Loading…
Loading…
10,796 results • Best match
Replacing damaged converters.
Construction of Laboratory and Building at Govt. Kirodimal PG College, Raigarh. i/c W.S.S.F. Electrification, Boundary wall & Approach Road Works.
S/L of 6core armoured/outdoor optical fiber cable generally confirming to EIA/TIA 568-C.2 and IEC/ISO11801 Excellent margin with suppression of cross talk 4 pair separator design 23 AWG cable for outdoor installation with laying cable underground with suitable size pvc conduit/casing capping and other accessories as per requirement
REPAIR/MAINT OF INTERNAL ELECTRIFICATION AND CONNECTED WORKS AT HQ CIF (R ) UNDER AGE (I) CIF (R)
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire
Custom Bid for Services - Laying, jointing and dismantling of MS pipe line 6/150mm & 8/200mm diameter 1500mtr and 3500mtr and dismantling, shifting & installation of pump motor set with electrical and accessories for 4/5 & 6/7 mines of Rajgamar S.. Similar Category Piping Erection Service
shifting & installation of pump motor set with electrical and accessories for 4/5 & 6/7 mines of Rajgamar S.. Similar Category Piping Erection Service
CONSTRUCTION OF FIRE STATION BUILDING OF 2 UNIT FIRE STATION AT DUMROA IN THE DISTRICT OF BUXAR - WITH ELECTRIFICATION
Electrical work
Electrification work of record room, meeting hall and toilet on the first floor of Assistant Divisional Transport Office, Lalitpur.
LED Batten light (System lumen efficacy ≥120 135 lm/Watt) Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard DeviationColour Matching) 3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen lumen efficacy ≥120 135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm). 40 Watt