Loading…
Loading…
1,291 results • Best match
Studio Apartment (G+4) and Principal-cum-Lecturar Residence (G+4) at Govt. Polytechnic, Purnea for the year 2025-26 (Re Tender)
64 DSR Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specification as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- (a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, Conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2, Solar Photovoltaic Module conversion efficiency shall not be less than 16.5% PV modules used in solar power plants/systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. (b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. (c) Data Monitoring System complete with accessories. (d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. (e) Lightning and surge voltage protection. (f) Connections and interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kv grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. 13.00 KWp 64,332.00 836,316.00
Electrical work in connection with Interlocking of LC gate no. 19 KM 707.297 between CNDB-MRSH.
S.E.T.C. of 3 KWp ON-GRID Solar PVSystem / Plant consisting solar PV panel and Solar ON-GRID Inverter of similar capacity (THD3%) with inter connecting wires / cables upto solar ON GRID inverter, proper base plate, canopy box 21 to house Inverter and necessary accessories i.e. ACDB/ DCDB, MCB etc. wiring up to solar Inverter in casing and capping, display board, sign board, two distinct earthing, lightning arrester, liaisoning charges, remote monitoring system with maintaining card/chip for 5 years including net charges for RMS system, complete up to net meter installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenance contract as per specification.
Annual Maintenance including Incident Management of Thanjavur - Trichy section from Km 80/000 to Km 136/490 of NH-83 in the State of Tamil Nadu on Item Rate Basis
Supplying and erecting red /yellow unbreakable polycarbonate body Solar Blinker 300mm dia. LED lamp confirming to IRC:93 and IS:7537. It shall have Light Emitting Diode (LED) — HI Bright technology {Compliant to EN12368 or equivalent BIS standard). The Signal Switching shall be Solid State, with Opto-isolation. The Automatic operation mode shall have functional flashing rate available at 50% Duty Cycle - 50 or 60 Flashes/minutes. The Electrical Power Supply shall be solar based 12 VDC operating at Ambient Temperature 0° to 55"C. The solar power system shall have in-built charge Controller - Low/High cut out, Solar SPV Module - 60 Watts, maintenance Free battery (60AH) (having back up for operating blinder for 72 Hrs in absence of Sun or during rainy or foggy days. The Solar System shall be housed in a weatherproof pole mounting cabinet with clamp and mounting accessories. The Solar Blanker shall be supported on GI circular pipe 80 NB, 3.2 mm thickness confirming to IS 1239, 3m above the Finish Road level. GI circular pipe shall be firmly fixed to the ground by means of properly designed foundation with M 25 grade cement concrete 45 cm x 45 cm x 45 cm x 60, 60 cm below ground level as per approved drawing. Alternate white and yellow bands (Minimum four bands) of Type XI retro-reflective sheeting shall be pasted @ 05.m c/c starting from a height of 0.5 m above the finish road level.
Miyawaki Plantation 1 No. and Pasture Development work 2 No under PMKSY-2.0 , XEn WDSC Block Khandela, Sikar
Supply, Installation, Testing and Commissioning of different different capacity Solar Powered Water Pumps with complete assembly of Solar Modules, controller, Solar motors, including transportation, loweing and fixing with the SPV module, controller and providing pipe connections on suction and delivery sides, of approved make and specifications laid down and updated time to time by MNRE, complete in all respect, Surface Pumps (Non Bsr Item ) 2 HP
SHORT TERM MAINTENANCE CONTRACT STMC FOR KM 92/400 TO 127/350 OF NH-248A (HANUMAN CIRCLE TO NAUGAON SECTION) IN THE STATE OF RAJASTHAN (JOB NO. RW/JAI/STMC/ 2026-27/NH-248A/01)
SITC of Crystal control Road warning Blinker system with solar panel module with 300mm LED Module of minimum 190 Nos., Blinker Units, Charging circuit, suitable SMF Rechargeable Battery (12 Volt,), including wiring, connections etc. complete in all respect
Construction of Wellness Centre along with High End Fountain at Nagrota Bagwan, District Kangra, Himachal Pradesh
Solar Panel System:- SITC of 25KW Solar Power Plant Havells make including Solar PV Modules 540Wp (mono type): 47 Nos, Solar Grid Tie Inverter 25KW: 1 Nos., DCDB (DC Safety unit -Supply of DCDB (DC- Safety unit) with Fuses & DC SPD class-1 Nos, AC Distribution Box: Main AC Distribution Box complete with 1 Nos. Class I + II Surge Protective Device with CT & Multifunction Meter & required MCCB/MCB, Cables as per site: From PV Module To LT Panel: 1 C X 4 / 6 Sq mm Solar cable (Module to DCDB), 3.5 C X 6 Sq mm cu wire (ACDB to LT Panel), Required Earthing System: Module Earthing, Inverter & LA earthing, Conduits / Cable Tray: Conduit Pipes, Cable trays, RJ-45 connector as per the site condition, complete in all respect, including all accessory, mounting structure of suitable size including carriage of materials up to all lead and lift and as per direction of Engineer in charge. As required (Havells/Luminous/Tata or equivalent.