Loading…
Loading…
1,426 results • Best match
REPAIR/REPLACEMENT AND MAINTENANCE OF STREET LIGHTS SECURITY LIGHTS UNCTION BOX, STREET LIGHT BRACKETS CLAMPS TIMER SWITCHES AND CABLES INCLUDING CONNECTED ITEM OF WORKS OF DRC OTM TRG AREAS MH 146 BDE OTM AREAS AND OTHER OTM AREAS AT AYODHYA CANTT
Supply and fixing in replacement of ALL-in-One Solar LED street light fitting made up with High Efficiency Mono Crystalline Solar PV Module with suitable Wp, lithium Ferro Phosphate Battery with in built BMS technology , High Efficacy LED, MPPT Solar Charge controller and aluminium Extruded body & is specially programmed to automatically control the dimming and brightness of light , which increases the backup time complete of LED Power light capacity 20/25 Watt IP 66 Protection complete all as specified and as directed. Make- Havells ,Philips, Bajaj, Crompton
REPAIR REPLACEMENT OF INTERNAL UNSERVICEABLE POINT WIRING FITTING FIXTURE AND CONNECTED ACCESSORIES WORK IN SECTOR II UNDER AGE EM IV OF GE (SOUTH) BATHINDA AT BATHINDA MIL STN
S&F in replacement thermostat ISI marked stem type 240 Volts, AC supply temp range at least 30 to 75 degree C for geyser/solar water heater system complete all as specified an directed
Construction of infrastructure of Tactical Head Quarter (THQ) at the camp of 13th Bn ITBP at Mangan Distt. of North Sikkim at an altitude of 15010 feet and a distance of 200 Km from Distt. Mangan and 280 Km from Gangtok. Camp connected by road.
Supplying, installation, Testing & Commissioning of the integrated type solar PV lighting system on the existing pole structure, comprising of 30 watt, 6V Mono Passivated Emitter and Rear Contact (PERC) Solar Panel (minimum efficiency 21%), Pulse with modulation (PWM)/Maximum Power point tracking (MPPT) charge Controller in the box with a sleek appearance and a sturdy structure, is weather-proof, and is simple to install, With Lithium- Iron Phosphate Battery (LiFePO4) 3.2Volt (Cell) 30 AH battery, charging time 8- 10 hours, Battery backup time 12 hours (minimum), LED fixture watt 30 watt, Input voltage: 12V DC , Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5,Driver efficiency >85%,THD 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-08, CRI >80 , under voltage and over voltage protection, Electro Magnetic Interference (EMI) Electro Magnetic Compatibility (EMC) As per CISPER 15 A, lenses for beam angle as per Illuminating Engineering Society of North America (IESNA) type I/II/III as per the width of the road and the project requirement, Correlated Colour Temperature (CCT) 5700°K /6000°K (As per American National Standard Institute (ANSI Bin)) , life time (LED,Driver & electrical circuitry) of 50K hours lamp burring hours till the 70 % of initial Lumen maintained as per LM80 extrapolation IES TM-21-11 report, automatic switch on/off, Alliuminium or Acrylonitrile Butadiene Styrene (ABS body), can be installed on a pole or wall. System lumen efficacy >120 lm/Watt output All as per pre approved by Engineer in-charge complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required.(Part 1), for fixtures up to 60 watt. LED light Complete with mounting structure for the battery and accessories and wind storm withstand capacity as per the zone. (Thermal management: heat sink of aluminium housing such that LED junction temperature do'nt rise aboven 90°C) 30 Watt (System lumen efficacy >120 lm/Watt)
CA NO. GE AF NO.1 / GUR-33 / 2026-27 REPAIR TO LEAKAGE/ SEEPAGE SUNKEN FROM WALL,SHAFTS REPAIR WORK AND OTHER CONNECTED WORKS IN AIRMEN MESS, SNCOS MESS, DESC LINE, DSC MD ACCN, MADHUR MILAN, OFFRS MESS AND OFFRS LIVING ACCN AREA OF 13 BRD , 16 BRD
Taking down existing bitumen felt roof tretment including padding,cement mortar bedding,grass, trees treating with chemical and cleaning the surface and removal outside the MOD land as per NGT norms, complete all as specified and directed Note- Taking down earthng strips and solar panel wires from roof and re-fixing on the same position after APP laying is deemed to be inclusive of rate quoted by the contractor
Construction of Faecal Sludge Treatment Plant(FSTP) of Capacity 26 KLD at Godda municipal counciland Operation and Maintenance of FSTP for 5 years
Engineering, Supply Installation, Testing & Commissioning of 21.8kW Solar On Grid System power plant.SOLAR MODULE-545Wp Solar MonoPERC, 144 cells module,SOLAR ON GRID INVERTER-Enviro GTi 24 KT - NG,DC -DCDB 4 In 4 Out with Fuse,AC DISTRIBUTION BOX-1X63A IN/OUT,1C, 4 sqmm Solar DC cable- (Black & Red),INVERTER TO ACDB -4 C X 25 Sq mm, Aluminium Conductor, XLPE Insulated, armoured , 3.5 C X25 Sq mm Al conductor, XLPE insulated, Armoured Cables,EARTHING SYSTEM-FOR STRCUTRE, INVERTER, ACDB-GI Strip 25x5 mm for Module Mounting Structure,1C X 50sqmm, Copper Cable ,EARTHING PIT- Copper Bonded Earth Rods - 3 Mtr + 25 Kg bag Back Fill Compound,LIGHTNING ARRESTOR-Conventional Lightning Protection System ,1C X 70sqmm, Copper Cable ,GI Strip 25x5 mm ,MODULE MOUNTING STRUCTURE-Mono Rail type shed structure,CONDUIT/ CABLE TRAY-HDPE Conduit 40 mm (DC Cable interconnections),NormalPerforated type Cable trays -with Cover 1.2 Pre Galvanised ,MODULE CLEANING ARRANGMENT-Cleaning arrangement accessories & 1 hp mini water pump single phase with water pressure boostinG and INSTALLATION & COMMISSIONING-Net Metering (If Applicable)
Reliability improvement by means of repairs, restoration/ maintenance of signaling assets under the jurisdiction of SSE/Sig/BPB/IC.
Supply of Charge Controller, 110V/60A of 5.76 KWP Solar Power Generating System for IPS battery charging, Make - Mahadev Saur Urja Projects Private Limited or similar.