CONSTRUCTION OF NEW 33by11 KV (2X5 MVA) SS SONIK II AT DISTT UNNAO
Laying & dressing of 11KV 3x300 Sq.mm XLPE cable from 5MVA T/F to 11KV incoming Switchgear by excavation of trench in the ground of size 450mm wide, 900mm deep providing 150mm fine sand cushion below the cable. The cable shall be duly protected by bricks, sand & stone slab and refilling & ramming of the left out soil. Spare cable shall be left and buried in the trench in the shape of rings at both ends. Cable laying work includes unrolling, cutting, making ring and sealing both ends of the cable. (All decentralized/consumable materials to be provided by Contractor).
Electrical work in connection with provision of Power supply arrangement for New mechanized Laundary at ASH & GTNR, power supply arrangement work for SETC of PERC Dry cleaning machine , SETC of Tumbler Dryer , SETC of Rotary screw electric driven Air compressor , SETC of washer extractor , SETC of folder machine with stacker and SITC of feeder machine at linen center at GKP.
Laying of 1 No. XLPE insulated and PVC sheathed power cable of grade 1.1 KV size 3½/4 core size exceeding 25 sq mm but not exceeding 400/120 Sq mm Alluminium conductor cable direct in ground including excavation, sand cushioning, protective covering and refilling the trench 10 etc. as required. Cable laying should be as per IS-1255/1983 with latest ammendments. Digging of trench in all kinds of soil up to the depth of 1000 mm and 350 mm wide for laying of cable with supply and placing of second-class bricks, approx. 10 bricks per meter, refilling of cable trench with solid earth consolidating by ramming by 270 mm above the surrounding level over trench. (Cable will be supplied by Railway)
SPECIAL REPAIR TO JCOs/OR MD ACCN BUILDING NO P-860 AT S S COLONY AT BB CANTT, SRINAGAR.
Supply, laying and testing of LT cable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 volt grade cross sectional area of size 35 sqmm 3.5 core including laid in trenches or fixing on poles or passing through pipes complete including taking out of old unserviceable cable any type any size And including Excavation of cable trench, laying of underground cable with sand cushioning, protection cover, refilling and compaction complete all as specified and directed.
Establishment of Electrical Installation work for Fire Pump and X-ray Machine at Tufanganj SD Hospital, Tufanganj, Cooch Behar.
Laying of one No. cable in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed
Electrical work in connection with Provision of Ramp for FOB under Harmonized guideline for Divyangjan Facilities at 54 stations (Total 108 Ramps) and Improvement of sub-station building in different Sub-Station over LJN- DIV.
Laying of 1 No. XLPE insulated and PVC sheathed power cable of grade 1.1 KV size 3½/4 core size exceeding 25 sq mm but not exceeding 400/120 Sq mm Alluminium conductor cable direct in ground including excavation, sand cushioning, protective covering and refilling the trench 31 etc. as required. Cable laying should be as per IS-1255/1983 with latest ammendments. Digging of trench in all kinds of soil up to the depth of 1000 mm and 350 mm wide for laying of cable with supply and placing of second-class bricks, approx. 10 bricks per meter, refilling of cable trench with solid earth consolidating by ramming by 270 mm above the surrounding level over trench. (Cable will be supplied by Railway)
INCREASING CAPACITY OF 33by11 KV SS BARGANWA (FROM 2X5TO 3X5 MVA) and 33by11KV SS HUSAINGANJ RURAL (FROM 2X10TO 2X10plus1X5 MVA) AT DISTT SITAPUR
Laying & dressing of 11KV 3x300 Sq.mm U/G cable Double Ckt. from 5MVA T/F to 11KV incoming Switchgear by excavation of earth in the trench 450mm wide, 900mm deep providing 150mm fine sand cushion below the cable. The cable shall be duly protected by bricks, sand & stone slab and refilling & ramming of the left out soil. Spare cable shall be left and buried in the trench in the shape of rings at both ends. Cable laying work includes unrolling, cutting, making ring and sealing both ends of the cable.(All decentralized/consumable materials to be provided by Contractor).