Loading…
Loading…
10,816 results • Best match
REPAIRS REPLACEMENT OF INTERNAL ELECTRIFICATION INCLUDING FITTINGS AND FIXTURES AT ZONE C AREA UNDER AGE EM (N) OF GE (NORTH) SECUNDERABAD
M&L Earthing with galvanized mild steel earth plate electrode 60 centimetre x 60 centimetre x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below ground level, the top edge of the earth plate at a depth of not less than 1.5 metres below ground level connected to galvanized iron earth wire of 4 mm dia by means of bolts, nuts and washers made out of GI / steel earth wire protected by GI light grade pipe 15 mm bore, 20mm dia light grade galvanised iron pipe with funnel wire mesh for watering and connecting to main switch board / control board all s shown in electrical plate of SSR Pt - I connected to earthing test point and including testing on completion complete all as specified and as directed. Note: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 type C1 by using 20 mm graded aggregate in pit, 50 mm thick reinforced cement concrete 1:2:4 type B1 using 20 mm graded aggregate cover duly reinforced with 8 mm dia TMT bars @ 100mm centre to centre both ways, CI cover with CI frame hinges, galvanised iron funnel with watering pipe, wire mesh, complete.
Construction of Indoor shooting Range CISR of 50 m x 8 lanes for 27 SCG NSG at regional Hub Chennai-12 i/c Internal water supply and sanitary installation and also providing internal electrical installation UPS power wiring telephone conduits ... panels cabling etc ...
REPAIR AND MAINTENANCE AND IMPROVEMENT OF HT OH LINES AND CABLES, SWITCH GEAR, PROTECTION SYSTEM, CALIBRATION OF RELAYS AND OTHER CONNECTED WORK AT ELECTRIC INSTALLATION DALHOUSIE UNDER AGE(I) DALHOUSIE CANTT.
M&L for Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cms thick, complete all as specified and directed Note: Punned thickness shall be measured.
REPAIR MAINT OF INTERNAL ELECTRIFICATION OF CERTAIN OTM AND MD ACCN AND ITS CONNECTED ITEMS OF ZONE B UNDER GE ARMY DHAR ROAD
Supply and laying dry river sand to be laid in 8 cms before laying of cable and 15 cms above cable in trenche as cable cushioning and covering complete all as specified and as directed. Note: for payment purpose punned thickness shall be measured.
Corporate Tower (Phase-01) of 2nd & 3rd floor Interior work & Electrification work at Udyog Bhawan, Raipur, (C.G.).
Providing Internal Electrification of Boys Hostel Building in Govt. Tribal Ashram School Complex at, Sawane Tal.Talasari, Dist.Palghar
Providing Internal Electrification of Boys Hostel Building (G+3) in Govt. Tribal Ashram School Complex at, Sawane Tal.Talasari, Dist.Palghar