Loading…
Loading…
908 results • Best match
Design, Supply, Installation, Testing and Commissioning of Power Management System PMS SCADA based on premise for all Substations 6 Nos at NIT Warangal campus
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of upto 35 sq.mm or laying of OFC cable in HDPE pipe direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
Supply Installation and Testing and Commissioning of Electrical Power Supply System for the Fully Automatic landscape and garden water distribution system near Engineering Halls and VDG at BARC Trombay Mumbai 400085
24C, Single mode Fibre Optic armoured cable
PROVN OF AUDITORIUM 500 CAPCITY AT 58 GTC SHILLONG
Supply, Installation, Testing & Commissioning (SITC) of signal cable shall feature a high-quality PVC jacket with an outer diameter of ø 8.80 mm, presented in marine blue for clear identification and durability. The cable's shielding shall be composed of two layers: Shield No. 1 and Shield No. 2, each constructed with bare copper wires (0.10 mm), providing 100% coverage for optimal signal integrity and protection against electromagnetic interference. The internal structure shall include a polyester nonwoven layer, thermally bonded and coated on both sides with aluminum for enhanced separation and shielding capabilities. A viscose filler material shall provide structural integrity and separation within the cable, ensuring robustness in installation and use.The conductor shield layer shall similarly consist of a polyester nonwoven material, thermally bonded and coated on both sides with aluminum, further bolstering the cable's electromagnetic shielding. The conductive copper shield shall also employ bare copper wires (0.10 mm) with 100% coverage, maintaining the cable's high performance and reliability.The insulation of the cable shall be cellular polyethylene (PE), with an outer diameter of ø 2.00 mm, ensuring excellent dielectric properties and durability. Four distinct colors shall be used for easy conductor identification, facilitating accurate and efficient installation.The conductor material shall consist of stranded bare low-capacitance oxygen-free copper (LCOF) wires, with a configuration of 64 x 0.10 mm strands, yielding a cross-sectional area of 0.50 mm² per conductor.
please refer BOQ
Supply, Drawing and Testing, of stranded Multi mode (50/125 μm) glass optic fiber cable, as per latest ammendments of TIA/EIA 568/ISO/IEC 11801:2011/ IEC 60794-1-2 E1, E3,E11, F1/ EN 50173-1/ EN 187 000/ IEC 60974-2, 2-20, 2-21/ ITU G.652D, construction of LSZH outer sheath cable, cable should be used for LAN and WAN back bones, . With its LSZH sheathing these cables should be ideal for indoor/outdoor installations in existing MS/PVC /HDPE Conduits/ slotted channels with ferruling at both ends for identification complete in all respect. All as per pre approved by Engineer in charge.
please refer BOQ
Supply, Drawing and Testing, of stranded Multi mode (50/125 μm) glass optic fiber cable, as per latest ammendments of TIA/EIA 568/ISO/IEC 11801:2011/ IEC 60794-1-2 E1, E3,E11, F1/ EN 50173-1/ EN 187 000/ IEC 60974-2, 2-20, 2-21/ ITU G.652D, construction of LSZH outer sheath cable, cable should be used for LAN and WAN back bones, . With its LSZH sheathing these cables should be ideal for indoor/outdoor installations in existing MS/PVC /HDPE Conduits/ slotted channels with ferruling at both ends for identification complete in all respect. All as per pre approved by Engineer in charge.
Rajkot division-S&T Work in connection with (i) Providing ROB in lieu of LC No 135 at Km 755/0-1 Between KHDI - PDH section(2 lanes) (ii) Providing ROB in lieu of LC No 147 at Km 770/1-2 Between PDH - CX section(2 lanes) (iii) Proposed LHS in lieu of LC No. 92 at Km 698/1-2 bet LXR-WKR (iv) Kanalus: Rectification of bad layout from Pt 112 towards PBR side by shifting the turnout by 18m towards RJT.
Tool Kit consisting of Optical power meter (Fiber shot 9990V), Multimeter (Fluke101),Ethernet Crimping tool (Standard Make), Console cable (Cisco=RJ45-DB9), Wrist ripper 16 (Standard Make), Universal Spanner Set (Taparia), Screw Driver Set (Taparia-7 Pieces set), Cutting plier (Taparia), Wire Stripper, Industrial grade USB to Serial cable with all accessories or Similar. [Detailed Specification in Technical Document]. Inspection: Consignee (As per technical specification of tender condition)