Loading…
Loading…
1,464 results • Best match
REPAIR AND MAINTENANCE OF ROAD AND PATH INCLUDING ROAD FURNITURE AT KHALSAR UNDER GE 873 EWS
Supply and fix in repair solar cat eye aluminum alloy (100% water proofing design according to 65) of size 125mm x 125mm x 25mm (shank 65mm) of high efficiency Mono rystafie solar panel 2.4V/ 0.3 watt one NI-ed rechargeable battery (1.2V/ 1600MA) consisting of super bright LED with 10,000 to 18,000 mcd complete as per manufacturer's instructions all as specified and/ or as directed by Engr-in-Charge.
REPAIR TO ROAD AND ROAD SIDE FURNITURE AT AF STN JODHPUR UNDER AOR OF AGE B/R-I, GE (AF) NO 2 JODHPUR.
Supply and fix solar cat eye aluminum alloy shall (100% water proofing design according to 65) of size 125mm x 125mm x 25mm (shank 65mm) of high efficiency Mono rystafie solar panel 2.4V/0.3 watt one NI-ed rechargeable battery (1.2V/ 1600MA) consisting of super bright LED with 10,000 to 18,000 mcd completed as per manufactures instructions etc. all as specified and directed.
CA NO.CWE BLY/GE (W)/47 OF 2026- 2027SPECIAL REPAIRS TO ROAD FOOTPATH AND ALLIED WORKS IN JAT REGT CENTRE (JRC) AND PB MARG UNDER GE (WEST) BAREILLY
S&F two way reflective Solar road studs (100% water proofing design according to IP-65) of dimensions 125mm x 125mm x 25mm (shank 65 mm) of high efficiency mono-crystalline solar panel 2.4V/0.30 Watt, one Ni-Mh of Ni-cd rechargeable battery (1.2V /1600MA), six super bright LEDs with 10000 to 18000 mcd (Millicandela) , view distance upto 1000 meters, flash rate 2 Hz and bearable weight of solar studs (10 Tone approx) with impact resistance aluminium alloy body with yellow/ red/ white/ green reflective panels and fixing the same on road surface by applying approximately 100 gm epoxy mixture and placing the cats eye without applying excessive pressure and fixed with 12mm dia and 120mm long zinc plated steel nail at the centre of cats eye complete all as specified and directed.
CONSTRUCTION OF GOVT SR. SEC. SCHOOL AT BAJWARA, DISTRICT HOSHIARPUR (PUNJAB)
Supply, Installation, testing & Commissioing of Grid interactive PV System Solar Power Plant (i.e connected to utility grid) of Minimumcapacity including required quantities of SPV modules (High power density bifacial monocrystalline solar modules with a capacity of +400 watts) formed into arrays, their mounting arrangement, Power conditioning units (i.e String Solar Inverter with 2Nos. GI Chemical earthing with suitable size GI strip upto string inverter and AC & DC distribution panel), required DC & AC distribution panels with surge protection units, cabling from terrace to main distribution board through Cable tray, Bi Directional Energy Meter, Provision of Lightening Arrestor & 2 Nos. GI chemical earthing with suitable size GI strip upto Lightning arrestor, Hot dip galvanized MS Mounting Structures (1No. GI Chemical earthing with suitable size GI strip upto mounting structure) should be designed to withstand the speed for the wind Zone of the location (150 Km/hr-170 Km/hr) Complete in all respect with transportaion, fabrication, labour & Civil Work etc. Features :- 1. Solar PV Module warranty 25 Years & certified under IS/IEC 61730 I & II IS/IEC 61701 & IS/EC 14286 2. Power Conditioning unit (string solar inverter) & certified under IEC/EN 62109-1, IEC/EN 62109-2, EN 61000-6-2, EN 61000-6-3, IEC 61683, EN 50530, IEC 60068-2-1, 2, 14, 30, EN 60529 3. Structure 25 Years service life with AMC & certified under IS 2062 2011 4. Complete Plant insurance for the period of 5 Years (Excluding Theft of the Material) 5. Annual Maintenance contract for the period of 10 Years Conditions: # The Plant will be installed as per MNRE and GOI guidelines and specifications. (Detail of material as per Annexure-I attached) #The work will got done from approved MNRE (Misitry of New and Renewable Energy)/ PEDA (Punjab Energy Development Agency) contractor/PWD enlisted contractor subject to the condition that PWD enlisted contractor will get work done from /MNRE/PEDA approved contractor. #The capacity of solar power plant my increase or decrees as availability of site it can also be totally removed from executive end The Rate are inclusive of all taxes including GST, Bi-directional meter testing charges uni-directional meter cost and PSPCL connection Charges
Civil, Sanitary and Water supply and Electrical Work
Supplying, Installation, Testing and Commissioning of 5 KVA Off Grid Solar Power Plant inclusive of lighting protection, Power Conditioning Unit, Solar Panels,ACDB-DCDB Converters as per direction of Engineer-In-Charge
AMRUT 2.0- Augmentation of WSS to Kollam Corporation- Design and construction of 20LL capacity OHSR at Jala Bhavan Compound, Kollam
OD276374/2025-2026:Supply installation All type of testing, trial run and commissioning of solar on grid plant with advanced Mono Perc Half Cut Solar panels, Structures to mount panels, DC cables and connectors DC junction Box, Inverters . AC junction BoxLink,,solar meter with Box, AC cables, Link/CB, TPN Box, Net Meter with approval of KSEB approval and all other electrical and mechanical accessories complete as per the direction of departmental officers and in accordance with Inspectorate standards. All paperwork, statutory fees and allied works with the Electrical inspectorate and KSEB Limited for the approval and to be got approved by Electrical Inspectorate and KSEB Limited