Loading…
Loading…
2,703 results • Best match
Supply, fixing, testing and commissioning of 2 nos. 100 TR with R134a Refrigerant water-cooled screw type chiller in place of existing 2 nos. 80TR water cooled reciprocating chiller in the 340 TR air conditioning plant in premises of Honble High Cour
Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F of MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting [F-1/2(b)]
REPAIR / MAINT OF STREET / SECURITY / HIGH MAST / GARDEN LIGHTS AND POST TOP LANTERNS AND REPAIR / MAINT OF DG SETS AT INS EKSILA UNDER AGE E/M NO-III OF GE(U-I) VISAKHAPATNAM
M&L for cutting the tarmac / hard standings in road and excavating trenches across the road in size not exceeding 0.45 m wide and 0.6 m depth for laying cable / cable protection pipe including refilling earth & making good top surface of the disturbed portion with 100mm thick PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) / bituminous mix as per existing & matching with the surroundings including removal of rabbish off to distance not exceeding 100 m complete all as specified and directed. Note:- Unit rate quoted against this item shall deemed to include cost of road cutting, earth work excavation, plain cement concrete work required for making good top of the surface, complete.
PROVN OF SEMIUNDERGROUND ALTERNATE ATC AND MET SECTION AT AF STN BKT
S&F PVC LED Batten lights fitting 1x 20W, 220V, colour Temperatur 6000 to 6500 K,PF>0.95,CRI>75,and THD10,230 volts AC 50Hz with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. JS&F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt PVC LED batten lights fitting 1x 20W, 220V, colour Temperatur 6000 to 6500 K,PF>0.95,CRI>75,and THD10,230 volts AC 50Hz with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. SS&F Ceiling Rose 65 x 50mm three terminals complete all as specified and directed. S&F Junction boxes (1 to 4 way) and fixing accessories such as lock nuts, saddles, etc.of size 32 mm all as specified and directed. S&F Rigid non-metallic PVC conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.of size 32 mm dia all as specified and directed. "gM&L for PCC type D-2 1:4:8 using 40mm graded stone aggregate in foundation, filling and mass concrete. _M&L for Reinforced concrete pipe 150mm bore class NP2 laid and jointed complete with collars. & dM&L for Rendering 15mm thick on fair faces of brick work or concrete surface in Cement Mortar 1:4. ÁM&L for PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate as in PCC coping, haunching, benching etc including slightly rounded or chamfered etc complete all as specified and as directed. wM&L for Cement concrete 1:2:4 type B-0 using 12.5mm aggregate in surface channel and drain complete all as specified. & ÂM&L for Forming fair finished drain or channel 80cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopped ends etc complete all as specified and as directed. # M&L for TMT bars 10mm dia and over, cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia all as specified and as directed. êM&L for Precast Cement Concrete 1:2:4 type B-1 using 20mm graded stone aggregates as in cover slab/MH cover with plain fair faces, including setting in cement mortar 1:4 complete with joints to match all as specified and as directed. . ¬M&L for Hardcore of gauge not exceeding 63mm using broken boulders depositted, spread and levelled in layers not exceeding 15cm thick watered and rammed to a true surface. , mM&L for PCC type C-2 1:3:6 using 40mm graded aggregate as in foundation of drains complete all as directed. wM&L for Brickwork with Fly Ash bricks, straight or curved in plan exceeding 6m mean radius built in Cement mortar 1:4. % M&L for PCC type C-1 1:3:6 using 20mm graded aggregate as in coping including weathering, slightly rounded or chamfered angles and throating as directed. M&L for PCC type B-0 1:2:4 using 12.5mm graded aggregate as in surface channels and drains complete all as specified and as directed. M&L for Forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopped ends etc. # £M&L for Rendering 10mm thick in Cement mortar 1:4 on brick surface and finishing plastered surface with using extra cement complete all as specified and directed. VM&L for Removing excavated material at a distance not exceeding 250m where directed. # wS&F 110mm bore dia PVC(SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors. ! qM&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in lean concrete in foundation all as specified. gM&L for RCC M-25 (using 20mm graded aggregates) design mix as in base of column/wall all as specified. oM&L for RCC M-25 (using 20mm graded aggregates) design mix as in walls, retaining walls etc all as specified. Use and waste of Formwork to sides of concrete foundation, footings, bases of columns and similar work, vertical or batter all as specified. . ÁUse and waste of Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar working including attached pilasters, buttresses etc vertical or to batter. + -All as per above item but 6 to 8mm dia bars. " úM&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping of columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia all as specified. " zM&L for 75mm bore PVC(SWR) pipe @ 2.50m c/c horizontal as in trenches or floors and 1.5m c/c vertical for weep holes etc. kSupply and laying Stone boulder of 63mm filling with each weep hole, hand packed tightly all as specified. ' M&L for Brickwork with subclass 'B' bricks, straight or curved in plan exceeding 6m mean radius built in Cement mortar 1:6 as in walls all as specified. * [M&L PCC 1:2:4 type B-0 using 12.50mm graded stone aggregate as in coping all as specified. cM&L for Rendering 15mm thick on fair faces of brickwork or concrete surfaces in Cement mortar 1:4. }M&L for Surface dressing not exceeding 15 cm deep and getting out in soft/loose soil complete all as specified and directed. ÊM&L for Removing excavated earth exceeding 1.5KM but not exceeding 5KM outside defence land and depositing at a level not exceeding 1.5m above the starting point complete all as specified and directed. ÇM&L for Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shafts, wells etc and not exceeding 1.5m in depth and getting out in soft/loose soil. mM&L for Exacavation over areas not exceeding 1.5m deep and getting out in soft/loose soil all as specified. vDitto as above but for Additional 1.5m or part thereof in depth beyond the first 1.5m as described in the above item. & þM&L for Excavation in trenches in any type of soil beyond 1.5m depth and not exceeding 1.5m width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes/pole foundation etc all as specified and directed. M&L for Removing excavated material not exceeding 250m and depositing where directed at a level not exceeding 1.5m above starting point. # ©M&L for Returning filling in soft/loose soil including spreading, levelling, watering & well ramming in layers not exceeding 25cm thick in each layers all as specified. ÆSupply and laying sand cushioning for cable protection in trenches 8cm before laying cable and 15cm deep over the cable including necessary watering and consolidation all as specified and directed. ! vM&L Construction of Septic Tank for 100 users including necess
SPECIAL REPAIR TO OR MD ACCN ADDL/ ALTN TO BLDG NO P 6 AND DHOLAPUR RED SAND STONE SARAGARHI AREA UNDER GE (WEST) FEROZEPUR
M&L for Sand cushioning using sand suitable for plaster works to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep punned to 10cm after laying and stretching the cable complete all as specified and directed. Note : 18 cm punned thickness shall be measured and paid.
8237/E8
Supply and laying DWC Cable duct/Pipe of outer dia of 40mm and inner dia of 39.3/37 mm polyethylene (PE) with smooth internal and profiled external surface for non pressure for undergound cable suitable for 25 sqmm to 16 sqmm cable including bend, connected coupler fittings for jointing etc complete all asspecified and directed by Engr in Charge.
Upgrading of Infrastructure and Facilities and other miscellaneous works at ALWR Office, BARC, Meghadri, Visakhapatnam, AP
Shifting and installation of 3KVA UPS from Conference room to outside corridor with laying of Incoming cable from DB to UPS and outgoing cable from UPS to Conference room 12way DB Box using DLP trunking and removing & refixing of all existing switchboards to designated location in wall panelling and cupboard work with required extension of wiring as per directed by EIC. i) SITC of 12way DB with cheaping and plastering as per directed by EIC. ii)SITC of 3 Core x 06 sqmm FRLSH felxible cable - 35 Meters iii)SITC of 3 Core x 04 sqmm FRLSH felxible cable - 65 Meters iv) SITC of 25 A, 10kA, type C Double Pole MCB - 02 Nos v) SITC of 25 A, 30 mA Double Pole RCCB - 01 Nos vi)SITC of 10A, 10kA, type-C Single pole MCB- 08Nos vii)SITC of 6 module switch boards with coverplate - 02 Nos. (along with 16/6 A socket - 04 Nos, 16A switch with indicator - 4 Nos) viii) SITC of 02 nos Primary power point wiring with 2.5 sq.mm. copper conductor from DB to Power point of average length of 30m using of PVC conelead conduit. ix) SITC of DLP trunking of 50 x 80 mm - 08 Mtr X) SITC of Industrial 32Amp industrial area socket with DP MCB of suitable rating along with mounting box and plug top with proper earting - 1No. xi) Supply and installation of 25mm Dia PVC conduit and necessary accessories like bends, junction boxes,etc. - 35Meter xii)Supply and installation of 25 x 12 mm casing capping- 15Meter xiii)Supply and installation flexible PVC conduit - 10Meter