Loading…
Loading…
6,391 results • Best match
Bifurcation of 11 KV Sanjeevpuram feeder emanating from 33/11 KV Zamisthanpur SS and Srinivasa Nagar feeder emanating from 33/11KV Seethaphalmandi SS by erection of new 11KV feeder from 33/11KV Seethaphalmandi SS which involves laying of 1.46KM 11KV 3X300Sqmm XLPE UG cable (Double Run) up to the existing Pole of the autorecloser Point and Line AB Switch near Vinayaka Gods Power Gym along with erection of 1No. 11 KV feeder VCB at 33/11KV Seethaphalmandi SS in Seethaphalmandi Section of Padmarao Nagar Sub-Division in Paradise Division of Secunderabad Circle under T and D Improvements to original works under General Category.
Fabrication of struc.with welding.
Ward number 54 urvarak Nagar mein V N dire factory ke nikat sarkari Bhumi per Park Nirman ka karya.
P/F of M.S Grill work with fabrication required shape and size with all complete of work.
Imp of Passage and Drainage system
PROVIDING FABRICATION AND FIXING STAINLESS STEEL CIRCULAR PIPE RAILING OF 10 GAUGE
Labour Contract For KCP Boiler Main Bank Tubes Damaged Length 2 Mtr Renewal Work With IBR Approved
Labour Contract For KCP Boiler Main Bank Tubes Damaged Length 2 Mtr Renewal Work With IBR Approved 1.Dismantling of damaged KCP Boiler Main Bank Tubes damaged portion from bottom drum to 2 mtr height with profile bend as identified the Boiler Engineer. Approximately –a) 20 Nos of pluged tube full length 8 Mtr, b) 150 Nos damaged tubes 2 Mtr height from bottom drum. 2. Damaged old tubes are to be handed over to scrap yard through store after weighment as per the Engineers instructions. 3. Before fixing of new tube bottom drum tube holes to be corrected with butling and other end tube making grinding for joining of tubes . 4. Size of the Tube 82.5mm OD x 3.66mm thick x 7.0 to 8.0 Mtrs Length approx. given by the mills. 5. New tube should be fabricated as per our drawing profile drawing No: TRT/BL/011(B) with above mention size replacement only. 6. Fixing of new fabricated tube in position with one end expended in bottom drum and other end to be welded in existing tube – 150 Nos and 20 Nos of new tube fixing in one end connecting in bottom drum other end connected in top drum by expanding. 7. Neccessry refractory tiles clamping fixing bolt to be provided by the contractor ( Clamp and bolt given by the mills). 8. Necessary fabrication drawing should be prepared by the contractor and got approved by Dy. Director of Boiler Chennai circle. 9. After erection of the tubes the boiler hydraulic test as to be contractor if presence of Deputy Director of Boiler.
Conversion of existing old CT's, PTs & overaged LA's at TSS, SP, SSPs to improve safety and reliability in Kurla district of Mumbai division.
18Supply, fabrication and erection of steel chequred plate for trench covers inside control room
Need Repair for Anganwadi Wall and Window at Siruthondamadevi West in Arasadikuppam Panchayat
Fabrication and Supply of MILD STEEL WINDOW of size 0.90m X 1.20m with Single leaves,outer frame made of 35x35x5 mm equal M.S.L. angle and shutter frame made of 25x25x5 mm equal M.S.angle for horizontal and vertical members and the shutter frame strengthened by stiffeners of 2 Nos horizantal and 3 Nos diagonal for each shutter using M.S. flat of size 20x5 mm fully covered with 18 guage plain M.S. full sheet whelded with shutter frame neatly and also fixing by welding 6 Nos holdfasts,2 Nos of wind appliances, 3 Nos of tower bolts, 1 No aldrop 3 Nos of handles, fixing the shutter with 6 Nos of hinges without frame of the door including painting the whole unit with one coat of best quality of redoxide primer.