Loading…
Loading…
11,006 results • Best match
PETTY REPAIRS AND CERTAIN B/R WORKS IN RV, SV and HV AREA INCLUDING ELECTRICAL FITTINGS / FIXTURES, MODULAR ACCESSORRIES AT AF STN PALAM UNDER GE (AF) PALAM DELHI CANTT-10
S&F mild steel work in framed work such as grills, gratings, ladders etc., with ends of bars shouldered and/ or riveted, or forged into spikes, and similar work conforming to Fe 410 -0 or Fe 310 -0 complete all as specified and as directed.
Comprehensive Maintenance Works(excluding Bridges) of all Civil, Electrical & S&T Building including Station Buildings, Technical Buildings, Residential Quarters and Utility Service Buildings under the jurisdiction of CGM/DDU Unit.
4.3.1 Foundations, footings, bases for columns Total 313720.00 5.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts Item- 8 etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement S No. Item No Description of Item Unit Qty Rate Amount 1 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 cum 50.00 10852.95 542647.50 graded stone aggregate 20 mm nominal size) Total 542647.50 Item- 9 5.9: Centering and shuttering including strutting, propping etc. and removal of form for : S No. Item No Description of Item Unit Qty Rate Amount 1 5.9.1 Foundations, footings, bases of columns, etc. Sqm 500.00 307.95 153975.00 for mass concrete. 2 5.9.2 Walls (any thickness) including attached Sqm 500.00 669.55 334775.00 pilasters, butteresses, plinth and string courses etc 3 5.9.5 Lintels, beams, plinth beams, girders, Sqm 600.00 608.35 365010.00 bressumers and cantilevers 4 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Sqm 400.00 804.25 321700.00 Struts Total 1175460.00 5.22: Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in Item- 10 position and binding all complete upto plinth level. S No. Item No Description of Item Unit Qty Rate Amount 1 5.22.6 Thermo-Mechanically Treated bars of grade Fe- Kg 1500.00 107.85 161775.00 500D or more. Total 161775.00 5.22A: Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in Item- 11 position and binding all complete above plinth level. S No. Item No Description of Item Unit Qty Rate Amount 1 5.22A.6 Thermo-Mechanically Treated bars of grade Fe- Kg 1000.00 107.85 107850.00 500D or more. Total 107850.00 6.2: Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and Item- 12 plinth in: S No. Item No Description of Item Unit Qty Rate Amount 1 6.2.1 Cement mortar 1:4 (1 cement : 4 coarse sand) cum 200.00 6504.90 1300980.00 Total 1300980.00 10.16: Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., Item- 13 including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. S No. Item No Description of Item Unit Qty Rate Amount 1 10.16.1 Hot finished welded type tubes Kg 2500.00 194.40 486000.00 Total 486000.00 10.25: Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in Item- 14 position and applying a priming coat of approved steel primer using structural steel etc. as required. S No. Item No Description of Item Unit Qty Rate Amount 1 10.25.2 In gratings, frames, guard bar, ladder, railings, Kg 1500.00 172.60 258900.00 brackets, gates and similar works Total 258900.00 11.26: "Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey Item- 15 cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :" S No. Item No Description of Item Unit Qty Rate Amount 1 11.26.1 25 mm thick Sqm 250.00 1948.25 487062.50 Total 487062.50 EDFC FIELD UNIT-DDU-CIVIL/EDFC 11.41: Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved Item- 18 make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand),jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. S No. Item No Description of Item Unit Qty Rate Amount 1 11.41.2 Size of Tile 600x600 mm Sqm 200.00 1553.45 310690.00 Total 310690.00 Item- 19 13.1: 12 mm cement plaster of mix : S No. Item No Description of Item Unit Qty Rate Amount 1 13.1.1 1:4 (1 cement: 4 fine sand) Sqm 1200.00 347.05 416460.00 Total 416460.00 Item- 20 13.7: 12 mm cement plaster finished with a floating coat of neat cement of mix S No. Item No Description of Item Unit Qty Rate Amount 1 13.7.2 1:4 (1 cement: 4 fine sand) Sqm 500.00 425.55 212775.00 Total 212775.00 13.41: Distempering with oil bound washable distemper of approved brand and manufacture to Item- 21 give an even shade : S No. Item No Description of Item Unit Qty Rate Amount 1 13.41.1 New work (two or more coats) over and Sqm 1100.00 185.65 204215.00 including water thinnable priming coat with cementprimer Total 204215.00 Item- 24 13.85: Applying priming coats with manufacture, having low VOC ( mixed (hard and soft grams/litre S No. Item No Description of Item Unit Qty Rate Amount 1 13.85.3 W i t h water thinnable cement primer o n wall Sqm 5000.00 73.95 369750.00 s u r f a c e h a v i n g VOC content l e s s than 50grams/litre Total 369750.00 Item- 26 13.100: Painting with aluminium paint of approved brand and manufacture to give an even shade: S No. Item No Description of Item Unit Qty Rate Amount 1 13.100.1 One or more coats on old work Sqm 2000.00 96.00 192000.00 Total 192000.00 Item- 27 13.111: Finishing walls with Acrylic Smooth exterior paint of required shade: S No. Item No Description of Item Unit Qty Rate Amount 1 13.111.1 Old work (Two or more coat applied @ 1.67 ltr/ Sqm 5000.00 120.75 603750.00 10 sqm) on existing cement paint surface Total 603750.00 14.1: Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the Item- 28 surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge S No. Item No Description of Item Unit Qty Rate Amount 1 14.1.1 With cement mortar 1:4 (1 cement : 4 fine Sqm 500.00 547.40 273700.00 sand) Total 273700.00 14.5: Renewing glass panes, with putty and nails wherever necessary including racking out the old Item- 29 putty: S No. Item No Description of Item Unit Qty Rate Amount 1 14.5.1 Float glass panes of nominal thickness 4 mm Sqm 100.00 1090.65 109065.00 (weight not less than 10kg/sqm) Total 109065.00 26.35: Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/ masonry by suitable gun/pump at required pressure including Item- 34 cutting of nipples after curing etc. complete as per directions of Engineer- in-Charge. (The payment shall be made on the basis of actual weight of approved grout injected.) S No. Item No Description of Item Unit Qty Rate Amount 1 26.35.3 Epoxy injection grout in concrete/RCC work of Kg 500.00 553.40 276700.00 approved make Total 276700.00 EDFC FIELD UNIT-DDU-CIVIL/EDFC 26.30: power driven drill machine to a minimum depth of 100mm upto 200mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel Item- 35 bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In- Charge. S No. Item No Description of Item Unit Qty Rate Amount 1 26.30.1 Upto and including 12mm dia. Each 200.00 141.20 28240.00 Total 28240.00
Hubballi Division: BAY - RDG section: Provision of Two additional loop lines with R&D facilities along with associated Civil, Track, Signal, TRD and Electrical (Genl) works at Obulapuram station (Phase II) (Composite tender).
of (50/100/150mm dia) for cable laying with offset at both ends and with couplings over RCC Bridges/ Drainage/ Culverts with concrete masonry supports of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes shall be closed with brick masonry abutments work so that no cable is exposed, the work shall be carried out as per the instructions of Railway representative at site. (Supply of GI pipes with couplings and laying of cables is not included in this item). [Stone jelly of size 20/25mm, bricks, sand, cement and all other miscellaneous materials required for the work shall be supplied by the Contractor].
Supply, delivery and fixing of MS Kiosk Box , Wooden Board and Other electrical work for Mini Power Pump in West Tambaram Area Ward No.33,49,50,51Zone No.4 TCMC
Earthing as per PWD standard with an earth electrode of 2 metre Class 'B' GI pipe of dia not less than 32 mm complete with necessary masonry work
Repaires to roof, compound wall (Length 114m , height 1.50m, fixing of gates,plumbing work & electrical work at devarabhupur sub center under PHC Gurugunta in lingasugur Taluka of Raichur (Under ZP Link Doccument (Health department Grant) for the Year 2026-27) (RESERVED FOR CAT-II A)
Repaires to roof, compound wall (Length 114m , height 1.50m, fixing of gates,plumbing work & electrical work at devarabhupur sub center under PHC Gurugunta in lingasugur Taluka of Raichur (Under ZP Link Doccument (Health department Grant) for the Year 2026-27)
Upkeeping of entire Right of Way (ROW) excluding main carriageway of various Street Scaped Road comes under South Zone, PWD, New Delhi. (SH Civil and Electrical Work).
Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver asper the requirement with Driver efficiency >85%,Input voltage: 140-270 Volt AC, frequency 50/60 hz Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD 10% as per IEC61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70,under voltage and over voltage protection, EMIEMCAs per CISPR -15, lenses for beam angle asper IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) 5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).