Loading…
Loading…
1,287 results • Best match
Construction of Community Centre on Khasra No. 0//78, 0//127 at Indri Road under C M Announcement scheme Code No. 29239 Dated 04/12/2025 Ladwa
[32.70.2]Supply Installation testing commissioning of Solar Photovoltaic grid connected roof top Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- (a) Solar Photovoltaic Module manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. (b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz plus /- 2.5 Hz, output voltage suitable to generate AC (c) Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degrees C. The PCU shall adjust the voltage and frequency level to suit grid frequency (d) Data Monitoring System complete with accessories. (e) Fixing of Array junction box and Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. (f) Lightning and surge voltage protection. (g) Connections and Interconnections by supplying and fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying and fixing of necessary channel/conduit lugs and other accessories etc. as required. 2. Above 10 kWp and up to 100 Kwp [Through Rate]
Construction of New Model Sub Registar Office at Radhanpur Dist-Patan (2nd Attempt)
Tied Solar Power Plant with
CONSTRUCTION OF MULTIPURPOSE ADMINISTRATIVE BUILDING IN SELAGARH FOR PURNAGIRI MELA, DISTRICT CHAMPAWAT
Solar Photovoltaic Plant Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.
Construction of RCC Jetty with Approach Road on the river Dansa at Rajani Ghat GP Khulna Block Sandeshkhali-II CED-III SDB CORE PLAN 2nd Call.
Supplying fitting and fixing street light with 80mm G.I. pipe (4.0m long )and necessary fittings including all cost of materials, light, battery and other equipments and labour charges for fitting as per direction of Engineer-In - charge (LED 1 street light Pv Module 35w Panel solar charging full luight: 8hrs Battery Capacity : 52000mah Battery Nominal voltage : 14.8 V
COMPREHENSIVE MAINTENANCE INCLUDING DAY TO DAY REPAIR LODGED THROUGH ONLINE COMPLAINT MGMT SYSTEM/OFFLINE ORDERS WITH SCOPE OF REPAIR OF LEAKAGE/SEEPAGE IN ANY PART OF THE BLGS, MECHANICAL, ELECTRICAL, SUMMER AND WINTER APPLIANCES, PLUMBING, JOINERY,
Repair / maintenance / servicing to solar water heater system having a capacity 100 to 200 LPD complete with descaling / cleaning to flat plate, collector plate, solar heater water tanks, toughened solar glass panels, welding / breazing to solar tanks, Repair / rectification of leakage in inlet / outlet water tubing GI, checking and repair to electric system, Repair of water make up tank and make the system function cable after repair / servicing and rectification of the fault complete with and including replacement of minor spare parts complete all as specified and as directed.
COMPREHENSIVE MAINTENANCE INCLUDING DAY TO DAY REPAIR LODGED THROUGH ONLINE COMPLAINT MGMT SYSTEM/OFFLINE ORDERS WITH SCOPE OF REPAIR OF LEAKAGE/SEEPAGE IN ANY PART OF THE BLDG, MECHANICAL, ELECTRICAL, SUMMER AND WINTER APPLIANCES, PLUMBING, JOINERY,
Repair / maintenance / servicing to solar water heater system having a capacity 100 to 200 LPD complete with descaling / cleaning to flat plate, collector plate, solar heater water tanks, toughened solar glass panels, welding / breazing to solar tanks, Repair / rectification of leakage in inlet / outlet water tubing GI, checking and repair to electric system, Repair of water make up tank and make the system function cable after repair / servicing and rectification of the fault complete with and including replacement of minor spare parts complete all as specified and as directed.