Loading…
Loading…
2,734 results • Best match
Replacement of existing 1st circuit Coyote ACSR conductor by HTLS (Equivalent to Drake ACSR) and stringing of 2nd circuit with HTLS conductor on exisitng DC towers of 66kV Anekal-Attibele line from 66/11KV Anekal sub-station to 66/11kV Attibele Sub-station for a distance of 6.545kms
Cables -Supplying and Laying
SPL REPAIRS TO BLDG NO P29 JCOS MD ACCN AT BIKRAM ENCLAVE AND OTHER SANCTION WORK UNDER GE SOUTH UDHAMPUR
Excavation in trenches in soft/loose soil not exceeding 1.5 M wide and not exceeding 1.5 Mtr deep and getting out including filling bottom surface to required level or slope for laying of pipes/ cables complete all as specified and directed by Engr-in-charge
SPL REPAIRS TO BLDG NO P11 OR MD ACCN AT BIKRAM ENCALVE UNDER GE SOUTH UDHAMPUR
Excavation in trenches in soft/loose soil not exceeding 1.5 M wide and not exceeding 1.5 Mtr deep and getting out including filling bottom surface to required level or slope for laying of pipes/ cables complete all as specified and directed by Engineer-in-Charge
Redevelopment of Sri Kaleshwara Muktheshwara Swamy Temple and Development works in and around the temple, Kaleshwaram (V), Mahadevpur (M), Jayashankar Bhupalpally District, Telangana.
MAIN POWER PANEL Supply, installation, testing and commissioning of floor mounting type panel board with Alluminium bus bars fabricated with 14/16 Gauge CRCA Sheet comprising of TPN bus bars of equal size in all phases and neutral equipped with bus bar chambers and cable chambers.The bus bars fault level shall be 50 KA and shall be as per the requirement of local CEIG, fire regulations, CPRI norms and other authorities etc. The painting of the complete system shall be powder coated duly processing the panel in 7 tank process. The panel shall be suitable for accomdating the following switch gear including supply of all components, hard wares etc including all necessary civil works, adequate reinforcement, foundation bolts, suitable G.I earth strip 40 x 6mm, door loop earthings, bus bars should be colour sleeved with heat shrinkable sleeves for phase and neutral duly supported at regular intervels by SMC supports and all cables shall have proper cable entry, danger board, feeder identification marks, rigid inter connections, cadmium plated bolts and nuts and shall be installed on flooring and consisting of the following as required and as per IS standards for [MAIN PANEL] Panel shall be manufacture only from CPRI approval Fabricators. 630A Alluminium Bus Bar with colour coded sleeves.(1.2A/Sqmm). Internal wiring with approved make cableEarthing Flat: Providing suitable G.I Flat INCOMING & ATS Supply of 630A 4 Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 35/36 KA with thermal magnetic release Panel Mounted.-2 Nos. Makes : Siemens / L&T / Schneider Supply and Fixing of fully enclosed 630A 4pole Automatic Transfer Switch (ATS) confirming to IEC 60947- 6-1 utilization cat AC 330 prewired with flexible settings and seemless transfer between two power sources. The enclosure made of powder coated of necesssary size. The switch comprising of Electricity Board / Diesel Generator priority Source selection, adjustable time delay 100ms, Ductable break contact system offering high short time withstand (ICW) with necessary terminal shrouds, phase barriers and source separators, protections of under voltage / over voltage, phase sequence, single Phrasing, frequency variation. There should be sufficient space for cable termination. Three phase, 415V capability to expand with RS 485 communication module, which ensures real time communication of data. Makes : Socomec / LK - 1No Supply and erection of 0-500V volt Digital meter of size 96x96mm on exisiting box / panel board including connections etc., complete.- 2 NosMAKES : CONZERVE / ELMEASURE / L&T / SEIMENS / HPL. Supply and erection of 0-400A Digital Ammeter of size 96x96mm on existing box / panel board including connections etc., complete. -2 Nos MAKES : CONZERVE / ELMEASURE / L&T / SEIMENS / HPL. Supply and erection of selector switch for Ammeter on the existing box / panel including connections etc., complete. - 2 Nos Makes : L&T / C&S / SALZAR / HPL MAKE. Supply and erection of selector switch for voltmeter on the existing box / panel including connections etc., complete. - 2 Nos Makes : L&T / C&S / SALZAR / HPL MAKE. Supply and erection of LED indication lamps on the existing panel board. - 6 Nos Makes : L&T / C&S / SALZAR / HPL MAKE. Supply and erection of LT current transformer with bar primary 800 / 5A ratio in the existing panel including connections etc., complete. - 6 Nos MAKE : KAPPA Supply of 250A 3 Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 36/35 KA with thermal magnetic release Panel Mounted.-4 Nos. Makes : L&T / Schneider / Siemens / Legrand / Hager. Supply of 125A 3 Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 25 KA with thermal magnetic release Panel Mounted.-4 Nos Makes : L&T / Schneider / Siemens / Legrand / Hager.
REPAIR/ MAINTENANCE OF TRANSFORMERS, VCBs PANELS, HT LINE AND HT PROTECTION SYSTEM AND CONNECTED WORKS AT BAKLOH CANTT UNDER AGE(I) DALHOUSIE.
Excavating in trenches in loose and hard/dense/disintegrated (in any type soil) n. exc 1.5 m wide ,depth exc. 1.5m for foundation, etc. or for laying/taking out cables etc.n exc 10 sq m on plan and getting out , all as specified.
Replacement of existing 2 X 5MVA by 2 X 8 MVA Power Transformer at 33/11 KV Sub-station Balekundri in Belagavi Taluk. Belagavi District on Total turnkey basis
B.14 Laying of Power cables from switchgears to DP of 11 kV cables in existing trench/G.I. pipe/stoneware pipe/RCC hume pipe using wooden/aluminium rollers as directed by KPTCL staff. 0