Loading…
Loading…
1,286 results • Best match
CONSTRUCTION OF SUB-DIVISION OFFICE BUILDING AT FORBESGANJ IN DISTT-ARARIA
Supplying Installation, Testing and Commissioning of on-grid Solar Photovoltaic Power Plant conforming to various applicable standards BIS, IEC, MNRE guidelines, the Central Electricity Authority Regulations and CPWD Specifications as amended up to date, consisting of Mono/Poly Crystalline silicon solar cells module, net metering facility, necessary control, protections, earthing, cabling, mounting structure, junction boxes, power conditioning units, Real time online web interfaced Data Monitoring System, Distribution panels, grid connecting arrangement, conduits, pipes, cable trays and other accessories etc. as required. a) High Energy Efficiency Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730- Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 23% at STC with temperature coefficient of Pmax better than -0.30% per 0C. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Solar Modules shall be designed to operate in relative humidity upto 100% with temperature between -10 0C and +85 0C. Further, each PV module used in any solar power project must have Radio frequency identification tag with information such as name of manufacturer, month and year of manufacturing, country of origin (separately for Solar cell and module), I-V curve, Unique Serial No and Model No of the module, Wattage, Im, Vm and FF, name of test lab issuing IEC certificate.
SPECIAL REPAIR TO CERTAIN ROADS NEAR OFFRS SINGLE LIVING ACCN , 2 GARH RIF AND PATH FROM GATE NO 01 OF 52 MED REGT TO TOWARD AMN PI AT MILITARY STATION BHUJ UNDER GE (A) BHUJ
Supply and fix solar cat eye aluminium alloy shall (100% water proofing design according to 65) of size 125mm x 125mm x 25mm (shank 65mm) of high efficiency Mono rystafie solar panel 2.4V/ 0.3 Watt, one NI-ed rechargeable battery (1.2V/ 1600 MA) consisting of six super bright LED with 10,000 mcd to 18,000 mcd completed as per manufacturers instructions etc. all as specified and directed with PAMA striplens reflector of model No. DA 972.0 fixed with and incl MS stud of suitable size as per manufactures instructions.
Construction of Type A Flat at Fisheries Campus Doranda, Ranchi
Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 500 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.
Supplying Electrical Materials And Repair Maintenance Services At. Grampanchayat Khalumbre Tal Khed Dist Pune
75 W Solar Panel
Design, Supply, Installation, Testing and commissioning of 2MWp, 415 V grid interactive solar PV systems on roof tops of PFFF buildings along with 5 years of Annual comprehensive maintenance at Nuclear Fuel Complex (KOTA), Rawatbhata, Rajasthan
Design, engineering, supply, installation, testing and commissioning of grid tied 2MWp solar PV system with required TOPCON Bifacial Solar PV panels, solar mounting array structure, String monitoring, solar cables, inverters, necessary cabling , plant monitoring system (SCADA) , lightning protection, surge protection, earthing system for array yard, measuring equipment for performance monitoring, piping for water cleaning of solar modules, illumination of array yard, housing for inverters and all other accessories as deemed to be necessary and complete as per attached technical specification to complete the work in all respects on the rooftop of PFFF building at NFC Kota
REPAIR / REPLACEMENT OF STREET LIGHTS, CABLES AND CONNECTED ACCESSORIES OF 17 DOGRA AND ARTY CENTRE UNDER GE GOLCONDA
supply and fix 40 W solar street light is made with high efficiency mono crystalline solar PV module ,lithium ferro phosphate battery with in built BMS technology high efficiency LED MPPT solar charge and AL extruded body &is special performed to automatically control the dimming and brightness of light complete all as specified and directed.