Loading…
Loading…
10,901 results • Best match
Construction of Higher Secondary School Rajpur Block Rajpur Distt Balrampur Ramanujganj (C.G.) including Electrification Work.
Annual Repair and Maintenance of Internal Electrification work at JNKVV, Jabalpur (F. Year-2026-27)
Annual Repair and Maintanance of Internal Electrification works at JNKVV, Jabalpur (for F.Y. 2026-27)
REPAIR/MAINT OF INTERNAL ELECTRIFICATION AND ALLIED WORKS IN OTM ACCN AT KATAPAHAR UNDER AGE I DARJEELING
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (light grade) and chamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 1991 with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs) including taking down old unserviceable one, complete all as specified & testing on completion. NOTE:- (I) item includes the cost of 7.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr earth lead GI earth wire. (iii) PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
Construction work for new proposed 3311 KV SS Partapur and Erection of 33 KV line 11 KV IC under Assistant Engineer HTM Behror under TN- 188 on ARC 2025 in the Jurisdiction of Kotputli of Jaipur Discom
3 Nos. of earthing of 11/0.4 KV distribution transformer /sub-station with 3 pieces of M.S.Rod 20mm dia each 3 meter long and driving them into earth by mechanical means at a distance as per approved design & drawing & specification.The work includes flattening of top ends of M.S.rod drilling a hole of 9/16" dia.at flattened top and tightening of M.S.flat 50x6mm/25x3mm (having 3 hole 2ends and 1mm middle) with nuts and bolts with M.S.rods top end hole.The flat will also be welded with M.S.rod.The end will be connected to equipments as under in sequence. (1 Per earthing)
CONSTRUCTION OF FIRE STATION BUILDING (G+3) OF 02 UNIT FIRE STATION AT KAHALGAON IN THE DISTRICT OF BHAGALPUR WITH ELECTRIFICATION
Electrical work
Design, Supply, Installation, Testing, and Commissioning of a Sewage Pumping Station, Sewerage Treatment Plant (open technology) of 250 MLD Capacity, including Piping, Mechanical, Electrical, and Instrumentation Components, complete with Operation and Maintenance for up to Ten Years at Vinzol in Hathijan Ward of East Zone in AMC Ahmedabad Municipal Corporation.