing pipes, as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended upto date) and technical specifications. The work would be completed after obtaining sand free water. The tube well should have a through out bore as per nominal dia of casing pipe. 250 mm dia
Mtc of Switch, Kit, kat (63Amp - 100 Amp) , ceiling fan, Starter oil, Panel Board complete (Starter, Ampere meter, volt meter etc.) Submersible cable of size 4 sqmm to 12 sqmm aluminnium cable from elect. pole to Panel board for tubewells and 16mm to
-Mtc of Switch, Kit, kat (63Amp - 100 Amp) , ceiling fan, Starter oil, Panel Board complete (Starter, Ampere meter, volt meter etc.) Submersible cable of size 4 sqmm to 12 sqmm aluminnium cable from elect. pole to Panel board for tubewells and 16mm to 25 sqmm for boosting station etc. UGT, with painting work etc. repair of AC/PVC/DI, GI pipe line consumable items i.e. Grease, Cotton, Rubber sheet, Nut Bolts, Lubricating Oil , Glan Dori , lowering and lifting of submersible motor pump, including cartage loading and unloading, chainpully, Repair/ replacement/ increasing of G.I. lowering pipe of size 50 mm to 80 mm, disconnecting of illigal connection and regularise connection with ferrule connection with repair and replacement of NRV,Sluice Valve from Tubewell and B/Station delivery to the Tailend of pipeline along with Leakage repair, Jointing of All DI Pipeline (AC/PVC/DI/GI Pipes) etc complete in all respect with the entire satisfaction of the Engineer-in-Charge and all other works contingent thereto.` (O and M for 3rd Year)
Mtc of Switch, Kit, kat (63Amp - 100 Amp) , ceiling fan, Starter oil, Panel Board complete (Starter, Ampere meter, volt meter etc.) Submersible cable of size 4 sqmm to 12 sqmm aluminnium cable from elect. pole to Panel board for tubewells and 16mm to
-Mtc of Switch, Kit, kat (63Amp - 100 Amp) , ceiling fan, Starter oil, Panel Board complete (Starter, Ampere meter, volt meter etc.) Submersible cable of size 4 sqmm to 12 sqmm aluminnium cable from elect. pole to Panel board for tubewells and 16mm to 25 sqmm for boosting station etc. UGT, with painting work etc. repair of AC/PVC/DI, GI pipe line consumable items i.e. Grease, Cotton, Rubber sheet, Nut Bolts, Lubricating Oil , Glan Dori , lowering and lifting of submersible motor pump, including cartage loading and unloading, chainpully, Repair/ replacement/ increasing of G.I. lowering pipe of size 50 mm to 80 mm, disconnecting of illigal connection and regularise connection with ferrule connection with repair and replacement of NRV,Sluice Valve from Tubewell and B/Station delivery to the Tailend of pipeline along with Leakage repair, Jointing of All DI Pipeline (AC/PVC/DI/GI Pipes) etc complete in all respect with the entire satisfaction of the Engineer-in-Charge and all other works contingent thereto.` (O and M for 3rd Year)
AMC for all types of Pumps, Metro Railway, Kolkata for 5 years
2-Break Down Maintenance of Dewatering & Tube well Pump as and
Providing, Installation, Testing and Commissioning of Electric Chain Pulley Block of 5 Ton Capacity along with allied electro-mechanical works to be installed at T/well Dental College under JMC Capex (New Works) 2026-27.
Providing, Installation, testing and commissioning of Electric Chain Pulley Block of 5 Ton capacity alongwith allied electromechanical works to be installed at Tube Well Dental College as per following specification:- Electric chain hoist are designed as per IS:- 6547 Capacity:- Hoisting speed Mt/min:- 2Mtr/min HP of the motor:- 2 HP Construction:- Hoist should be of unique modular construction which makes them an ideal choice since each sub assembly is easily accessible individually, thus reducing the time and cost involved in the maintenance. Frame:- The frame is of sturdy design, fabricated from tested steel plates and is welded/bolted type. Gear Box:- Totally enclosed gear box with gears made from EN-9/EN-24, steel and teethed on precision hobbing machine, hardened and tempered. The gears are le and need no further lubrication. Electric Motor:- 3 Phase, 440 volt AC 50 cycles, squirrel cage induction motor. Load Chain:- Conforms to IS:- 6216-1971, Grade 80, Tested, Calibrated and duly heat treated. Brake:- Instant action fail to safe, electromagnetic disc brake are incorporated to ensure maximum safety and reliability in operation. Unit Switch:- Snap action limits switches are used to prevent over hoisting and over lowering. Control Panel:- Totally enclosed dust and moisture proof panel housing with components of standard makes provides control at low voltage for safety of operator. Hooks:- Steel forge conforming to IS:- 8610-1977. Free to rotate and swivel. Test:- Each hoist is tested to 25% over load with conformation to IS:- 6547-1971. Job also include providing, installation, testing and commissioning of MCCB (switch fuse unit) 4 pole of 250 ampere and 95 sq.mm Aluminum armoured cable 3.5 core 10 mtrs. in length with MCCB of 200 ampere (4 pole) for L.T. Control Panel alongwith allied works to be installed at Tube Well Dental College.