Loading…
Loading…
3,877 results • Best match
REPAIR/MAINT OF LT UG CABLES, SWITCH GEARS, BUS BARS, LT PANELS DISTRIBUTION SYSTEMS, APFC PANELS ETC AND CONNECTED WORKS IN TECH AREA AF STN GWALIOR
Supply and fixing in replacement for energy saving environment friendly, long life exclusive innovative die cast aluminium IP-65 street light 70 Watt LED 6000K with high power LEDS as light source complete including suitable fixing arrangement on pole, pillar, wall with appropriate fasteners, nut, bolts, clamps and making connection with three core copper conductor cable not less than 1.5 sqmm complete all as specified and directed.
Canal Water Based Water Supply Project for Construction of 3.0 MLD Water Treatment Plant (WTP) and other related works incluidng 5 year O and M (Part 2) at Mudki Distt Ferozepur Punjab Under AMRUT 2.0 (E Tender 90)
RUIDP ISOR 2023, 67.12 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) 10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current 750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
PROVN OF CERTAIN OR MARRIED ACCOMMODATION AT OP HILL RAIWALA
Supply and fixing in repair 35 W LED street lights, IP 66 & IK07 protected, housing made of powder coated single piece pressure die cast aluminium with heat dissipation housing with toughened glass cover and secondary lens on each LED & should oe SMD type. The System Luminaire efficacy >= 120 Im/wat: with High power LEDs is to be used and potted driver must be potted & has a unicue BISR number with input voltage 120 V to 270 V AC with High voltage Cut off @ >= 300 V AC and auto resetting safety Input Frequency 50 Hz ± 3 % Power factor > 0 95 drıver Efficiency > 85%, THD (1) 10%, humidity 10% to 90 % RH, CRI >70, Working Temp -10 C to 50 C The Luminaire shall be BIS certified and T.C certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintaned and CCT 5700 K+335K. Surge shall be min>= 4 KV internal and min 10 KV external. AC protection complete all as specified and directed.
CONSTRUCTING 11KV ABC LINE FROM EDATHALA S/S TO CHOONDY JN. UNDER ELECTRICAL SECTION ALUVA TOWN
Dismantling one ordinary street light/CFL/LED fitting from existing pole and refitting the same on newly erected pole including disconnecting and reconnecting wires.
ARM of CTF HQ FHQ Buildings for the year 2024 -25 at NSG Camp Manesar Gurugram (SH Balance Work)
Supply, installation, testing and commissioning of 25 watts LED-based post top luminaires, IP 65, with Die-cast aluminium spigot housing and complete with diffuser, LED module, electronic driver and all other accessories, having minimum system luminous efficacy of 95 lm/W, on existing street light pole/gate including connection etc. as required. Make :CORAL (Opal) or RUBY (Clear) of Havells similar in Philips / Havells/ Wipro/ Bajaj
Proposed Construction of (G Plus 2) storied 50 Bedded Critical Care Block at Barasat Government Medical College and Hospital, North 24 Parganas District -- External E.I. Work (Sub-station Work and Compound Light).
Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminum body finish with corrosion resistance fasteners (SS hardware) & silicon gasket for proper sealing with driver as per the requirement with Driver efficiency >80%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range 0o to 50o C and working RH 10% - 90%, internal surge protection of 5 KV internal and external SPD min. 10 KV, L,N,E as per IEC 61000-4-5. The driver rated output wattage should be 10% to 15% higher than lamp rating and at least 2 driver for 200W & above and Driver efficiency >85%, THD 10% as per IEC 61000-3-2 , P. F.≥0.9, IP- 66, IK-08 specified below, CRI >70, under voltage and over voltage protection, high efficiency lens with type II/III distribution as required with UV stabilized optical lens, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours (Life projection shall be calculated as per TM-21 methodology) and 70% of initial Lumen maintained till life ends. CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect and LED Chips of SMD mid to high-power (2.5 to 4 watt for 200 watt and above, as per required (LM-80 tested) and necessary inter-connections with 1.5 sq mm FR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM comprehensive on-site warranty against manufacturing defects including driver and LED module. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. System lumen efficacy shall be as below: [Make:Signify/Crompton/Wipro] System lumen efficacy ≥135 lm/Watt 100 Watt