Loading…
Loading…
2,147 results • Best match
REPAIR/MAINT OF FIRE HYDRANT SYSTEM AND SEWAGE PUMPS SETS AND CONNECTED ITEMS AT AF STN AMBALA UNDER GE (AF) AMBALA
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.50 m deep for laying of water pipe lines/taking out pipe lines and getting out in soft/loose of soil including forming bottom surface to required level and slope complete all as specified and as directed. Note: (i) Excavation work shall be carried out by hand (manually) and no mechanical excavation equipments (such as mechanical excavator or JCBs) shall be permitted. (ii) During excavation, in the event of any damage to existing water pipes or electric / JFC or OFC (Optical Fiber Cable) cables, the contractor shall be rectify or replaced by at their own expense.
Construction of the Directorate of Fisheries Office Building at Khapuria, Cuttack.
SITC of 6 core Single mode OS2 Unitube Armoured Optical fiber cable through existing conduit: The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125µm. Outdoor Corrugated Steel tape Central loose tube. ( Standard Approved: ISO 11801 2nd edition/ EN 50173-1:2002 / IEC 60794-1/IEC 60793-2-50 class B1.3 / EN 60793-2-50: class B1.3 / ITU Recommendation G.652.D - the oder ITU designations A, B and C are also fulfilled / OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled/IEEE 802.3 - 2002 incl. 802.3ae ) Jacket. Make: Systimax, Legrand, Panduit
Restoration of 33 kV S/C Line from Yeggo 132/33 kV Sub-Station to Kamba SHP (3x2 MW) Switchyard.
24 Fiber (DWSM) Optical Fiber Ground Wire (OPGW).
Building work
SITC of 6 core Single mode OS2 Unitube Armoured Optical fiber cable through existing conduit: The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125µm. Outdoor Corrugated Steel tape Central loose tube. ( Standard Approved: ISO 11801 2nd edition/ EN 50173-1:2002 / IEC 60794-1/IEC 60793-2-50 class B1.3 / EN 60793-2-50: class B1.3 / ITU Recommendation G.652.D - the oder ITU designations A, B and C are also fulfilled / OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled/IEEE 802.3 - 2002 incl. 802.3ae ) Jacket. Make: Systimax, Legrand, Panduit
Construction of Urban Development on 4th Floor in Dr. Nityanand Himalaya Sodh Kendra at Doon University Dehradun (Uttarakhand)
Labour chagres for optical fiber cable splicing and jointing with Termination.
Erection of 110 KV DC line on DC towers for making LILO arrangements in 110KV Kavanoor - Ilayankudi - Maravamangalam feeder to the proposed Athapadakki 110 KV SS (Loc.35 to Take off) Reach - IV
Laying , erection, testing and commissioning of 48core optic fiber (ADSS) cable with joints 40mm dia HDPE duct hose pipe, FODP and all accessories including all T&Ps,cost of labour, lead, lift, etc., complete.