Loading…
Loading…
2,147 results • Best match
Building works
SITC of 6 core Single mode OS2 Unitube Armoured Optical fiber cable through existing conduit: The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125µm. Outdoor Corrugated Steel tape Central loose tube. ( Standard Approved: ISO 11801 2nd edition/ EN 50173-1:2002 / IEC 60794-1/IEC 60793-2-50 class B1.3 / EN 60793-2-50: class B1.3 / ITU Recommendation G.652.D - the oder ITU designations A, B and C are also fulfilled / OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled/IEEE 802.3 - 2002 incl. 802.3ae ) Jacket. Make: Systimax, Legrand, Panduit
Civil and MEP works
OFC Cable - Supplying drawing and testing of 12 core Single Mode (OS2) Outdoor armored Jell-Free Dry Tube Optical Fiber Cable (OFC), LSZH through wall/tray with saddle in a maximum distance of 30 CM with all accessories as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation.
Annual Maintenance contract for EPABX, UPS, DG, AC and Electrical Installations at Common Facility Centre at Ratnagiri . (Two Years period).
Supplying and erecting 6 fibers LSZH armoured multimode optical fiber cable with, core dia 50/125 µm (OM3), suitable upto 10 GBPS, compliant to IEC 60793/IEC 60794 standards, on wall/ ceiling or laid in provided pipe/trench as per specification no. WG-ELVC/OFC
CONSTRUCTION OF COURT BUILDING AT. MANGARULPIR TQ. MANGARULPIR DIST. WASHIM (WITH ELECTRIFICATION)
Supplying and erecting LSZH armoured multimode optical fibre cable with 6 fibres, core dia 50/125 µm (OM3), suitable upto 10 GBPS, ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification no. WG-COC/OFC LSZH
Nizamuddin Bridge to DND Flyway (Western Bank) - 163 Hectares (Kalindi Aviral Extension)-Other Civil, Electrical and Horticulture works.
Supplying and drawing following core Fiber Optic Cable having corrugated steel armoring. The Fiber should be SM Fiber Central -loose tube filled with Thixotropic jelly, duly following Standards: ISO 11801, IEC 60793-1/60794-1-2, ITU-T-REC G.652D and Telecordia GR-20-core, High quality Electro Chromium Coated Corrugated Steel tape (ECCS ) and HDPE- Sheath, Operating ambient Temperature should be – 5 0C to +50 0C and Storage Temperature shall be – 5 0C to +50 0C, Max Attenuation ± 0.36 (db/ km) at Operational Wavelength 1310 nm and ± 0.22 db / km at Operational Wavelength 1550 nm. type of fiber should be 9/125 / G.652D & Refractive Index should be 1.4670/1.4675. The value for Mode-filed, Cladding Diameter 9.2 ± 0.4 µm and 125 ± 0.7 µm correspondingly. The Dispersion value 3.5 18 ps/nm-km and PMD value 0.2 ps/km and Cable Cutoff wavelength 1260 nm i/c splicing & marking etc complete as required. . Single Mode 6 Core Optical fiber cable
External Electrification to intake well WTP and zonal reservoirs in connection to the work Augmentation of water supply system along with ancillary works for Patnagarh town.
LAYING OF OFC CABLE: Supply and Laying of 12 core enamoured Optical fibre cable ( OFC. Fibre glass with F-G 62.5/125micron, 2.6DB/KMF600) to various sites through HDPE pipe /in Air ( pole to pole ), relaying testing of each cable drum for each fibre and tahing the OTDR traces, submission of OTDR traces (in hard as well as soft copy) to Engineer-in-charge/Site Engineer.