Loading…
Loading…
10,791 results • Best match
As refer boq
Providing and fitting concealed internal Electrification of room including 4 Nos LED lights, Fan points 2 No., Fuse box 1 No., 2 no 15 Amp sockets with switch, 5 Amp 2 no. sockets with switch - of approved brand and 04 nos LED security lights 30 watts, Main switch with complete wiring, with MS bracket for pole mounting complete including service line up to a length of 10 meters.
REPAIR MAINT OF DG SETS DG SET PANEL EM EQPT AC REFRIGERATOR AND ALLIED WORKS AT PEDONG ALGARAH AP ALGARAH DALAPCHAND TEESTA TCP RHENOCK AND RONGLI UNDER GE 867 EWS
Supply and Laying XLPE cable size of size of 95 Sqmm 3.5 Core Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor laid in trench/ on wall with the help of shadel including suitable cable lugs and electric connections all as specified at site.
Repair And Renovation of Existing SE (Project) Office Building Sawai Madhopur
... and 50 cm beyond 114.3mm outer dia around the pole. Duly finished with cement plaster, earthing terminals, cable entry with 32 mm dia. 'B' class GI cable sleeves complete as required. of following height & designation. ( See Table P - 02 for... pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Construction of Multipurpose Stadium at Dobal in Dhamnagar Block in the District of Bhadrak for 2025-26.
Installation of Submerssible pump set in the Bore-Well. Supply, Installation, testing & commissioning of 3-phase, 50Hz Submersible pump set of required head 100 mtr... Tube-well cover and cap suitable for above Pump-set and Suitable size of Four core flat cable of 120 mtr with Bore bunched copper conductor insulated sheathed with PVC for Submersible ...
Vertical extension for the Maternity ward of Durgapur S.D. Hospital,Paschim Bardhaman.
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish. Above 35 sqmm to 95 sqmm at an average depth of 100 mm in floor/pavement/wall etc. (i) 4 Core 50 Sq. mm
SPL REP TO BLDG NO ET-62 AND ET-67 AT DARRANGA MIL STN UNDER GE RANGIA
M&L for Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, ...