Loading…
Loading…
1,087 results • Best match
Supply of Double Beam UV VIS Spectrophotometer
1.01 UV VIS Double Beam Spectophotometer Make : Shimadzu, Model : UV-19001 Enables easy operation with an intuitive on-screen user interface -includes large, easy-to-see icons, and can be controlled with a finger or stylus pen Obtains high-accuracy spectra in just a few seconds Delivers excellent photometric repeatability accuracy of 0.0002 Abs max. (0.5 Abs and 1.0 Abs), enabling more accurate quantitation and the detection of low-concentration samples Includes multiple measurement modes, such as photometric, spectrum, quantitation, kinetics, time course and biomethod New to the UV-1900i are validation functions that are compliant with the United States Pharmacopeia (USP) and the European Pharmacopeia (EP). The instrument also can run checks for nine JIS items and the Japanese Pharmacopoeia (JP). Operators can save checked conditions and results and easily refer to them as needed. In combination with Lab Solutions TM DB/CS (not included),UV1900i will comply with FDA 21 CFR Part 11 and PIC/S GMP guidelines . Wave number Range : 190 to 1,100 nm Spectral bandwidth : 1 nm (190 to 1,100 nm) Wavelength display :0.1 nm increments Wavelength setting : 0.1 0.1 nm increments (1 nm increments when setting 0.2 0.2 scanning 0.3 range) Wavelength Accuracy : ± 0.1 nm at D2 peak 656.1 nm, ± 0.3 nm for entire range Wavelength Repeatability : ± 0.1 nm Wavelength slew rate : About 14,500 nm/min Wavelength Scanning Speed : 3000 to 2 nm/min, 29000 nm/min when survey scanning Lamp interchangeable wavelength : Automatic interchange linked to wavelength. Interchange can be set freely in the range of 295 to 364 nm (0.1 Stray Light : Less than 0.02% at 220 nm (Nal), Less than 0.02% at 340 nm (NaNO2), Less than 0.5% at 198 nm (KCL) Photometric System : Double beam optics Photometric range : Absorbance : -4 to 4 Abs Transmittance : 0% to 400% Photometric Accuracy : +/- 0.002 Abs at 0.5 Abs +/-0.004 Abs at 1.0 Abs +/-0.006 Abs at 2.0 Abs Photometric repeatability : Less than +/- 0.0002 Abs at 0.5 Abs Less than +/- 0.0002 Abs at 1 Abs Baseline stability : Less than 0.0003 Abs/hr (700 nm, one hour after light source turned ON) Baseline Flatness : Less than +/- 0.0006 Abs (1100 to 190 nm one hr after light source turn ON. Noise level : Less than 0.00005 Abs (700 nm) Light source : 20-W halogen lamp and Deuterium lamp, Built in light source auto position adjustment Monochromator : LO-RAY-LIGH grade blazed holographic grating in Czerny-Turner mounting Detector : Silicon photodiode Sample compartment : Internal dimension W110X D250X H115 mm, Distance between light beam : 100 mm Power requirements : AC 100, 120, 220, 230, 240V, 50/60 Hz, 140 VA Environmental requirements : Temperature: 15°C to 35°C Humidity: 30% to 80% (without condensation; 70% max, at 30°C or higher) Dimension : W450xD501XH244 mm Detector : silicon photodiode Output device : USB memoryData file save in text format or UVPC format. UVPC-format file can be read directly by UV probe and Lab solution TM UV Vis PC compatibility : External control possible via USB Also Compatible with Microsoft licensed windows 10 Professional Display : 24 bit colour touch screen Supported Languages : Japanese, English, Chinese, Spanish, Mexico, Portuguese Supplied with below accessories 1.071-60845-01 Cord Set,3VTJ1 / 3VTJA H05VV-F 2. 10mm Rectangular Quartz Cell - 1 Pair 3. USB Cable for interfacing instrument with PC/Printer Note: PC with win 10 professional licenses is requiring for above system is in your scope and responsibility A1 1 No 55 3 Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
Procurment of Universal Length Measuring M/c
Licensed Software ( For thread Plug & Ring gauge measurements and Plain Plug & Ring Gauge measurements only)
Supply, Installation, Testing and Commissioning of Advanced TL/OSL Spectrometer along with Accessories at Central Discovery Centre, BHU
One branded PC having a minimum of an i7 13 Gen processor, 16 GB RAM, 512 GB SSD, 24-inch FHD monitor and optical drive, for offline data analysis with licensed software
Electrical Transient Analyzer Program (ETAP) along with Short Circuit and ground grid system modules
Electrical Transient Analyzer Program licensed software
ABT Energy meter
240114 AMR SOFTWARE Perpetual Licensed Windows based software M Cubed 100 for configuration, downloading and managing data of Apex 150 ABT meters. Compatible with all Secure ABT and interface meters installed at site with one system activation and 66 months Validity.Suitable for Meter parameter configuration and password management Reading of load survey, tamper logs event logs Data conversion export to Excel or CSV or XML or DDL formats,Meter time synchronization utilities.Communication driver pack included serial or USB or optical or RS 485 or Ethernet Compatible with latest Windows OS Windows 10 or 11 OEM activation key to be provided.User manual installation guide, and training material must be provided.
Advanced High Energy Linear Accelerator System with Accessories (RFA and Immobilization Device Set)
Antivirus protection Please Specify