Loading…
Loading…
1,287 results • Best match
REPAIRS TO CERTAIN INTERNAL MAIN ROADS and ROAD FURNITURE OF AREA IV AND AREA V UNDER AGE B/R (WEST) UNDER GE(WEST) COLABA MUMBAI
Supplying and fixing in repair LED powered solar road studs of size not less than 110 mm X 110 mm X 25 mm (with shank height not less than 50mm) made of weather resistance aluminium alloy and poly carbonate material electronically welded micro- prismatic lens with abrasion resistant coating. Protection shall conform to IP65 in accordance with IS: 12063-1987 Category 2 for protection against water ingress. Mono-Crystalline Solar Panel 2.4 V / 0.3 Watt. One Ni-Mh or NI-cd Rechargeable Battery (1.2V / 1600 MA). The cats eye shall support a load of approx 10 TON weight. The slope of retro- reflective surface shall be 35 ± 5 degress to base. The reflective panels on both sides with at least 12 cm of reflective area up each side. The stud shall provide a viewing distance of not less than 800m. The studs shall be flushed onto the to the Road surface and fixed using the adhesive conforming to IS, as per procedure recommended by the manufacturer complete and as per direction of Engineer-in-charge. Make: Dark eye / 3M or equivalent
Construction of Residential Portion in New District Jail Fatehabad (1 No. Superintendent Jail Residence, 6 Nos 1900 Sqft Houses, 24 Nos 800 Sqft Houses, 72 Houses 650 Sqft Houses, 12 Nos 550 Sqft Houses, Warder Hostel and 9 feet height Boundary wall)
[32.70.2]Supply Installation testing commissioning of Solar Photovoltaic grid connected roof top Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- (a) Solar Photovoltaic Module manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. (b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz plus /- 2.5 Hz, output voltage suitable to generate AC (c) Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degrees C. The PCU shall adjust the voltage and frequency level to suit grid frequency (d) Data Monitoring System complete with accessories. (e) Fixing of Array junction box and Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. (f) Lightning and surge voltage protection. (g) Connections and Interconnections by supplying and fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying and fixing of necessary channel/conduit lugs and other accessories etc. as required. 2. Above 10 kWp and up to 100 Kwp [Through Rate]
Road Safety Improvement Works for 2 corridors covering 14_10km in Chennai city SH1 Chennai Ennore Expressway Road SH48B Taramani Link Road
Proving and fixing Solar powered Traffic Blinkers of 30cm dia with Polycarbonate Dome 5mm Red of Led 150 Nos. iri each Red Blinkers Light - 1 No. with Red / White / Blue Led Blinkers Delineator Solar Panel : 12v 50w Solar Panel — 1 No. 12v 18 AH Battery -1 No. with Box, Solar Circuit Controller Board Box. Straight Pole : MS Pole 3” dia 2.5mm thick 18 Feet height pole (1 No.) with 2 Feet under ground pole foundation, pole painting including transportationcharges, installation charges etc., complete as per standard specification.
Road Safety Improvement Works for 1 corridor covering 10_60km in Chennai city (SH 10_9 Pallavaram Thoraipakkam Road)
Proving and fixing Solar powered Traffic Blinkers of 30cm dia with Polycarbonate Dome 5mm Red of Led 150 Nos. iri each Red Blinkers Light - 1 No. with Red / White / Blue Led Blinkers Delineator Solar Panel : 12v 50w Solar Panel — 1 No. 12v 18 AH Battery -1 No. with Box, Solar Circuit Controller Board Box. Straight Pole : MS Pole 3” dia 2.5mm thick 18 Feet height pole (1 No.) with 2 Feet under ground pole foundation, pole painting including transportationcharges, installation charges etc., complete as per standard specification.
Setting up of Flatted Factory Complex at Chabua, Dist. Dibrugarh
ON GRID SOLAR POWER: Design, Supply, Installation, Testing and commissioning of 20 kVA Solar On grid complete pacakage plant with required Meter. Solar Panel : Polycrystalline solar panel Panel structure: Included Solar Panel Watt: Min 330 Wp On grid PCU/: Included with min 2 years of warranty With protection of Short circuit current and earthfault AC Cable and DC cable : 50 meter Included All accessories included : Lugs , MC 4 c AC Cable And DC cable :50 meter Included All accessories included: Lugs,MC4 connectors etc
PROVN OF JCOs MD ACCN FOR ALL UNITS LOCATED INSIDE DHOLEWAL MIL STN
Design, supply, erection, installation, testing and commissioning of ON GRID type Roof Top Solar Photo Voltaic Power Plant system of 4.0 KW capacity complete incl comprising of DCR Solar Photo Voltaic Modules (cap as specified under in reqd qty to make full cap 4.0 KWp), Inverters/PCUs, Module mounting structure, Net meter (as applicable) , Generation meter, Array Junction boxes, DC junction/ distribution boxes, AC junction/ distribution boxes, Solar grade DC copper cables, AC cables, Lightning arrestor, surge arrestor, Earthings, civil RCC/ PCC/ earth work, Ladders, below mentioned items, BOS, accessories complete incl miscellaneous items reqd for satisfactory functioning of roof top solar power plant suitable to be installed. (For 04 JCO Md Accn Dholewal-