Loading…
Loading…
3,781 results • Best match
Upgradation of PWD Dak Bunglow Manjakote (Under NFB)
Supplying, installation, Testing & Commissioning of 100 watt Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5,n Driver efficiency >85%,THD 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) 5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy ≥120 135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
CA NO CE CHZ PAT T 19 2025 26 PROVN OF OR MARRIED ACCN AT NABHA MILITARY STATION
Outdoor LT outdoor feeder pillar panel kiosk type made out of CRCA sheet 3.15 mm thick vermin proof factory made, with aluminium. Bus bar of capacity 400 Amps for 3 phase and neutral with necessary angle iron 50 x 50 x 6 mm support frame including two coats powder. Painting over a coat of red oxide primer and grout in PCC and fixed with legs 30 cm below ground and 60 cm above ground, both front & back opening provision. (Incoming Supply from DG Set to be kept near Pump House). (a) INCOMING : (i) MCCB 250 A, 415 V, 4 pole with over load short circuit protection, breaking capacity 35 KA Multi function meter for measuring V,A,F,KW,KVA including CTs of suitable capacity-01 Nos. (ii) Indicator lamps RYB LED type(Set of Three)-01 No. (b) OUTGOING : (i) MCCB 100 A, 415 V, 4 pole with over load short circuit protection, breaking capacity 16 KA-02 Nos (ii) MCCB 32 A, 415 V, 4 pole with over load short circuit protection, breaking capacity 16 KA-01 No for Street Light Timer Panel. (iii) DOL starter with single phase protection feature, ON/OFF, indication lamp, contractors, ammeter with suitable C.T’s sufficient Nos of potential free spare contacts, etc. suitable for 15 HP motor-02 Nos (iv) MCB TP, 6-32 Amp 3 Pole-02 Nos (v) MCB SPN 6-32 Amps-01 No (vi) Provision of Space to Accomodate MCCB 4 pole 100 A-01 No & MCB TP 40 A-01 No. (vii) Wiring of above accessory with suitable size of copper conductor cable
Electrical work in c/w Augmentation of Service building for SSE(C&W) office in lieu of old building for C&W Coaching Depot, FZR, Electrical work in c/w General Watering Arrangements at FKA, MOGA & LNK of Firozpur Division, Electrical work in c/w Provision of 15 bedded male barrack at Attari and Electrical work in c/w Improvement to washing line no. 4 and Sick line / Ac pit at Amritsar Railway Station in the section of ADEN-I/ASR.
Description:- Supply and erection of minimum 45 W LED Street light fitting operating voltage single phase 230 volts AC, 50Hz complete with all accessories as per CEE/NR Specification.
Construction of Pre fabricated Hut With Toilet at Sheep Breeding Farm Balnoi
Complete electrification and ilumination along with accessories which includes mainly copper wire 1mm,copper wire 1.5mm,copper wire 2.5mm, PVC batten, PVC box + 12 modular+sheet -01 no each, PVC box + 08 modular+sheet -03 no each, PVC box + 03modular+sheet -05 no each, socket 6amps-05 no, switches 6amp-35no.,socket 16amps-05 no, switches 16amp-05no., Fan regulator 02 no. power indicator , Blank switch ., LED Concealed Light 5W-11 no., PVC junction box 4 way -12 no., GI clamp, PVC gatti & screws, service line 16 mm aluminium, MCB box double door 08 way -01 no., MCB 16 amp-06 no., SPN 63 amps-01 no, Button holder-08 no, ceiling fan -02 no., exhaust fan -02 nos. PVC tape rolls, LED street light 30W -04 nos. complete earthing at site by way of earth excavation of size 3'x3'x6' and insertion of earthing rod 6' along with filling of earth and coal+salt mixture in layers as per req. quantity. connecting of earthing rod to the MCB box by way of p/f of copper wire 10mm-20 mtrs along with nuts and bolts as required and covering the pit with P.C.C. (1:3:6) and main hole 9"x9"-01 no. Job includes cost of material, labour charges and all kind of taxes.
Electrical works connection to Provision of New Tower wagon shed at Madhosingh.
VARANASI DIVISION-ELECTRICAL/NORTH EASTERN RLY Description:- Supply, installation, testing and commissioning of street light LED based fitting rated
LAC-ADS-2022-23-Kunnathur LAC -Sri.Kovoor Kunjumon MLA - Construction of new Building for PHC Puthanambalam ---General Electrical Work
90.15.4.1:Supply Conveyance, installation, testing and commissioning of 20W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)