Loading…
Loading…
60,532 results • Best match
GENERAL-Balance works for the completion of Govt. Vocational Higher Secondary school, Malayinkeezhu (Providing new Auditorium and Theater) in Kattakkada LAC-Providing EI-General Electrical Work
90.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
Upgradation/Renovation Works in the Office of Commissioner of Excise, Entt. and Luxury Tax, L and N Block, Vikas Bhawan, IP Estate, New Delhi (SH - Electrical Work
LED Panel light 2x2 ft. (System lumen efficacy =105 120 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5°C to 40°C, internal surge protection of 2. 5 KV with Short & Open circuit protection, THD 10%, P. F. =0. 95, IP20, CRI >80, UGR (Unified Glare Rating) 19, Flicker free, (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) 3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1. 5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =105 120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness > 0. 50 mm) (a) 36 watt
Improvement of internal lighting by replacing existing old fittings with LED well-glass luminaires, MS panelling for switchboards inside godowns, repair of non-functional high mast tower lights and other allied electrical works
LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy≥105 120 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI- EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) 5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
GENERAL-Providing fire extinguishers in Mini Civil Station Aranmula -Supply and installation of fire extinguishers-Electrical Fire Fighting Work
Work Name:GENERAL-Providing fire extinguishers in Mini Civil Station, Aranmula -Supply and installation of fire extinguishers-Electrical Fire Fighting Work
Supply, Installation, Testing , Commissioning of illumination system including allied electrical installation works on Sidhu- Kanho- Birsha Setu at Gopiballavpur, in the district of Jhargram
Interconnection :- All interconnection between incoming main to Busbar are to be made with suitable size 99.9% – 99.5% electrolytic tinned copper bars or equivalent flexible pvc insulated multistranded single cor Cu cable and the same between busbar to all outgoing mains and also for metering arrangements are to be made by suitable size of Copper wire with proper socketing of the end of each wire leads. Earthing Arrangement :- A separate continuous aluminum earth busbar of appropriate size is to be painted at the inside bottom of the panel and run across the full load of the Feeder Pillar Box. All electrical equipment are to be properly earthed with suitable size G.I. strip. The complete Feeder Pillar Box is to be spray painted after required surface treatment by 7 tanks process / sand blasting with 2 coat of red oxide primer & 2 coat of finished paint over dried or powder coating. Installation :- The complete feeder pillar box board is to be installed on suitable brick padestal as directed by the E.I.C.
Electrical installation with maintenance works of the mech. and traffic section in the Terminus-Cum-depot of SBSTC at Digha Dist. Purba Medinipur.
eProcurement System of Government of West Bengal Created By: PARTHA BANDYOPADHYAY Created Date/Time: 09-Jan-2026 11:33 AM Tender Title: Electrical installation with maintenance works of the mech. and traffic section in the Terminus-Cum-depot of SBSTC at Digha Dist. Purba Medinipur. Tender ID: 2025_SBSTC_953563_7