Loading…
Loading…
61,333 results • Best match
Electrical works for Construction of Model Ayush OPD (SITC of Electrical works and SITC of AC Machine and Power backup at SHD Gorubathan BPHC, Kalimpong, GTA.
Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting
GENERAL-Womens Polytechnic College, Kaimanam - Overall maintenance of workshop building-Electrical maintenance-General Electrical Work
Work Name:GENERAL-Womens Polytechnic College, Kaimanam - Overall maintenance of workshop building-Electrical maintenance-General Electrical Work
Renovation of Electrical Works of Divisional District Hospital attached with Medical College, Mirzapur.
Renovation of Electrical Works of Divisional District Hospital Attached with Medical College, Distt- Mirzapur.
Supply Installation Testing and commissioning of Water cooler cum Purifier along with allied electrical works at 4th to 9th floor of SHTO Building for Directorate of Drugs Control, Kolkata.
Supplying & Fixing CRC sheet metal (16 SWG) JB-cum- Switch Board of the 200 x150 x65 mm sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl.bakelite/Perspex/coloured Perspex (wall matching colour) top cover 3 mm thick flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works.
Providing Electrical Installation work in Zila Parishad Building at District Rewari
Laying Cable Work in Various Faculties , Jai NarainVyas University, Jodhpur.
Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade direct in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) , with procedure as per following points:- (a) Make a river sand bed of height 125 mm along the trench, (b) Lay the cable in the middle of the trench, (c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth