Loading…
Loading…
2,771 results • Best match
As per tender docus
Supply laying & testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts, (Earthed), grade cross sectional area 6 sqmm, 2 core complete all as specified and directed.
REPAIR AND MAINTENANCE OF HT LINES, VCBs, RMUs, HT CONTROLING DEVICES ALONGWITH MISC ITEMS UNDER GE NAGROTA
Sand cushioning to under ground cable laid in trenches for laying of HT UG cable 8 cm depth before laying the cable and 15 Cm after laying and punned down to depth of 10 cm as per MES SSR Part -I (2009), complete all as specfied and directed.
PROVISION OF DEFICIENT PACKAGE TYPE STP 02 NOs OF CAPACITY 0.3 MLD AND 0.5 MLD INCLUDING SEWER NETWORK AT INS HAMLA, MUMBAI
Taking Down Existing LT UG armoured Cable by Manual Excavation without make and physical damage to Cable while excavation including taking Out LT cable covers and HDPE Protection Pipe for Rerouting The old cable all as directed by the Engineer-in-Charge for the following size of Cables. Note :The rate for Excavation, Extra LT UG Cables, Extra Cable covers and Extra HDPE pipes will paid and measured Seperately if required while old cable laying in Rerouting including all as specified and directed by the Engineer-in-Charge.
Rehabilitation of relay room,location box etc and strengthening of Axle Counter system over Sealdah Division.
"Excavation of trench at a of Depth of 1200 Kilometre mm. and width of 300 mm., including marking of cable alignment, clearing of jungle, roots of trees, bushes, refilling with excavated soil, ramming and consolidation after laying of cables complete to the finished item of work in all type of Soil. NOTE: In case 1.2 m. depth of the trench is n o t achievable d u e t o site conditions approval of officer in charge is to be obtained and payment shall be made on a prorate basis."
REPAIR/ REPLACEMENT OF BLDG SECURITY LIGHT, LIGHTENING CONDUCTOR, SOLAR OPERATED EQPTS AND REPAIR/ MAINT OF LT POWER CABLES, POLES AND EARTHING AND CONNECTED WORKS AT KASAULI UNDER GE KASAULI
Excavation in trenches n. exc 1.5 mtr in depth and not exc. 1.5 mtr in wide and getting out in soft/loose soil for laying of cables all as specified and directed.
PROVN OF ADDITIONAL TOILETS AT CERTAIN LOCATIONS AT AF STN PATIALA UNDER GE (AF) AMBALA
M&L for filling approved river sand in trenches for sand cushioning of laying of cables to the full width of excavated trench 08 cm thick before laying the cable and 15 cm above the cable, gently punned down, stretching and testing of cable on transformer yard etc complete all as specified and directed. Note :- Thickness of sand cushioning after punning down i.e 18 cm shall be measured for payment.