Loading…
Loading…
1,001 results • Best match
Supply of various fire items as per schedule of requirements
Description :FIRE EXTINGUISHER, ISI Marked Detect Fire Portable Fire Extinguisher ABC Type 6 kg Epoxy polyester Dry powder coating constant pressure Dry powder IS14609/IS 4306 minimum effective discharge %85 Composite. [ Warranty Period: 30 Months after the date of delivery ] ] Consignee Sr.DSC/LMG, NFR Assam 34.00 Numbers
Strengthening /up-gradation of infrastructure of HWMI Bikaner- IEC Lab and Mobilization of Field Visits for Farmers, repair old diggi and misc. items etc,Hydrology and Hydrometeorology Lab, GIS and remote sensing Lab,Providing /Supplying (P-463)
Providing and fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture as per direction of Engineer-in-charge of size 595 X 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanizing @120 grams per sqm) consisting of main „T‟ runner suitably spaced at joints to get required length and size of 24X38mm made from 0.33 mm thick (minimum) sheet, 1200mm centre to centre, and cross „T‟ of size 24X32mm made out of 0.33mm (Minimum) sheet, 1200mm long spaced between main „T‟ at 600mm centre to centre to form a grid of 1200X600mm and secondary cross ‟T‟ of length 600mm and size 24X32mm made out of 0.33 mm thick (Minimum) sheet to be interlocked at middle of the 1200X600mm panel to form grid of size 600X600mm resting......on periphery walls/partitions on a perimeter wall angle precoated steel of size (24X24X3000mm made of 0.40mm thick (minimum) sheet with the help of rawl plugs at 450mm centre to centre with 25mm long dry wall screws @ 230mm interval and laying 15mm thick densified edged calcium silicate ceiling tiles of approved texture in the grid including cutting /making opening for services like diffusers, grills, light fitting, fixtures, smoke detectors etc., wherever required, Main „T‟ runners to be suspended from ceiling using 50 mm long M 6 dash fasteners, 6mm G.I. fully threaded rods with galvnised steel L cleat level adjusters of size 80x25x2mm, spaced at 1200mm centre to centre long main „T‟ bottom exposed with 24mm of all T-sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawing and as directed by engineer-in-charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs)having area less than 0.30 Sqm. The calcium silicate ceiling tiles shall have NRC.
Regarding the purchase and supply of stationary and miscellaneous items required for Police Stations, Sub-Police Stations,AOP , and various operational branches in Gadchiroli District.
· HANUTECH 220V AC Industrial Hooter Single Phase Steel Siren Heavy Duty Fire Alarm Sound Range 1.5 KM For School,Collages,Industries Wired Door Chime
M and R to NRB at Udyog Sarathi Building.. Renovation Work of Jt. CEO office by providing meeting room, waiting area and Staff cabin at Old Land Section Second Floor at Udyog Sarathi, Andheri.
Dismantling old electrical fixures of all types i.e. switch boards, lights, smoke detectors etc. including its wiring and stacking of serviceable material and disposal of unserviceable material with all lead and lifts.
Procurement of Specified River sand for mortar/concrete and Black sand for trench/plinth filling in different areas of Dukli R D Block under R D Agartala Division of West Tripura District
Providing and fixing of PVC interlocking ceiling panels (12ft x 10 inches) of specified materials (Best quality) of size 600x600 mm in true Horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams/sqm, both side inclusive) consisting of main "T' runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30mm thick (minimum) sheet, spaced at 600 mm center to center and cross "T" at 600 mm center to center to form a grid of 600x600 mm and secondary cross "T” of length 600 mm and size 24x25 mm made of 0.30 mm thick(minimum) sheet to be interlocked at middle of the 600x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including required cutting/making, opening for services like different, grills, light fittings, fixtures, smoke detectors etc. all complete for all heights as per specification, drawings and as directed by Engineer-in-charge
Procurement of Specified River sand for mortar concrete and Black sand for trench plinth filling in different areas of Dukli R D Block under R D Agartala Division of West Tripura District
Providing and fixing of PVC interlocking ceiling panels (12ft x 10 inches) of specified materials (Best quality) of size 600x600 mm in true Horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams/sqm, both side inclusive) consisting of main "T' runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30mm thick (minimum) sheet, spaced at 600 mm center to center and cross "T" at 600 mm center to center to form a grid of 600x600 mm and secondary cross "T” of length 600 mm and size 24x25 mm made of 0.30 mm thick(minimum) sheet to be interlocked at middle of the 600x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including required cutting/making, opening for services like different, grills, light fittings, fixtures, smoke detectors etc. all complete for all heights as per specification, drawings and as directed by Engineer-in-charge