Loading…
Loading…
61,341 results • Best match
Temporary arrangement of Electrical Installation Work for EVM Commissioning and Strong Room at various venues in the District of Jalpaiguri i.c.w. West Bengal Legislative Assembly Election - 2026.
Cable Laying: Providing & installation on hire main wiring with 1.1 KV grade Al. Conductor PVC/ XLPE armoured cable of following sizes including laying in trench (at least 230 mm below ground) including dismantling the same and mending good the damages.(for 3 days)
ARMO electrical works at FSD Poonch under DO Jammu
LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and 135 lm/Watt). Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) 5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and 135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C):100 Watt
Enhancing Built environment accessibility for person with disabilities under Accessible India Campaign (Sugamya Bharat Abhiyan) in Bio- Chemistry Building, within the campus of MCH, Kolkata ---- Electrical Installation Work---- Part (B) E.I WORK
M/s Singh Electrical Works (BID ID -8086779)
Custom Bid for Services - Supply, Transportation, Installation, Civil & Electrical Works for Pre-Fabricated/Porta cabin Two room set at RHQ premises of RHQ Building at Lucknow Similar Category Operation And Maintenance Of Substation
Civil & Electrical Works for Pre-Fabricated/Porta cabin Two room set at RHQ premises of RHQ Building at Lucknow Similar Category Operation And Maintenance Of Substation
GENERAL-Construction of Five Storied Building for Vigilance and Anti-corruption Bureau office in TVM at Muttathara, Thiruvananthapuram - Phase 1-Electrification-General Electrical Work-1-Balance electrical work for Cellar and Ground floor
OD181242/2025-2026:Wiring through EXISTING CONDUIT - Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
Electrical works related to repair renovation works of the Directorate of Agriculture situated on the 1st floor of Jessop Building 63 N.S Road Jessop Building Kolkata 700001.Electrical works.