Loading…
Loading…
952 results • Best match
CA NO CE CHZ CHM T 16 2025 26 ADDN ALTN UPGRADATION RESTORATION AND ALLIED WORKS AT CH CHANDIMANDIR
Air ball Diffuser of size 2' x 2', white in colour made of aluminium, powder coated suitable for existing HVAC system including all connection complete all as specified and directed.
REPAIR REPLACEMENT OF MAJOR DEFECTIVE PARTS OF AC PLANT SUCH AS COMPRESSOR, AHU MOTOR CHILER UNIT HEATING SYSTEM AND ALLIED WORKS OF KHASTAN WORKSHOP AT NAD EXPLOSIVE AREA AT NAVAL STATION KARANJA
Supply and fixing of connector in HVAC panel 6 Amp to 35 Amp 230 V 2 way complete all as specified and directed.
REPAIR/ SERVICING OF DG SET, LT PANELS, AMF PANEL EFFLUENT TREATMENT PLANT AND MISC WORK AT MH SHIMLA UNDER GE (I) JUTOGH
M&L for comprehensive maintenance of HVAC unit comprising checking of compressor, controls such as pressure cut outs, cooling coil, blower motor, checking/ arresting of gas leakage if any incl necessary charge of gas etc of 8.5TR (02 Nos) cap, complete all as specified and directed.
DETAILED ENGINEERING CONSULTANCY SERVICES FOR STRUCTURAL DESIGN AND DRAWINGS FOR PROVN OF SWIMMING POOL INCLUDING SOIL INVESTIGATION UNDER GE 970 EWS
(A) Preparation and submission of self sufficient Structural Designs & Drgs for including Structural details, Structural notes conforming to latest standards IS-456, IS-800, IS-875, IS-816, IS-1893, IS-2062, IS-4326, IS-13920 and any other latest and relevant Indian Standard of the building as per the Arch Drgs. The description of buildings, swimming pool, sump and balancing tank etc are as under and as specified in tender documents. The parameters for Structural Design are as under:- (i) Changing Room -75 Sqm (ii) Store Room - 15 Sqm (iii) Sanitary Annexe (a) WCs 4 Nos @ 2 Sqm each=8 Sqm. (b) WHB 4 Nos @ 1 Sqm each=4 Sqm (c) Urinals 4 Nos @ 1 Sqm each=4 Sqm (d) Shower and footbath 07 Nos @ 3 Sqm each=21 Sqm (iv) Total area (i) to (iii)=127 Sqm Plus 85% PACF= 234.95 SQM (v) Space Area for swimming pool and others:- Size @ 41.19 x 33.50 M = 1379.86 Sqm Say 1380.00 sqmtr . S&F Pre-coated MS structure with coloured coated galvalume sheet 0.50 mm thick including necessary excavation , earthwork, foundation etc all complete as per arch drg and specified - 1380 Sqm (vi) Plant Room - 170 Sqm (vii) Plant room for CHS/HVAC -- 200 Sqm (viii) Swimming Pool size 25 mtr x 13.5 mtr and comprising of following:- (aa) Side walk :- (a) At either 5 mtr wide (b) At either 2.5 mtr wide (ab) Diving Board :- (a) Spring board at 01 mtr - 01 Nos (b) Spring board at 03 mtr - 01 Nos (ac) Cascade (ad) Porch , Entrance Lobby (ae) Balancing Tank (100000 Ltr Cap) (ix) UG Sump 50000 Gallon Cap - 01 No
DETAILED ENGINEERING CONSULTANCY SERVICES FOR STRUCTURAL DESIGN AND DRAWINGS FOR PROVN OF SWIMMING POOL INCLUDING SOIL INVESTIGATION UNDER GE 970 EWS
(A) Preparation and submission of self sufficient Structural Designs & Drgs for including Structural details, Structural notes conforming to latest standards IS-456, IS-800, IS-875, IS-816, IS-1893, IS-2062, IS-4326, IS-13920 and any other latest and relevant Indian Standard of the building as per the Arch Drgs. The description of buildings, swimming pool, sump and balancing tank etc are as under and as specified in tender documents. The parameters for Structural Design are as under:- (i) Changing Room -75 Sqm (ii) Store Room - 15 Sqm (iii) Sanitary Annexe (a) WCs 4 Nos @ 2 Sqm each=8 Sqm. (b) WHB 4 Nos @ 1 Sqm each=4 Sqm (c) Urinals 4 Nos @ 1 Sqm each=4 Sqm (d) Shower and footbath 07 Nos @ 3 Sqm each=21 Sqm (iv) Total area (i) to (iii)=127 Sqm Plus 85% PACF= 234.95 SQM (v) Space Area for swimming pool and others:- Size @ 41.19 x 33.50 M = 1379.86 Sqm Say 1380.00 sqmtr . S&F Pre-coated MS structure with coloured coated galvalume sheet 0.50 mm thick including necessary excavation , earthwork, foundation etc all complete as per arch drg and specified - 1380 Sqm (vi) Plant Room - 170 Sqm (vii) Plant room for CHS/HVAC -- 200 Sqm (viii) Swimming Pool size 25 mtr x 13.5 mtr and comprising of following:- (aa) Side walk :- (a) At either 5 mtr wide (b) At either 2.5 mtr wide (ab) Diving Board :- (a) Spring board at 01 mtr - 01 Nos (b) Spring board at 03 mtr - 01 Nos (ac) Cascade (ad) Porch , Entrance Lobby (ae) Balancing Tank (100000 Ltr Cap) (ix) UG Sump 50000 Gallon Cap - 01 No
Supply laying installation and testing of underground chilled water pipeline for upcoming Hall 15 building block 3 and block 4 from existing chilled water grid near CEM building IIT Kanpur
Supplying, laying/fixing, testing and commissioning of following nominal sizes of chilled, of pre-insulated heavy MS pipe i/c accessories as bends, tees, reducers etc. with homogeneous rigid CFC-free polyurethane foam (PUF) insulation of relative thickness as per CPWD HVAC specification 2024 of min density 48 kg/cu.m, 90% minimum closed cell content, and outer surface having cladded with watertight, corrosion protected and UV resistant HDPE pipe of relative thickness, having minimum compressive strength of 2.7 kg/sqcm, and thermal conductivity of 0.02 W/mK etc complete as standard specification with all fitting as required. Note: The pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS: 1239 and pipes size above 150 mm shall be welded black steel pipe heavy from minimum 8 mm thick M.S. sheet for pipes upto 450 mm dia