Loading…
Loading…
2,722 results • Best match
Providing additional 3rd 5 MVA, 33/11kV power transformer at 33/11kV sub-station Horti in Indi Taluk, Vijayapur District in 33KV S&L Division, Vijaypur on PTK basis (5 MVA Power Transformer will be supplied by departmentally).
240 Sqmm, (55 GI Wires - 3.15 mm Dia) 11 kV, 3 Core, XPLE HTUG Cable Laying of cable in trench Kms 0.1 58500.00 5850.00 COST DATA SHEET - 21 #REF! #REF!
REPAIR MAINT OF LT SUPPLY SYSTEM EXTERNAL ELECTRIFICATION AND CONNECTED MISC ITEMS OF WORK AT PEDONG ALGARAH AP ALGARAH DALAPCHAND AND TEESTA TCP UNDER GE 867 EWS
Supply and lay DWC Cable duct pipe of size 40 mm dia confirming to IS : 16205 part 24 for laying of LT cables etc complete with all accessories all as specified and directed.
PROVISION OF EXTERNAL SERVICES (EXTERNAL WATER AND ELECTRIC SUPPLY) FOR MAP PHASE 2 AT AF STN MUMBAI UNDER GE(AF) THANE
Excavation in trenches n. exc. 1.5 M in width and 1.5 M in deep for laying of cables and getting out in Soft / loose soil complete all as specified and directed.
Construction of 2 Nos Permanent Courts at Second Floor of Judicial Block and Flat for Judical Officers Stilt 2 Storey in Judicial Court Complex Ajnala
XLPE INSULATED ARMOURED CABLES (UNDERGROUND): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988 to be laid 1metre below ground level including excavation, sand cushioning, covering with sand & First Class bricks and back filling the trench etc., of the required size as per PWD General Specifications:-
CONSTRUCTION OF SHRI GURU RAVIDAS BANI ADHYAN CENTER VILLAGE AT FARIDPUR - NAUGAJJA DISTT. JALANDHAR (PUNJAB) (PHASE-I)
XLPE INSULATED HT ARMOURED CABLES (UNDERGROUND): Supply & laying of Circular Aluminium Conductor screened with extruded semiconducting compound, XLPE insulated, insulation screened with extruded semiconducting combination in combination with copper tape (0.3KA for 1sec.) cores laid up, FR PVC inner sheathed, galvanized steel strip armoured and overall FR PVC sheathed cable confirming to IS:7098 (Part-2), 2011 working voltage 11KV(E) grade to be laid 1.50 meter below ground level including excavation, sand cushioning, covering with sand & First class bricks and back filling the trench etc., of the required size:-
SPECIAL REPAIR/REPLACEMENT OF BER DG SET AND CONNECTED WORKS IN TECH AREA AT AF STN GWALIOR
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core complete all as specified and directed.