Loading…
Loading…
1,291 results • Best match
Construction of Type A Flat at Fisheries Campus Doranda, Ranchi
Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 500 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.
Supplying Electrical Materials And Repair Maintenance Services At. Grampanchayat Khalumbre Tal Khed Dist Pune
75 W Solar Panel
Design, Supply, Installation, Testing and commissioning of 2MWp, 415 V grid interactive solar PV systems on roof tops of PFFF buildings along with 5 years of Annual comprehensive maintenance at Nuclear Fuel Complex (KOTA), Rawatbhata, Rajasthan
Design, engineering, supply, installation, testing and commissioning of grid tied 2MWp solar PV system with required TOPCON Bifacial Solar PV panels, solar mounting array structure, String monitoring, solar cables, inverters, necessary cabling , plant monitoring system (SCADA) , lightning protection, surge protection, earthing system for array yard, measuring equipment for performance monitoring, piping for water cleaning of solar modules, illumination of array yard, housing for inverters and all other accessories as deemed to be necessary and complete as per attached technical specification to complete the work in all respects on the rooftop of PFFF building at NFC Kota
REPAIR / REPLACEMENT OF STREET LIGHTS, CABLES AND CONNECTED ACCESSORIES OF 17 DOGRA AND ARTY CENTRE UNDER GE GOLCONDA
supply and fix 40 W solar street light is made with high efficiency mono crystalline solar PV module ,lithium ferro phosphate battery with in built BMS technology high efficiency LED MPPT solar charge and AL extruded body &is special performed to automatically control the dimming and brightness of light complete all as specified and directed.
PREVENTIVE MAINTENANCE OF AREA LIGHTING SYSTEM INCLUDING CONNECTED WORKS AT SOUTH CAMP MAP AREA 4 AFSR NEW PROJECT AND ALLIED AREA AT AF STN BAMRAULI UNDER GE AF BAMRAULI
Supply and fixing in replacement of Lithium base Energy efficient integrated Solar street light of 32 watt in single FRP body duly polyurethane coating (Camouflage color), encases with monocrystalline solar PV panel of 65-67Wp,lithium battery 11.1/12.8V,33.0 AH with inbuilt BMS,IP 65, High brightness W-LED(160-180lm/watt) lamp with Aluminium reflector for better light distribution ,CRI>70, color temp 5700K-6500K Microcontroller based charge controller cum driver,automaticdimming function(First 04 hrs at full brightness & rest of the time at lower light level with PIR motion sensor), Dusk to dawn operation,suitable to working temp (-) 10C to (+) 55C ,weight not more thatn 16-18 Kg with adjustable MS clamp suitable for pole/wall mounting etc, complete as reequired.Make: AXON/HAVELLS/PHILLIPS as approved. Protections: Short circuit, overload,Reserve polarity and battery protection.Firm should provide vital parametres Test report from NABL accredited lab and should be of made in India with CE & ROHS complaint. (Excavation & earth work shall be measured separately)
PREVENTIVE MAINTENANCE OF AREA LIGHTING SYSTEM INCLUDING CONNECTED WORKS AT HQ CAC HAPPY HOME MES CIVILIAN MD ACCN MD ACCN AT NORTH CAMP AND ALLIED AREA AT AF STN BAMRAULI UNDER GE AF BAMRAULI
Supply and fixing in replacement of Lithium base Energy efficient integrated Solar street light of 32 watt in single FRP body duly polyurethane coating (Camouflage color), encases with monocrystalline solar PV panel of 65-67Wp,lithium battery 11.1/12.8V,33.0 AH with inbuilt BMS,IP 65, High brightness W-LED(160-180lm/watt) lamp with Aluminium reflector for better light distribution ,CRI>70, color temp 5700K-6500K Microcontroller based charge controller cum driver,automaticdimming function(First 04 hrs at full brightness & rest of the time at lower light level with PIR motion sensor), Dusk to dawn operation,suitable to working temp (-) 10C to (+) 55C ,weight not more thatn 16-18 Kg with adjustable MS clamp suitable for pole/wall mounting etc, complete as reequired.Make: AXON/HAVELLS/PHILLIPS as approved. Protections: Short circuit, overload,Reserve polarity and battery protection.Firm should provide vital parametres Test report from NABL accredited lab and should be of made in India with CE & ROHS complaint. (Excavation & earth work shall be measured separately)