10,860 results • Best match
REPAIR/MAINT OF SECURITY / STREET / FLOOD LIFGT FITTING AND STREET LIGHT CONTROL PANEL AND ALLIED WORKS AT BEG AND CENTRE UNDER AGE E/M-I AT GE(C) KHADKI.
Material and labour for earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 3 mtr long buried... drilling rig (for drilling near the specified location), connected with galvanised steel earthing lead of 25x4 mm all as shown in Plate No-2, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2 with pit cover, funnel, wiremesh, 32 mm ...
HIRING OF EPMC FOR ENGINEERING, DESIGN AND PROCUREMENT SERVICES FOR KAMRUP AND KAMRUP METROPOLITAN GA AND CACHAR, HAILAKANDI AND KARIMGANJ GA FOR A PERIOD OF 2 YEARS
Design & Engineering for development of Steel Pipeline network for CGD including Underground pipeline, above ground piping, SV Stations, CP systems, branch / spur pipeline connections to DRS/ MRS/ CNG stations / Consumer terminals including Instrumentation / electrical / Civil works for completion of the Steel pipeline network in all respect
Construction Of School Building at PS Gulabbagh(S.No 279)
... Havell/Polycab/Anchor/eq,standard make as desired by engineer incharge ) single core cable in surface/recessed medium class PVC conduit, with modular switch (Anchor ramn plus/... plus/ Legand Mylinc /SSK NV/Schnelder/ABB Tvisho make) moduar plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.as approved by EIC.
Construction Of School Building (Dilapidated) at GMS Lethpora (S.No 272)
... Havell/Polycab/Anchor/eq,standard make as desired by engineer incharge ) single core cable in surface/recessed medium class PVC conduit, with modular switch (Anchor ramn plus/... plus/ Legand Mylinc /SSK NV/Schnelder/ABB Tvisho make) moduar plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.as approved by EIC.
CA NO GE(N)AMB-22/2026-27 SPECIAL REPAIR OF BLDG NO P-318 OF SINGLE OFFR ACCN OF MED REGT UNDER AGE B/R-II OF GE (NORTH) AMBALA CANTT
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 4.0 core, complete all as specified and as directed. (Note :- excavation & earth work shall be measured & paid separately under respective items of B/R portion )
REDEVELOPMENT OF BATASHIDHEPA WATERBODY
Providing, supplying, installing, testing and commissioning the complete MEP system for an artificial water cascade, including... pressure-rated delivery pipelines with valves, unions, strainers and flow-control arrangements, electrical cabling from panel to pump with weatherproof conduits, earthing, pump starter panel with MCB/MCCB, contactors, protection relays and auto–manual control, ...