Loading…
Loading…
947 results • Best match
Daytoday preventive, corrective and breakdown mtc. of HT , LT elec. installations, Fire system, Lifts, Chiller Plant, HVAC, DG set, UPS etc. for uninterrupted power supply at PMSSY-III Building, Bankura,-Internal E.I mtc. with various rated LT Panel
11. All type of maintenance & operation tasks incl. proper testing, checking etc. with necessary action of preventive & corrective/rectifying measure in case of any fault/abnormality are to be accomplished with proper care, safety & precaution measure and all these tasks are to be recorded in separate Log book which are to be signed by highly skilled Electrician deployed by the contractor with duly verification & signed by concerned Assistant Engineer(Electrical) & Junior Engineer(Electrical) in regular manner. 12. The agency will have to immediately replace any or all members of the electrical maintenance staff, who has been reported against. 13. The agency shall provide photo identity cards to all the maintenance staff employed, including substitutes. 14. . In case of power failure or development of any unfavourable situation, the agency will have to communicate with concerned WBSEDCL authority and extend co-operation to concerned WBSEDCL authority in restoration of power supply. Meanwhile the agency will have to operate the switching mechanisms of interconnections among available sources at suitable locations to maintain power supply at important locations by monitoring electrical loads in consultation with concerned Junior Engineer/Assistant Engineer. 15. The on-duty Maintenance Staff must wear specially designated fluorescent coated outfit denoting PWD( Elect) clearly provided by the agency. 16. The Agency should depute his Supervisor to supervise the whole electrical components in the whole campus as per scope of the works. 17. The agency will take care to prepare the requisition of materials required for the maintenance within his jurisdiction well in advance and submit the same to the concerned Junior Engineer so that no delay in repair / replacement cause trouble in the system & hampering of the Hospital service thereof. 18. The agency will also have to attend immediately emergency calls at the site with staff, tools etc. on demand.
RMO E and M Services at National Law University and Delhi Judicial Academy, Sector-14, Dwarka, New Delhi SH- Providing and fixing of fire Retardant Electrical flooring in HVAC plant Room and Lift Machine Rooms at Various locations
eTendering System Government of NCT of Delhi Created By: Chaman Lal Verma Created Date/Time: 06-Jan-2026 04:49 PM Tender Title: RMO E and M Services at National Law University and Delhi Judicial Academy, Sector-14, Dwarka, New Delhi SH- Providing and fixing of fire Retardant Electrical flooring in HVAC plant Room and Lift Machine Rooms at Various locations Tender ID: 2025_PWD_283934_1
ARMO of Internal EI & Fans, Pump Set, Lift, Substation Equipment, Fire Fighting & Sprinkler System, Fire Alarm System, HVAC System, CCTV, LAN, IBMS & EPBAX System in Office Building for Customs Department at Jamnagar for year 2026-27. SH - Operation ... Sprinkler System , ... Alarm System & ...
Construction of Multi-storey academic building at NIEPA campus, 17-B, aurobindo Marg, new Delhi i/c water supply, sanitary installation, electrical installation, DG set, Substation, Lifts, HVAC, Firefighting system, LAN and external development work. SH: SITC of digital signage work)
Construction of Multi-storied academic building at NIEPA campus, 17-B Aurobindo Marg, new Delhi including water supply, Sanitary installation electrical installation, DG set, substation, Lifts, HVAC, Firefighting system, Fire alarm, LAN and external development work (SH : Miscellaneous air conditioning work)
Comprehensive Maintenance and Operation of HVAC System 600 TR (200 TR X 3# Blue Star Make) with all associated equipments and Material in Institute Building, Medical College, Patiala (Under Head User Charges).