Loading…
Loading…
1,527 results • Best match
Extension of existing control room building for accommodate the newly proposed additional panels at Ayyermalai 110/33-11KV Grid Substation at Karur
Fabricating Supplying and fixing in position of Aluminium anodized natural colour matt finish Openable type glass window (3 leaves) with fixed glazing at top to a height of 0.3m with alminium grill for glazed portion in all floors having the Aluminium section such as outer frame of section (418/code) of 37.70x33mmx2mm @ 0.50kg/m, center mullions of (code 9153,2.50mm thick) 59x33x2.5mm @ 0.936kg/m,Z section of having 24.00mm vertical and width of 33mm @2.50mm thick.Confirming to code No [email protected]/m Aluminium clips of 3.60 length having total weight of 0.40kg or 0.109kg/m with neccessary accssories such as rubber beadings, special hinges, handle including supplying and fixing 4mm thick plain glass including cost of all materials, labours, power consumption required for fabrication, drilling holes in RCC column slab, masonry walls wherever necessary with power drills to the required extent and make good to the original conditons after fixing and also as directed. All the Aluminium sections are to the anodised with matt finish under electrically controlled conditons in accordance with Is 1868/1962 for an average anodic film thickness of 15 microns etc. Complete.
Shifting of Power Grid/Augmentation of 100 KVA to 250 KVA Substation at Degree College Beerwah along with relocation from existing Position.
Supply, installation, testing and commisioning of 250 kVA ,11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, CU. wound , and with LV Cable Box having detachable Aluminium Gland plate 11/0.433KV, 3-phase(EE Level-II) complete in all respect as per Standards.
Work of creation of 01 no. 33kv line bay of M/s Power Grid Teleservices Limited (PGCIL) Manesar at 220kv Substation Panchgaon
Work of creation of 01 no. 33kv line bay of M/s Power Grid Teleservices Limited (PGCIL) Manesar at 220kV Substation Panchgaon
ANNUAL STAGE CONTRACT FOR CARRYING OUT PREVENTIVE ROUTINE BREAKDOWN MAINTENANCE OF VARIOUS 132 BY 33 KV GRID SUBSTATIONS AND ALLIED 132 KV TRANSMISSION LINES FALLING UNDER THE JURISDICTION OF TLMD III AMARGARH
Protection System:-Checking of relays and application of CCL4 for cleaning, carrying out relay testing replacement of worn out defunct relays, testing of event logger/disturbance recorder if any, checking and replacement of control wiring if required of the subject Grid Substation.
CONSULTANCY SERVICES FOR CONCURRENT MONITORING AND THIRD PARTY EVALUATION FOR THE WORK OF CONSTRUCTION OF BALANCED PIPE LINE AND DISTRIBUTION CANAL NETWORK TO MC THOLALU LIS AND CONSTRUCTION OF SOPANAM, PROTECTION WORK TO NUGU RIVER NEAR MC THOLALU AND KANDALIKE VILLAGE AND IMPROVEMENTS TO ETHIGE TANK OF HD KOTE TALUK MYSURU DISTRICT
CONSULTANCY SERVICES FOR CONCURRENT MONITORING AND THIRD PARTY EVALUATION FOR THE WORK OF CONSTRUCTION OF BALANCED PIPE LINE AND DISTRIBUTION CANAL NETWORK TO MC THOLALU LIS AND CONSTRUCTION OF SOPANAM, PROTECTION WORK TO NUGU RIVER NEAR MC THOLALU AND KANDALIKE VILLAGE AND IMPROVEMENTS TO ETHIGE TANK OF HD KOTE TALUK MYSURU DISTRICT
Proposed Turnkey work for Hybrid DSA machine at Ground Floor Main Building - Civil and Electrical
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main"T" runners to be suspended from ceiling using GI slotted cleats ofsize 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanisedbutterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mmcenter to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete forall heights as per specifications, drawings and as directed byEngineer-in-charge.