6,518 results • Best match
REPAIR / REPLACEMENT OF LT CABLES, LT SWITCHGEARS, EARTHING AND CONNECTED WORKS OF LIFTS UNDER GE (UTILITY-II) VISAKHAPATNAM
Design, fabricate, supply, installation, testing and commissioning of outdoor type cubicle panel board with inside panel suitable for 3 phase 4 wire, 415 Volts, 50 Hz, AC supply system, factory fabricated in an approved factory having modern fabrication facilities, made out of CRCA sheet steel of 3 mm thick for outer shell and 2mm thick for inner shell with front openable door with two point locking arrangement i.e. Key locking system & pad-locking. Complete panel board shall be applied with powder coat painting of approved shade duly pretreated with seven tank process and suitable packing material for IP-54 degree of protection and including provision of 50 mm x 50 mm x 6 mm angle iron base frame of suitable size for mounting the panel board with a minimum ground clearance of 900 mm above GL to the bottom of panel including PCC foundation with PCC 1:3:6, type C1 using 20mm graded stone aggregate. Detachable gland plates including double compression stainless steel cable glands of suitable size shall be provided for all incoming and outgoing cables. Steel plate Danger Notice Board(01 No) LT 415/440 Volts, and manufacturer's name plate shall be riveted on external doors of feeder pillar box. The size of panel board shall suitable for accommodating and including provision of following switchgear, control gear and accessories including internal wiring with suitable gauge of copper cables complete including taking down of old existing LT panel, complete all as specified and directed by Engineer-in-Charge :- Incoming :- (a) MCCB AC 3 Phase 415 V, 50Hz 4 pole, 250 A, breaking capactiy 50kA, Ics=100% Icu with adjustable type thermal and magnetic setting relays - 01 No (b) Digital Voltmeter with selector switch - 01 No (c) Digital Ammeter with selector switch - 01 No (d) LED Pilot light indication lamps for R,Y,B phases - 01 Set of 03 Outgoing :- (a) MCCB AC 3 Phase 415 V, 50Hz 4 pole,100 A, breaking capactiy 25kA, Ics=100% Icu with adjustable type thermal and magnetic setting relays - 05 Nos
Upgradation of Electrical Power Supply System and Associated Cabling Works at S-60, RCL South Site, BARC, Trombay, Mumbai 400085
Fabrication and supply, installation of M.S. Support as per technical specification.
REPAIR/MAINT OF EXTERNAL WATER SUPPLY CI/GI/PPR PIPE LINES, VALVES ETC AT SE FALLS AREA UNDER GE SHILLONG
Suplying, fabricating & fixing structural mild steel angle iron, flat iron, sheets and brackets etc for fabrications of valve chamber cover, chasis for pump, PS tank plates, PS tank covers, clamps and back plates including nuts, bolts and washers, welding banding cold or hot drilling holes for insulators bolts in any shape or size complete all as speciified and directed.
Construction of VDCC Bank Training Centre Building at Vijayapur
Steel Fabrication. Supplying fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials machinery labour cleaning straightening cutting bending hooking laping/welding jo...
Execution of Civil, Architectural finishing, MEP and other Miscellaneous works for Construction of Operation Control Centre (OCC) at Sarai Kale Khan Namo Bharat Station.
Supply, Fabrication, installation and testing of Galvanized Steel (GS) sheet metal ducts & finally applying fire rated paint as per BS 476 Part 24 (Site FABRICATED DUCTS For Connection /Plenum etc.) in accordance with the approved shop drawings complete with all accessories like vanes, flanges, suspension rods , anchor bolts, GI bolts & nuts, etc., as per specifications.
DAY TO DAY COMPLAINTS OF EXTERNAL ELECT SUPPLY AND ALLIED WORKS IN FLAMING ARROW UNITS AT NAMS UNDER GE NAMS
M&L for replacement of Existing Unserviceable LT feeder pillar box out door type double door and single shutter front open including locking arrangement system made out of MS sheet of 3.15 mm CRCA sheet of size 0.9x0.9x0.6 mtr and double door,canopy,dust proof, bottom cable entry plate and gland for cable size150/120/95/70/50/25/16/10 sqmm 3.5 core suitable MS angle iron 50x50x6 mm with aluminium busbar size 400Amps with Incoming MCCB 250 Amp 4 pole system mounted on hygroscopic insulators bus bar including suitable nut, Bolt and Washer(16 Nos) , & including powder coated paint with and providing necessary foundation/plateform of the feeder pillar legs size 40cm below the ground and 60 cm above the ground complete from groundwith PCC 1:2:4 type B2 including provision of for incomong and outgoing cable gland, thimbling for old / new cables as per site requirement and proper finshing as per existing surface complete all as specified and directed by Engr- in- Charge. Note: Drawing for LT feeder piller box shall be got approved from GE before fabrication consisting of following:- (i) Incoming : MCCB 04 Pole 26 KA, 250 Amp, 415 Volts, fixed thermal & magnetic release (Qty - 01 Nos) (ii) Aluminium bus bar suitable size 3 phase, 4 wire 400 Amp,415 V, duly insulated - set of 4 (iii) Digital Volt meter 0-500V with slector switch. (iv) Digital Amp meter 0-400 amp with CT and selector switch. (v) Indicating lamp (RYB)LED Type - set of 3