Loading…
Loading…
2,661 results • Best match
SPL REP TO BLDG NO ET-393, ET-395, ET-286, ET-289 AND ET-331 AT CERTAIN UNIT IN CHANGSARI MIL STN UNDER GE RANGIA
M&L for Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as per specified and as directed by Engineer-in-charge. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be measured and paid for.
WELCOME MAINTENANCE OF OFFRS MD ACCN AND FAFA IN GARHI CANTT UNDER AGE B/R-I OF GE DEHRADUN.
Material and labour for laying, jointing and testing in replacement underground XLPE insulated & PVC sheathed, armoured heavy duty multistranded electric cable with aluminium conductor, 1100 volts grade in trenches/ ducts/ along poles/ through pipe/ under road/ PCC etc and connecting with new aluminium lugs including taking out existing unserviceable of any size/ type complete for the following cables of cross sectional area complete all as specified and directed: Notes: (a) Excavation, returning, removal, sand cushioning, cable protection covers, GI protection pipe etc shall be measured and paid separately. (b) Any damage done during cable excavation to the existing UG infra like UG pipelines, UG electric cables, OFC etc shall be repaired by the contractor at their own expenses. (c) Cost of T&P required for handling/ laying of cable is deemed to be included in the rate quoted by the contractor.
SPL REPAIR TO BLDG NO P-185, P-212 AND P-286 AT ANARWALA UNDER GE DEHRADUN
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out excavated soil/sand/unsv LT Cable for laying of cable and getting out in soft/loose soil complete all as specified and directed.
PROVN OF SINGLE OR LIVING WITH TOILET FACILITY AT 17 JAT AT SHILLONG FOR 16 ORS AND PROVN OF PATHWAY COVER SHED FROM GD POST OF SIGNAL COY TO CAFETARIA OF 17 JAT AT SHILLONG CANTT UNDER GE SHILLONG
Supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (Note : Punned thickness shall be measured).
GE/CHD/T-113/2025-26 PROVN OF GUARD ROOM WITH RECEPTION ROOM, GUARD ROOM WITH TOILET, TOILET, TOILET BLOCK AND COVERED SHED AT N AREA UNDER GE CHANDIGARH. .
Sand cushioning with clean dry sand to cables with layer of sand 8cm before laying of cable and 15cm thick after laying of cable complete all as specified. Note : For payment purpose punned thickness of 18cm shall be measured against spread thickness of 23cm as mentioned in para 19.75 of SSR part-I
COMPLETION OF IN COMPLETE WORK OF BALANCE WPRK FOR PROVN OF PREFAB SHELTER FOR LIVING IN ACCN FOR GE(P) AIR FORCE LEH AT AIR FORCE STATION LEH AT AIR FORCE STATION LEH
Material and labour, sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment.