Loading…
Loading…
2,583 results • Best match
Electrical Installation cum renovation and modification type Electrical work for converting the reading room at the ground Floor situated just right side of the Judges Lift into one full-fledged Conference Room at Main Building of the -- AC Work ....
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works (E-16 / 7) a) 25 mm size
Renovation of Brick Line Canal at Manya Kumar Para DTW Scheme under Water Resource Sub Division Gonda Twisa during the year 2026 27 SH Maintenance of Brick Line Canal at Manya Kumar Para DTW Scheme under Raishyabari R.D Block.
M/o STP (Existing STP based on SBR Technology core Parts (Decanter core part, diffuser, PLC SCADA and Related work) (Renovation and Strengthening work of the existing 50 MLD STP Core Parts with MPS at Sector-168) Noida (PART-A)
d) Replacement/Repairing of air line from blower discharge to SBR Unit & all complete work as above items. direction by Engineer-in-charge e) Replacement of RAS/SAS Pumps unit –8 Nos RAS Pump Capacity - 365 m3/hr @0.60 Kg/cm2, @ 10m head SAS Pump Capacity - 75 m3/hr @ 10m head Type-Submersible Non Clog Speed-Less than 1000 RPM Handle Solid Size 100mm Specific Gravity - 1.05 Operation start and stop automatically based on the level in the wet well (VFD Suitable), Motor Cooling System - Cooling Jacket Accessories Lifting Chain Bow Shackle at every Im -10m Length each Pump Guide Pipe with square Guide rail bar 10m Length each Pump Cable Length - Min. 20m All required Pump Protection Water Leakage Detector, Bearing Temperature Detector, Thermal Overload Protection, Seal Detector etc & all complete work as above items. direction by Engineer-in-charge f) Replacement/Repairing of corroded cable & cable trays & all complete work as above items. direction by Engineer-in-charge g) Repair work of Actuators, Provision of pump lifting arrangement & other miscellaneous works & all complete work as above items. direction by Engineer-in-charge .
M/o STP (Existing STP based on SBR Technology core Parts (Decanter core part, diffuser, PLC SCADA and Related work) (Renovation and Strengthening work of the existing 33 MLD STP Core Parts with MPS at Sector-54) Noida (PART-C)
c) Replacement of Coarse Screens 2 Nos Screen Chamber Size : 0.9m wide x 4.5m Long x 0.9 mSWD + 0.5 m FB Avg. Flow to Each Screen-16.50 MLD Peak Flow to Each Screen-37.125 MLD Type Inclined Multi Rake Bar Screen Angle of Inclination - 75 deg. Clear Opening -20mm Flat Size 20x 10mm Bar Profile Rectangular Operating Height/Chanel Depth - 5 m & all complete work as above items. direction by Engineer-in-charge d) Cleaning & Desilting of Sump well size- 11.0 m Dia. x 2.50 m SWD & all complete work as above items. direction by Engineer-in-charge e) Replacement/Repairing of Electrical Control Panel along with Cabel & Cabel Trays & all complete work as above items. direction by Engineer-in-charge f) Repair Work of inlet, outlet & Bypass gate Valves, Belt Conveyars & EOT Crane & all complete work as above items. direction by Engineer-in-charge
M/o STP (Existing STP based on SBR Technology core Parts (Decanter core part, diffuser, PLC SCADA and Related work) (Renovation and Strengthening work of the existing 35 MLD STP Core Parts with MPS at Sector-123) Noida (PART-D),
c) Replacement of Coarse Screens 2 Nos Screen Chamber Size : 1.3m wide x 6.5m Long x 1.3 mSWD + 0.5 m FB Avg. Flow to Each Screen-17.50 MLD Peak Flow to Each Screen-39.375 MLD Type Inclined Multi Rake Bar Screen Angle of Inclination - 75 deg. Clear Opening -20mm Flat Size 20x 10mm Bar Profile Rectangular Operating Height/Chanel Depth - 5 m & all complete work as above items. direction by Engineer-in-charge d) Cleaning & Desilting of Sump well size- 12.50 m Dia. x 2.50 m SWD & all complete work as above items. direction by Engineer-in-charge e) Replacement/Repairing of Electrical Control Panel along with Cabel & Cabel Trays & all complete work regarding above items.as direction by Engineer-in-charge f) Repair Work of inlet, outlet & Bypass gate Valves, Belt Conveyars & EOT Crane & all complete work as above items. direction by Engineer-in-charge
M/o STP (Existing STP based on SBR Technology core Parts (Decanter core part, diffuser, PLC SCADA and Related work) (Renovation and Strengthening work of the existing 25 MLD STP Core Parts with MPS at Sector-50) Noida (PART-B)
c) Replacement of Coarse Screens 2 Nos Screen Chamber Size : 0.8 m wide x 4.0m Long x 0.8 mSWD + 0.5 m FB Avg. Flow to Each Screen-12.50 MLD Peak Flow to Each Screen-28.125 MLD Type Inclined Multi Rake Bar Screen Angle of Inclination - 75 deg. Clear Opening -20mm Flat Size 20x 10mm Bar Profile Rectangular Operating Height/Chanel Depth - 5 m, & all complete work as above items. direction by Engineer-in-charge d) Cleaning & Desilting of Sump well size- 11.0 m Dia. x 2.50 m SWD & all complete work as above items. direction by Engineer-in-charge e) Replacement/Repairing of Electrical Control Panel along with Cabel & Cabel Trays & all complete work as above items. direction by Engineer-in-charge f) Repair Work of inlet, outlet & Bypass gate Valves, Belt Conveyars & EOT Crane & all complete work as above items. direction by Engineer-in-charge