Loading…
Loading…
3,737 results • Best match
Co GOs living accommodation including kitchen toilet and guest house and ii ORS living accommodation along with kitchen and dining hall at Surwasamba BOP of 55th Bn ITBP Rangamati Assam.
Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD 10% as per IEC 61000-3-2 , P. F.≥0.95, IP66,IK-10, CRI >80, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) 5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). (a) 45 watt
REPAIR REPLACEMENT OF OLD DAMAGED CGI SHEETS ACC SHEETS REPAIR TO RCC SLAB FALSE CEILING AND INTERNAL EM FITTING FIXTURES IN CERTAIN BLDGS IN AOR OF AGE BR DETT-III OF GE 862 EWS
S&F in replacement of LED bldg street light fitting 30 watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, bracket etc including connection, complete all as specified and directed.
Combined Package for WorkA -Augmentation of 2x20MVA 66/11kV Power T/fs by 2x31.5 MVA, 66/11kV Power T/fs at 66/11kV Bannerghatta Road Sub-Station in Bengaluru South Taluk, Bengaluru Urban District.WorkB- Augmentation of 2x20MVA, 66/11kV Power T/fs by 2x31.5 MVA, 66/11kV Power T/fs at 66/11kV Jigani Sub-Station in Anekal Taluk, Bengaluru Urban District.WorkC-Augmentation of existing 2x12.5MVA, 66/11kV Power T/fs by 2x31.5 MVA, 66/11kV Power T/fs at 66/11kV Chokkasandra Sub-Station in Anekal Taluk, Bengaluru Urban District on Partial Turnkey Basis
SS49 b) Supply of LED street light luminaire with pressure die cast aluminium housing body for optimal thermal dissapation.Lamp compartment comprising of antiglareclear diffuser with injection moulded polycarbonate material LED streetlight 200W Nos. 12.00 0.00 12.00
Providing Technical Assistance for Electrical Engineering works at ESD, IGCAR, Kalpakkam for 2026-27.
Recording of Hourly Reading of Electrical Parameters, monthly energy readings of 33kV / 11kV / 6.6kV / 415V system switch board for testing / analysis purposes, Assisting departmental staff for the day to day highly skilled operational activities of various substations, Attending fuse of calls pertaining to street lighting, Building lighting & power complaints in IGCAR campus during after office hours and holidays, changeover operations carried out to restore the supply system during fault trippings. Note: 1) The High skilled person having qualification, ITI(Electrician)/DEEE qualified electrician having “B”or “C” Electrical license and shall have minimum 2 years of experience in Operation and maintenance of substations. 2) Necessary register for recording the parameters will be provided by the Department free of cost. 3) 8 Hours shift is considered as one operation. 4) Shift includes Round the clock operation.
Construction of New Building of Sub Centres and Group Centres under intensive Cattle Development Programme at Padardi, Dist- Sabarkantha
152 Supplying and erecting LED street light / Flood light 6.00 Nos. 3345.12
SPECIAL REPAIR OF OR MD ACCN FROM P-335 TO P-342 AT JOGINDER SINGH ENCLAVE NEW CANTT PRAYAGRAJ
Supply and fixing LED street light fitting 35 Watt 230 Volts AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including bracket for street light made out of 40mm bore GI pipe medium grade not less than 1.2 mtr length bent at 120 degree to shape fixed on pole/wall with and including 50 x 6mm FI clamps = 02 Nos with nut bolts, washers including painting of clamps with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.