SPECIAL REPAIR REPLACEMENT OF WATER SUPPLY DISTRIBUTION SYSTEM STARTER AND OTHER CONNECTED WORKS OLD VINTAGE ALUMINIUM WIRING INTO COPPER WIRING WITH CONNECTED FITTING FIXTURE AT KALANAGAR SURAKAHA ENCLAVE AND DSC BILLETS ELECTRIC POLE STREET LIGHT
Material and labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983, complete all as specified and directed. Note :- (i) Excavated approved soil shall be ribbed by using sieve to separate composite particles etc. as per IS and refilling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is then gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness shall be considered for payment.
REPAIR REPLACEMENT AND DAY TO DAY MAINTENANCE OF ELECTRIC FITTINGS FIXTURES INCLUDING HEATING COOLING APPLIANCES AND OTHER ALLIED WORKS AT OTM MARRIED ACCN AT DIAT GIRINAGAR PUNE 25
Supply, Laying, and testing cable XLPE insulated screened PVC bedded, galvanized steel strip armored, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 x 4 core including connecting the cables at both ends by providing suitable size aluminium lugs at the termination ends complete all as specified and directed.
Repair maint of DG Sets, AMF panels, earthings and certain EM eqpts and plants including misc EM repairs to installations at AF station jodhpur under 32 Wing and Repair replacement of street light fitting security light fitting, high mast flood lig
supply and laying of Local tibba dry sand cushioning and cover (8 cm thick layer of sand before laying of cable and 15 cm thick layer of sand after laying of cable) for protection of cable, material and labour complete all as specified and as directed by Engineer-in-Charge.
SCR Construction Organization: Engineering, Procurement and Construction (EPC) contract for "New Bypass line between Yerpedu and Pudi Stations with Signalling & Telecommunication, Electrification works including augmentation of existing 1X25kv TSS/SP/SSP to suit proposed line in Guntakal division in the State of Andhra Pradesh.
NON SOR ITEM: Modifications to existing SCADA 3 3a Erection of Traction masts, Feeder Masts, AT mastsand Main MT 10.00 3465.00 34650.00 Masts of switching stations 4 7a Erection/Stringing of Along Feeder (either All Aluminium 25 kV Kilometre 1.50 12004.00 18006.00 Feeder (single spider) or Copper Feeder wire) 5 3b Erection of TTCs, portals and small parts steel MT 2.00 3465.00 6930.00 6 3e Supply and erection of Guy Rod Assembly Each 12.00 10451.00 125412.00 7 1(b) Preparation of Design & Drawings for Switching Station (SP/SSP) Each 2.00 40828.00 81656.00 8 1(e) 1e Preparation of Design & Drawings for Traction substation Each 1.00 88273.00 88273.00 9 2(b) Concrete for foundation other than hard soil and rock. cum 100.00 9230.00 923000.00 10 11(b) Supply (without Insulator) and Erection of 25 kV Post Insulator Each 20.00 1186.00 23720.00 11 13(g) Supply (without Insulator) and Erection of 25 kV Double Pole Each 6.00 5340.00 32040.00 Isolator (1600A)without earth contact assembly 12 15(c) 15c Supply & Erection of 160 sq.mm Large Copper Jumper Each 18.00 5620.00 101160.00 between Aluminium Bus and Cross feeder 13 15(d) Supply & Erection of 160 sq.mm Large Copper Jumper between Each 18.00 3957.00 71226.00 Cross feeder and OHE 14 15(e) Supply & Erection of Aluminium Jumper Each 18.00 3996.00 71928.00 15 17(d) Supply and Erection of Copper Strips (25x3 mm) for Equipment Metre 15.00 1044.00 15660.00 earthing 16 18(a) Erection of 25 kV Vaccum Interruptor (BM) Each 5.00 5596.00 27980.00 17 19(a) Erection of 25 kV Type-II Potential Transformer (PT) Each 3.00 1340.00 4020.00 18 20(a) Erection of 42 kV Lightning Arrester Each 5.00 847.00 4235.00 19 3(as) Supply of Rolled or Fabricated and Galvanized traction masts, MT 5.00 132174.00 660870.00 switching station maasts, AT masts, feeder masts etc. 20 3[cs] Supply of Fabricated and Galvanized Small Parts Steel (SPS) MT 2.00 147256.00 294512.00 other than Masts, TTCs and Portals. 21 7(as) Supply of All aluminium 25 kV feeder conductor (Single Kilometre 1.50 229628.00 344442.00 spider19/3.99mm) 22 7(bs) Supply of 150 sq.mm hard drawn stranded copper cross feeder Kg 80.00 1350.00 108000.00 wire 23 11a(i) Supply (without Insulator) and Erection of 25 kV Solid Core cut-in Each 20.00 2570.00 51400.00 insulator 24 17(c ) Supply and Erection of Single Earth electrode at TSS/SP/SSP/AT Each 12.00 6047.00 72564.00
REPAIR/ REPLACEMENT AND MAINTENANCE OF BUILDING PANELS ALONGWITH ALLIED WORKS AND REPAIR/ REPLACEMENT AND MAINTENANCE OF STORAGE TYPE WATER HEATERS, CEILING FANS, WALL FANS, EXHAUST FANS AND ELECTRIC METERS UNDER GE (AWC) MHOW
Supply and laying unreinforced PCC Cable protection cover, class LV, type-1 flat with size 250 x 150 x 40 mm laid flat width wise complete all as specified and directed.
REPAIR REPLACEMENT OF INTERNAL ELECTRIFICATION SERVICE SUBMAIN WIRING DB MCB LED LIGHT FITTING AND ALLIED WORK INCL WELCOME MAINT EM SERVICES AT HQ CAC HAPPY HOMES MES CIVILIAN MD ACCN MD ACCN AT NORTH CAMP AREA AND ALLIED AREA AT AF STN BAMRAULI
Earthing complete with Galvanised steel earth plate electrode 600 x 600 x 6 mm buried directly in the ground vertically to depth not less than 3 Mtr below the ground level with the top edge of earth plate, depth not less than 2.25 Mtr below the ground level connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts and washers protected by GI tubing light grade 40 mm dia uptoTest point 20 mm dia watering pipe with funel & wire mesh, PCC pit in PCC 1:2:4 using 20 mm stone aggregates chamber 40 mm thick RCC cover slab (1:2:4) type B-1 using 20 mm graded stone aggregates complete all as specified and shown in electrical plate No.3 of SSR Part-I including earth work in any type of soil ,removal of surplus sil and providing charcol dust & salt layers all around the earth plate upto 15 cm all as required, complete specified & directed by engr in charge. ( Note:- Up to 7.5 Mtr length of pipe of 40 mm dia and GI strip shall be deemed to be included in unit rate quoted by tenderer GI pipe and GI strip beyond 7.5) will be measured separately under respective item.