Loading…
Loading…
3,757 results • Best match
1) Construction of Toilet and Bath Rooms at SLC Kolamguda (V) of Gadiguda (M) in Adilabad District, 2) Construction of Toilets and Bath Rooms at STBH Bheempur (V) of Narnoor (M) in Adilabad District ( Reserved for SC Community as per GO 59, Dt:21.5.2018)
Supply and transportation of 100W LED Street light Body made of high grade pressure die cast Aluminium alloy with corrosion resistant powder coat, having protective toughened glass cover/ temperature protective custom molded polycarbonate diffuser, Thermal shock and impact resistant IK07 fixed to the housing by SS screws Suitable lense on LEDs, Less Glare, IP 66 (Silicon gasket ensures Optical & Electrical compartments are IP 66)protected, wide operating voltage range,P.F > 0.90, System having efficacy >120 lumens / watt, with Ingress protection IP66, BIS approved Potted driver, Driver surge protection >10KV, THD15%, CCT: 3000-6500K as desired by the department and as per IS, CRI>70, Inbuilt Electrical protections like Over voltage, short circuit, Over load, Open Circuit, Miswiring, etc complete with BIS certification with 5 years warranty. The contractor has to furnish the manufacturer warranty letter, LM 79 and LM 80 certificates. LUMINAIRE MAKE: PHILIPS / OSRAM / CROMPTON / BAJAJ / Surya / Ecolink / Wipro / Jaquar / Eveready / Halonix Keselec/HAVELLS/POLYCAB / SURYA
WELCOME MAINTENANCE INCLUDING INTERNAL SMART PAINTING TO OMQ ,BT AREA AND MES ACCN INCLUDING E/M SERVICES AT AFS AMLA
Fixing only in repair LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection and necessary mounting arrangements alongwith provision of 0.75 sqmm three core copper conductor cable multi stranded from ceiling rose to light fitting including suitable dia GI pipe medium grade bracket 0.75 mtr long bend to required shape with clamps, nut, bolts complete all as specified and directed.
TENDER FOR ELECTRIFICATION, REPLACEMENT, REPAIRING WORK FOR SURENDRANAGAR CIRCLE OFFICE AND RSO OFFICE .
11 Providing and fixing 30W LED Street light bulkhead (CGL 30 Nos 2678.00
SPL REPAIR TO BLDG NO T-103 FOR HQ 4 EW BDE AT BMC UNDER GE (C) KOLKATA
S&F LED fittings with lamps 35 watts for bldg security light IP-66 power coated pressure die cast aluminium compact high power LED street light with compact size and rough design 32mm GI bend including taking down one as specified and directed
REPAIRS / MAINTENANCE / REPLACEMENT OF LT PANELS, UG CABLES, SWITCH GEARS AT DOMESTIC AREA UNDER GE (AF) KALAIKUNDA
Supply, installation, testing and commissioning, LT panel board, 415 Volts, 4 wire, AC 50 Hz, factroy made, outdoor pedestal type, double door type (openable front and back), weather and vermin proof, fabricated of 3.15 mm thick CRCA sheet, confirming to Latest IS 8623(CPRI Approved), powder coated RAL-7032 with seven tank Pre-treatment and outside locking arrangement, two earth terminal, and cable glands for all incoming and outgoing cables including grouting of LT panel 45cm above ground level by providing 90cm long iron angle of size 50x50x6mm welded on all four corners embeded in PCC 1:2:4 using 20mm stone aggregate upto 45cm grouted in ground and 15cm above ground for coping complete all as specified and directed by Engr-in-charge including the following components :- (Make of MCCBs: Lauritz Knudsen/Hager/ABB) (a ) Four Nos of aluminum bus bars of high conductivity, 3 Nos for phase (RYB) and one No for neutral of current rating 400 Amps mounted on porcelain support. ( b) Incoming: MCCB 250 Amps, four pole 415 volts, thermal & magnetic release adjustable type with breaking capacity 36 KA (luc= Ics at 100%) with spreader links, etc -1 Nos. (c) Outgoing: MCCB 63 Amps, four pole 415 volts, thermal & magnetic release adjustable type with breaking capacity 25 KA (luc = at 100%) with spreader links, etc -12 Nos.(d) street light timer assembly, three phase, maximum load 12 kw, wired with digital timer switch, contactor TP rating 65 Amp - 01 Set (e) Digital type display multi function meter with parameters like Volts, Amps, Frequency, Power factor, etc - 01 No. (f) LED indication lamp RYB Set of three - 01 No.
Buds school electrification
OD44037/2026-2027:Supply Conveyance, installation, testing and commissioning of 40W LED Flood/ street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be separatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)