REPAIR MAINTENANCE AND REPLACEMENT OF UNSERVICEABLE EXTERNAL LIGHTING INSTALLATIONS INCLUDING STREET LIGHT, HIGH-MAST LIGHTS, GARDEN LIGHTS, JUNCTION BOXES, TIMERS, POLE PAINTING AND UNDERGROUND CABLING AT ASC MADGAON AND PONDA AREAS UNDER GE PANAJI
M&L for Checking/megering of UG cable fault of any size/core and taking out the damaged portion of cable from trenches and removing the fault portion of cable and checking, jointing the same with proper cable end jointing kit and testing for smooth functioning of complete cable and re-laying the same after testing of following size . Notes : (i) Excavation/earth work/returning filling/relaying of brick and relaying soft soil for cushioning deemed to including the job. (ii) Extra cable will be measured and paid under relevant item. iii) Joint kit required will be measured and paid separately under relevant item.
8808/E8- REPAIR / MAINT/ REPLACEMENT STREET LIGHTS, PERIMETER LIGHTS, GARDEN LIGHTS, DECORATIVE LIGHTS AND CONNECTED WORKS AT NTS TEYLERABAD, MARCOS, NAD/DAD/CHOULDHARI PUMP HOUSE, FILTRATION PLANT, INS UTKROSH, RUNWAY PERIPHERY AND VAYU VIHAR AND
Excavation in soft / loose soil not exceeding 1.5 mtr wide and n exc 1.5 mtr depth and getting out incl forming of bottom for laying cable all as specified and directed
20/EDCS/2026-27
Laying of XLPE Cable
26/SE(T)AMAUSI ZONE/2026-27
All Decentralized Items Provided/Fixing/ Erection/Installation/Laying/Foundation with earthing by the contractor as on his own cost as per RESPO Narms. 33 KV LINE ERECTION WORK Minimum depth of laying from ground surface to the top of cable as per IS is 1)Low Voltage (1.1KV) and control cable 0.75 Mtr 2) 3.3 KV to 11 KV Cables 0.90 Mtr 3) 22 KV to 33 KV Cable 1.05 Mtr 4) Cables at Road Crossing 1.00 Mtr 5) Cable at Railway Laval Crossing ( measured from bottom 1.00 Mtr Of sleepers to top of pipe) Note- 1- The depth may be increased but not more than 1.6 Mtr 2- The Standard depth and width for laying the cable are also attached ( as per letter No 561/Director(Tech)/MVVNL/Camp/Dt 09.01.2026 with the tender form)
PROVN OF 16 X SOLAR LED STREET LIGHT WITH POLE AND ACCESSORIES IN OTM AT AGARTALA MILITARY STATION
Excavation in trenches not exceeding 1.5 m width or n exc 10 sqm on plan and n.exe 1.5 m in depth for taking out/laying of cable,foundation etc and getting out in soft/loose soil complete all as specified and as directed.
Rate Contract for Supply Installation Commissioning of CCTV Surveillance Cameras
283 CI – INSTALLATION 26CI5 Fibre Cable Laying (A): Laying & fixing of Outdoor Armored Fiber Cable without HD & GI Steel pipe.- Underground. • Fibre Cable Laying (A): Laying & fixing of Outdoor Armored Fiber Cable without HD & GI Steel pipe.- Underground.